Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIFFUSION CHAMBERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new thermal gradient ice nucleation diffusion chamber instrument: design, development and first results using Saharan mineral dust

A new Thermal Gradient ice nucleation Diffusion Chamber (TGDC) capable of investigating ice nucleation efficiency of atmospherically important aerosols, termed Ice Nuclei (IN), has been designed, constructed and validated. The TGDC can produce a range of supersaturations with respect to ice (SSi) over the temperature range of -10 to -34°C for sufficiently long time needed to observe the nucleation by the particles. The aerosol particles under examination were supported on a Teflon substrate and nucleation events observed using digital photography. The TGDC consists of two ice coated plates to which a thermal gradient is applied to produce the range of SSi. The ability to understand time-related ice nucleation event information and to perform experiments at different temperatures and SSi conditions for different IN without changing the thermal gradient makes the TGDC a unique ice nucleation chamber. The SSi and temperature conditions of the experimental system are validated by observing (NH4)2SO4 deliquescence and the results are in good agreement with the literature data. The design details of the TGDC along with the experimental set-up, the experimental procedure and its usefulness in understanding ice nucleation processes of dust particles are presented. The ice nucleation investigations using different particles are needed to better quantify the role of ice formation in the atmosphere.

47 OTHER INSTRUMENTATION↗

Radon detection in conical diffusion chambers: Monte Carlo calculations and experiment

The operation of radon detection diffusion chambers of truncated conical shape was studied using Monte Carlo calculations. The efficiency was studied for alpha particles generated randomly in the volume of the chamber, and progeny generated randomly on the interior surface, which reach track detectors placed in different positions within the chamber. Incidence angular distributions, incidence energy spectra and path length distributions are calculated. Cases studied include different positions of the detector within the chamber, varying atmospheric pressure, and introducing a cutoff incidence angle and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of natural ice nuclei with a continuous flow diffusion chamber

A description is given of a continuous flow diffusion chamber technique for measuring the atmospheric concentrations of natural C-F nuclei. It is noted that the same device can also measure deposition nuclei; these two modes can thus be separated and compared. The laminar flow characteristics allow the temperature and supersaturation to be calculated with a high degree of precision and confidence. The method avoids the problems of a supporting substrate and of concentrating the sample into a small volume (as for membrane filters). The present measurements of natural ice nucleus concentrations at +1 percent water supersaturation are found to be comparable to research aircraft measurements of ice crystal concentrations in winter cap clouds over Elk Mountain, Wyoming (Vali et al., 1982).

Rogers, D. C.↗

Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ice crystal growth in a dynamic thermal diffusion chamber

Ice crystals were grown in a supersaturated environment produced by a dynamic thermal diffusion chamber, which employed two horizontal plates separated by a distance of 2.5 cm. Air was circulated between and along the 1.2 m length of the plates past ice crystals which nucleated and grew from a fiber suspended vertically between the two plates. A zoom stereo microscope with a magnification which ranged from 3X to 80X and both 35 mm still photographs and 16 mm time lapse cine films taken through the microscope were used to study the variation of the shape and linear growth rate of ice crystals as a function of the ambient temperature, the ambient supersaturation, and the forced ventilation velocity. The ambient growth conditions were varied over the range of temperature 0 to -40 C, over the range of supersaturation 4% to 50% with respect to ice, and over the range of forced ventilation velocities 0 cm/s to 20 cm/s.

Keller, V. W.↗

Metagenomic Evaluation of Bacterial and Fungal Assemblages Enriched within Diffusion Chambers and Microbial Traps Containing Uraniferous Soils

