Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIELECTRIC TRACK DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental and calculated LET distributions in the Cosmos-2044 biosatellite orbit

During the flight of the Cosmos-2044 biosatellite, joint U.S.S.R.-U.S.A. investigations of different characteristics of cosmic radiation (CR) in the near-Earth environment were carried out. The U.S. dielectric track detectors CR-39 and Soviet BYa- and BR-type nuclear photo-emulsions were used as detectors. The present work shows some results of experimental measurements of linear energy transfer (LET) spectra of CR particles obtained with the use of these detectors, which were placed both inside and outside the satellite. The LET spectra measurements with plastic detectors is composed of two parts: the measurement of galactic cosmos rays (GCR) particles, and of short-range particles. The contributions of these components to the total LET distribution at various thicknesses of the shielding were analyzed and the results of these studies are presented. Calculated LET spectra in the Cosmos-2044 orbit were compared with experimental data. On the basis of experimental and calculated values of the LET spectra, absorbed and equivalent CR doses were calculated. In the shielding range of 1-1.5 g cm(exp -2), outside the spacecraft, the photo-emulsions yielded 10.3 mrad d(exp -1) and 13.4 mrem d(exp -1) (LET greater than or equal to 40 MeV cm(exp -1)). Inside the spacecraft (greater than or equal to 10 g cm(exp -2) the photo-emulsions yielded 8.9 mrad d(exp -1) and 14.5 mrem d(exp -1).

Watts, J. W., Jr.↗

Experimental and calculated LET distributions in the Cosmos-2044 biosatellite orbit

During the flight of the Cosmos-2044 biosatellite, joint U.S.S.R.-U.S.A. investigations of different characteristics of cosmic radiation (CR) in the near-Earth environment were carried out. The U.S. dielectric track detectors CR-39 and Soviet BYa- and BR-type nuclear photo-emulsions were used as detectors. The present work shows some results of experimental measurements of linear energy transfer (LET) spectra of CR particles obtained with the use of these detectors, which were placed both inside and outside the satellite. The LET spectra measurement with plastic detectors is composed of two parts: the measurement of galactic cosmic rays (GCR) particles, and of short-range particles. The contributions of these components to the total LET distribution at various thicknesses of the shielding were analyzed and the results of these studies are presented. Calculated LET spectra in the Cosmos-2044 orbit were compared with experimental data. On the basis of experimental and calculated values of the LET spectra, absorbed and equivalent CR doses were calculated. In the shielding range of 1-1.5 g cm-2, outside the spacecraft, the photo-emulsions yielded 10.3 mrad d-1 and 27.5 mrem d-1 (LET > or = 2 MeV cm-1) while the CR-39 yielded averages of 1.43 mrad d-1 and 13.4 mrem d-1 (LET > or = 40 MeV cm-1). Inside the spacecraft (> or = 10 g cm-2) the photo-emulsions yielded 8.9 mrad d-1 and 14.5 mrem d-1.

NASA Program Radiation Health↗

Calibration of the neutron detectors for the cluster fusion experiment on the Texas Petawatt Laser

Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source and 2.45 MeV fusion neutrons generated from laser-cluster interaction were used as neutron sources. The scintillation detectors were calibrated such that they can detect up to 10{sup 8} DD fusion neutrons per shot in current mode under high electromagnetic pulse environments. Indium activation detectors successfully measured neutron yields as low as 10{sup 4} per shot and up to 10{sup 11} neutrons. The use of a Cf-252 neutron source allowed cross calibration of CR-39 and indium activation detectors at high neutron yields ({approx}10{sup 11}). The CR-39 detectors provided consistent measurements of the total neutron yield of Cf-252 when a modified detection efficiency of 4.6 Multiplication-Sign 10{sup -4} was used. The combined use of all three detectors allowed for a detection range of 10{sup 4} to 10{sup 11} neutrons per shot.

43 PARTICLE ACCELERATORS↗

Anomalous radon emission as precursor of medium to strong earthquakes

Anomalous radon (Rn{sup 222}) emissions enhanced by forthcoming earthquakes is considered to be a precursory phenomenon related to an increased geotectonic activity in seismic areas. Rock microfracturing in the Earth’s crust preceding a seismic rupture may cause local surface deformation fields, rock dislocations, charged particle generation and motion, electrical conductivity changes, radon and other gases emission, fluid diffusion, electrokinetic, piezomagnetic and piezoelectric effects as well as climate fluctuations. Space-time anomalies of radon gas emitted in underground water, soil and near the ground air weeks to days in the epicentral areas can be associated with the strain stress changes that occurred before the occurrence of medium and strong earthquakes. This paper aims to investigate temporal variations of radon concentration levels in air near or in the ground by the use of solid state nuclear track detectors (SSNTD) CR-39 and LR-115 in relation with some important seismic events recorded in Vrancea region, Romania.

58 GEOSCIENCES↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LET Spectrum Measurements In CR-39 PNTD With AFM

Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}<10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}<1 {mu}m) following by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features inherently present in the post-etch detector surface. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to 1 GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge changing cross-sections for 300 A MeV Fe{sup 26+} ion beam in Al target

In the present study, total and partial charge changing cross-sections of 300 A MeV Fe{sup 26+} ion beam in Al target were measured. The CR39 nuclear track detectors were used to identify the incident charged particles and their fragments using an automated image analyzer system installed with Leica QWin Plus software. The measured value of the total charge changing cross-section is {sigma}{sub tot}= (1663 {+-} 236) mb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of indoor radon concentrations at the elementary schools of Fatih district in Istanbul

Radon is an odorless, tasteless, colorless noble radioactive gas which is produced within the radioactive decay chain of Uranium. The Radon forms in rocks, diffuses into soil and then escapes into atmosphere. When human exposure to high concentration of radon gas from inside, risk of developing lung cancer is increased. There are many methods to determine {sup 222}Rn concentration in the air. In this study, radon concentration of confined air spaces were measured by using LR-115 solid state nuclear track detectors. 509 LR-115 nuclear trace detectors were placed to 25 schools in Fatih District and they effective dose values were calculated. The results of measurements showed that the radon concentration varies between 40-395 Bq/m{sup 3}. This results compared with Turkey’s limits (400 Bq/m{sup 3}) are low, conversely higher compared with WHO’s limits (100 Bq/m{sup 3}).

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of neutron spectra generated from bombardment of 4 to 24 MeV protons on a thick {sup 9}Be target and estimation of neutron yields

A systematic study on the measurement of neutron spectra emitted from the interaction of protons of various energies with a thick beryllium target has been carried out. The measurements were carried out in the forward direction (at 0° with respect to the direction of protons) using CR-39 detectors. The doses were estimated using the in-house image analyzing program autoTRAK-n, which works on the principle of luminosity variation in and around the track boundaries. A total of six different proton energies starting from 4 MeV to 24 MeV with an energy gap of 4 MeV were chosen for the study of the neutron yields and the estimation of doses. Nearly, 92% of the recoil tracks developed after chemical etching were circular in nature, but the size distributions of the recoil tracks were not found to be linearly dependent on the projectile energy. The neutron yield and dose values were found to be increasing linearly with increasing projectile energies. The response of CR-39 detector was also investigated at different beam currents at two different proton energies. A linear increase of neutron yield with beam current was observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E{sub n} ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C{sup 6+}, O{sup 8+}, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An indoor radon survey of the X-ray rooms of Mexico City hospitals

This paper presents the results of measurements of indoor radon concentrations in the X-ray rooms of a selection of hospitals in the metropolitan area of Mexico City. The metropolitan area of Mexico City is Mexico's largest metropolitan area by population; the number of patients requiring the use of X-rays is also the highest. An understanding of indoor radon concentrations in X-ray rooms is necessary for the estimation of the radiological risk to which patients, radiologists and medical technicians are exposed. The indoor radon concentrations were monitored for a period of six months using nuclear track detectors (NTD) consisting of a closed-end cup system with CR-39 (Lantrack Registered-Sign ) polycarbonate as detector material. The indoor radon concentrations were found to be between 75 and 170 Bq m{sup -3}, below the USEPA-recommended indoor radon action level for working places of 400 Bq m{sup -3}. It is hoped that the results of this study will contribute to the establishment of recommended action levels by the Mexican regulatory authorities responsible for nuclear safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using {sup 222}Rn as a tracer of geophysical processes in underground environments

Radon levels in two old mines in San Luis, Argentina, are reported and analyzed. These mines are today used for touristic visitation. Our goal was to assess the potential use of such radioactive noble gas as tracer of geological processes in underground environments. CR-39 nuclear track detectors were used during the winter and summer seasons. The findings show that the significant radon concentrations reported in this environment are subject to large seasonal modulations, due to the strong dependence of natural ventilation on the variations of outside temperature. The results also indicate that radon pattern distribution appear as a good method to localize unknown ducts, fissures or secondary tunnels in subterranean environments.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty evaluation for the matrix 'solidified state' of fissionable elements