Despite significant technological advancements in the field of microbial ecology, cultivation and subsequent isolation of the vast majority of environmental microorganisms continues to pose challenges. Isolation of the environmental microbiomes is prerequisite to better understand a myriad of ecosystem services they provide, such as bioremediation of contaminants. Towards this end, in this culturomics study, we evaluated the colonization of soil bacterial and fungal communities within diffusion chambers (DC) and microbial traps (MT) established using uraniferous soils collected from a historically contaminated soil from Aiken, USA. Microbial assemblages were compared between the DC and MT relative to the native soils using amplicon based metagenomic and bioinformatic analysis. The overall rationale of this study is that DC and MT growth chambers provide the optimum conditions under which desired microbiota, identified in a previous study to serve as the “core” microbiomes, will proliferate, leading to their successful isolation. Specifically, the core microbiomes consisted of assemblages of bacteria (Burkholderia spp.) and fungi (Penicillium spp.), respectively. The findings from this study further supported previous data such that the abundance and diversity of the desired “core” microbiomes significantly increased as a function of enrichments over three consecutive generations of DC and MT, respectively. Metagenomic analysis of the DC/MT generations also revealed that enrichment and stable populations of the desired “core” bacterial and fungal microbiomes develop within the first 20 days of incubation and the practice of subsequent transfers for second and third generations, as is standard in previous studies, may be unnecessary. As a cost and time cutting measure, this study recommends running the DC/MT chambers for only a 20-day time period, as opposed to previous studies, which were run for months. In summation, it was concluded that, using the diffusion chamber-based enrichment techniques, growth of desired microbiota possessing environmentally relevant functions can be achieved in a much shorter time frame than has been previously shown.

Jaswal, Rajneesh (ORCID:0000000217841805)↗

Modification of the continuous flow diffusion chamber for use in zero-gravity

The design philosophy and performance characteristics of the continuous flow diffusion chamber developed for use in ground-based simulation of some of the experiments planned for the atmospheric cloud physics laboratory during the first Spacelab flight are discussed. Topics covered include principle of operation, thermal control, temperature measurement, tem-powered heat exchangers, wettable metal surfaces, sample injection system, and control electronics.

Keyser, G.↗

CCN comparisons of static diffusion chambers

Nine CCN counters of the static diffusion (SDC) type were compared with one another and with continuous flow diffusion (CFD) chambers. The nine SDCs showed a considerable amount of variation, largely attributable to newness and/or lack of prior calibration of some units. The five more consistent instruments agreed quite well, to within at least 20 percent of the NRL mobility analyzer and to within 10 percent at 1 percent supersaturation. There was satisfactory agreement between the more reliable SDC and CFD chambers.

Jiusto, J. E.↗

Uncertainty in counting ice nucleating particles with continuous flow diffusion chambers

Abstract. This study investigates the measurement of ice nucleating particle (INP) concentrations and sizing of crystals using continuous flow diffusion chambers (CFDCs). CFDCs have been deployed for decades to measure the formation of INPs under controlled humidity and temperature conditions in laboratory studies and by ambient aerosol populations. These measurements have, in turn, been used to construct parameterizations for use in models by relating the formation of ice crystals to state variables such as temperature and humidity as well as aerosol particle properties such as composition and number. We show here that assumptions of ideal instrument behavior are not supported by measurements made with a commercially available CFDC, the SPectrometer for Ice Nucleation (SPIN), and the instrument on which it is based, the Zurich Ice Nucleation Chamber (ZINC). Non-ideal instrument behavior, which is likely inherent to varying degrees in all CFDCs, is caused by exposure of particles to different humidities and/or temperatures than predicated from instrument theory of operation. This can result in a systematic, and variable, underestimation of reported INP concentrations. We find here variable correction factors from 1.5 to 9.5, consistent with previous literature values. We use a machine learning approach to show that non-ideality is most likely due to small-scale flow features where the aerosols are combined with sheath flows. Machine learning is also used to minimize the uncertainty in measured INP concentrations. We suggest that detailed measurement, on an instrument-by-instrument basis, be performed to characterize this uncertainty.

54 ENVIRONMENTAL SCIENCES↗

AEROICESTUDY Colorado State University Continuous Flow Diffusion Chamber (CFDC) version R0

This dataset comprises measurements of atmospheric ice nucleating particle (INP) number concentrations at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the 2019 Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). The results reported here are from the Colorado State University Continuous Flow Diffusion Chamber (CFDC-1H) and represent real-time measurements of ambient INPs.

54 ENVIRONMENTAL SCIENCES↗

A new method for operating a continuous flow diffusion chamber to investigate immersion freezing: assessment and performance study

Glaciation in mixed-phase clouds predominately occurs through the immersion freezing mode where ice nucleating particles (INPs) immersed within supercooled droplets induce nucleation of ice. Currently, model representations of this process are a large source of uncertainty in simulating cloud radiative properties, and to constrain these estimates, continuous flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion freezing efficiencies of INPs. In this study, a new approach was explored to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that has not been demonstrated as possible previously. The conditioning section of the chamber was maintained at ~ –20 °C and water relative humidity (RH w ) ~ 113 % conditions to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 °C min –1 ) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified ice chamber was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne arable dust that had shown ice nucleation over a wide span of supercooled temperatures. Dry dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne arable dust particles were sampled from the aerosol inlet located on the rooftop of the laboratory. The measured ice nucleation efficiencies of model aerosols with a surface active site density (n s ) metric were higher, but mostly agreed within one order of magnitude compared to literature results.

54 ENVIRONMENTAL SCIENCES↗

A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: assessment and performance study

Abstract. Glaciation in mixed-phase clouds predominantly occurs through the immersion-freezing mode where ice-nucleating particles (INPs) immersed within supercooled droplets induce the nucleation of ice. Model representations of this process currently are a large source of uncertainty in simulating cloud radiative properties, so to constrain these estimates, continuous-flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion-freezing efficiencies of INPs. This study explored a new approach to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that previously had not been demonstrated to be possible. The conditioning section of the chamber was maintained at −20 ∘C and water relative humidity (RHw) conditions of 113 % to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 ∘C min−1) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified compact ice chamber (MCIC) was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne soil dusts from an arable region that had shown ice nucleation over a wide span of supercooled temperatures. Dry-dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne soil dust particles were sampled from an ambient aerosol inlet. The measured ice nucleation efficiencies of model aerosols that had a surface active site density (ns) metric were higher but mostly agreed within 1 order of magnitude compared to results reported in the literature.

54 ENVIRONMENTAL SCIENCES↗

Forced Diffusion Chamber Monitoring of Soil CO2 Fluxes from 2019 to Present at NGEE Arctic Teller Site, Mile Marker 27, Alaska

Soil CO2 efflux was monitored at the NGEE Arctic Teller Site, Mile Marker 27, in Alaska. Monitoring was performed beginning in June 2019 using EOSense forced diffusion soil CO2 flux sensors at up to six sites characterized by varying vegetation cover, topographic position, and soil temperature and moisture. Dataset includes measurements of soil CO2 flux and chamber temperature. Time interval between measurements ranges from 5 minutes to 3 hours. Included are EOSense chamber locations as *.kml and *.png files, six *.csv files with measurements, and two *.csv reporting format files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Performance of the continuous flow diffusion chambers

A brief comparative description is made of the chambers. Overall, comparisons for the various types of experiments - monodisperse, polydisperse and ambient aerosol - showed agreement among these chambers to within 15% in most cases. A careful analysis of the results indicated that a proper accounting of certain parameters would bring about much closer agreement among four of these instruments.

Hudson, J. G.↗

Plane and hemispherical potential structures in magnetically expanding plasmas

Two-dimensional potential structures are measured for different gas pressure in expanding argon plasma using permanent magnets, where the magnetic field is about 100 G in the source and several gauss in the diffusion chamber. The plane potential drop is observed near the source exit for 0.35 mTorr, while the potential structure becomes hemispherical when increasing up to 1 mTorr; the hemispherical structure results in the radial divergence of the ion beam. It is found that the trajectories of the accelerated ions and the electrons overcoming the potential drop are dominated by the potential structure and magnetic-field lines, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Atmospheric Cloud Physics Laboratory for the Space Laboratory

Results of research and engineering analyses to date show that it is feasible to develop and fly on the first Spacelab mission a multipurpose laboratory in which experiments can be performed on the microphysical processes in atmospheric clouds. The paper presents a series of tables on the Atmospheric Cloud Physics Laboratory, with attention given to experiment classes, the preliminary equipment list (particle generators, optical and imaging devices, particle detectors and characterizers, etc.), initial equipment (scientific equipment subsystems and flight support subsystems), and scientific functional requirements (the expansion chamber, the continuous flow diffusion chamber, the static diffusion chamber, the humidifier, and particle generators).

Smith, R.↗