In case of the analysis of the radioactive liquid samples, no matter the relative physical analysis method used, two impediments act that belong to the behavior in time of the dispersion state of the liquid samples to be analyzed and of the standard used in the analysis. That is, one of them refers to the state of the sample to be analyzed when being sampled, which 'alter' during the time elapsed from sampling up to the analysis of the sample. The other impediment is the natural change of the dispersion state of the standard radioactive solutions, due to the occurrence and evolution in time of the radiocolloidal and pseudo-radiocolloidal states. These radiocolloidal states are states of aggregation and they lead to the destruction of the homogeneity of the solutions. Taking into consideration the advantages offered by the relative physical methods of analysis as against the chemical or the radiochemical ones, different ways of eliminating these impediments have been tried. We eliminated these impediments processing the liquid reference materials (the solutions calibrated in radionuclides of interest), immediately after the preparation. This processing changes the liquid physical state of the reference materials in a 'solidified state'. Through this procedure the dispersion states of the samples, practically, can no longer be essentially modified in time and also ensure the uniform distribution of the radionuclides of interest in the elemental matrix of the samples 'state solidified'. The homogeneity of the distribution of the atoms of the radionuclides from the samples 'solidified state' was checked up through the track micromapping technique of the alpha particles. Through this technique, in the chemically etched track detectors that were put in direct contact with the sample for a determined period of time, the alpha exposure time of the detectors, micromaps of alpha tracks were obtained. These micromaps are retorts through tracks of the distributions atoms of fissionable elements (Thorium e.g.), of which, heavy charged particles, in this case the alpha radiations naturally emitted, were registered in the CR-39 track detectors. The density of alpha track from the obtained track micromaps was studied through common optic microscopy. Micromaps were studied counting the tracks on equal areas, in different measurement points. For the study of the foils prepared within the paper, the studied area was of 4.9 mm2, formed of 10 fields of 0.49 mm2 area each. The estimation of the uncertainty was carried out for all the sizes that were measured within the paper, no matter if they participate, directly or indirectly, in the estimation of the uncertainty regarding the homogeneity of the Thorium atoms distribution in the 'solidified state' foils of the standard solution calibrated in Thorium, such as: i) the weighted masses, ii) the dropped volumes of solution, iii) the alpha duration of exposure of the detectors, iv) the area studied on the surface of the micromap and v) the densities of alpha tracks. The procedure suggested allowed us to considerate that the homogeneity of alpha tracks distribution, on the surface and in thickness, is within the limits of 3.1%.

36 MATERIALS SCIENCE↗

New tracking system of the SND detector

A new tracking system (TS) of the Spherical Neutral Detector (SND) for experiments at the VEPP-2000 e{sup +}e{sup -} collider is described. The TS is completely assembled, mounted on the detector, and ready for collecting data from the VEPP-2000. Test experiments with cosmic-ray events and VEPP-2000 beams showed a stable operation of the system. The simulation, calibration, and reconstruction procedures were debugged by using available data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution Thomson parabola for ion analysis

A new, versatile Thomson parabola ion energy (TPIE) analyzer has been designed, constructed, and used at the OMEGA-EP facility. Laser-accelerated multi-MeV ions from hemispherical C targets are transmitted through a W pinhole into a multi-kG magnetic field and subsequently through a parallel electric field of up to 25 kV/cm. The ion drift region has a user-selected length of 10, 50, or 80 cm. With the highest fields, 400-MeV C{sup 6+} and C{sup 5+} may be resolved. TPIE is ten-inch manipulator (TIM)-mounted at OMEGA-EP and can be used opposite either of the EP ps beams. The instrument runs on pressure-interlocked 15-Vdc power available in EP TIM carts. Flux control derives from the insertion depth into the target chamber and the user-selected pinhole dimensions. The detector consists of CR39 backed by an image plate. A fully relativistic simulation code for calculating ion trajectories was employed for design optimization. Excellent agreement of code predictions with the actual ion positions on the detectors is observed. Through pit counting of carbon-ion tracks in CR39, it is shown that conversion efficiency of laser light to energetic carbon ions exceeds {approx}5% for these targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