Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIP update”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021 Version 2.0

This submission includes an update to the WHOLESCALESamples2021January.xls file where the strikes and dips initially reported have been corrected to comply with the right hand rule. The updated excel file and a link to the original submission are included in this report. The original submission "WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021" contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

Bubbler Design Updates for Nuclear Safeguards Applications

The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bubbler Design Updates for Nuclear Safeguards Application

The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RHIC Run 22, 9 o'clock, a Snake in the Blue

The simulations detailed in this Tech. Note were aimed at determining new RHIC Blue 9 o’clock snake coil current and local closed orbit bump settings, together with updated - optimized - 3 o’clock snake settings, in order to recover from power supply dips which, early in the run (December 2021), caused the failure of 9 o’clock snake’s second coil in a first occurrence, and of its fourth coil in addition in a second occurrence, leaving the poor animal with just its coils 1 and 3. Documentation from a similar incident in Yellow in 2003 could be leaned on and allowed to promptly figure various necessary measures for swift recovery using the 9 o’clock Blue snake coils which survived the dip. Reference reports in particular that, in this 2003 incident, “[it was] decided to run the [failed] snake as a 88% partial snake while keeping the angles between the two snakes as 90° [...]. In general, the polarization level was not as good as Blue ring”. By contrast in this Run 22 incident, thorough simulations using the snake OPERA field maps helped determine new settings of the handicapped, 2-coil, Blue ring 9 o’clock snake currents and local closed orbit bump, and concurrently determine slight adjustment of the 3 o’clock snake currents, which allowed recovering full polarization at store, as good as could be expected from normal operation - even better over extended periods than in the Yellow ring.

43 PARTICLE ACCELERATORS↗

Application of a Triple Bubbler Inside Molten Salt for Pyroprocessing Safeguards Purposes

The application of a triple bubbler system within molten salt environments, specifically a eutectic mixture of LiCl-KCl, is explored for nuclear safeguards purposes, focusing on nuclear material accountancy (NMA) and holdup accountancy in pyroprocessing techniques. Traditional holdup accountancy methods, which involve periodic sampling and lengthy lead times, are being supplemented by the development of actinide sensors using electrochemistry. However, these methods alone are insufficient to meet regulatory requirements set by agencies like NRC and IAEA. The triple bubbler device measures salt level, density, and surface tension simultaneously using three dip tubes of varying diameters and heights. This study investigates the accuracy and robustness of the triple bubbler in molten salt conditions at temperatures ranging from 450-550°C. The updated bubbler design, utilizing tantalum metal and larger tube geometry, demonstrated minimal plugging and maintained measurement accuracy within acceptable uncertainties: 0.611% for depth, 1.34% for density, and approximately 40% for surface tension. Results indicate that the triple bubbler system is effective for real-time, accurate measurements in pyroprocessing environments, making it a promising tool for ensuring compliance with nuclear safeguards and supporting nuclear non-proliferation efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

M31N 2008-12a—the remarkable recurrent nova in M31: panchromatic observations of the 2015 eruption

The Andromeda Galaxy recurrent nova M31N 2008-12a had been observed in eruption 10 times, including yearly eruptions from 2008 to 2014. With a measured recurrence period of P{sub rec}=351±13 days (we believe the true value to be half of this) and a white dwarf very close to the Chandrasekhar limit, M31N 2008-12a has become the leading pre-explosion supernova type Ia progenitor candidate. Following multi-wavelength follow-up observations of the 2013 and 2014 eruptions, we initiated a campaign to ensure early detection of the predicted 2015 eruption, which triggered ambitious ground- and space-based follow-up programs. In this paper we present the 2015 detection, visible to near-infrared photometry and visible spectroscopy, and ultraviolet and X-ray observations from the Swift observatory. The LCOGT 2 m (Hawaii) discovered the 2015 eruption, estimated to have commenced at August 28.28 ± 0.12 UT. The 2013–2015 eruptions are remarkably similar at all wavelengths. New early spectroscopic observations reveal short-lived emission from material with velocities ∼13,000 km s{sup −1}, possibly collimated outflows. Photometric and spectroscopic observations of the eruption provide strong evidence supporting a red giant donor. An apparently stochastic variability during the early supersoft X-ray phase was comparable in amplitude and duration to past eruptions, but the 2013 and 2015 eruptions show evidence of a brief flux dip during this phase. The multi-eruption Swift/XRT spectra show tentative evidence of high-ionization emission lines above a high-temperature continuum. Following Henze et al. (2015a), the updated recurrence period based on all known eruptions is P{sub rec}=174±10 days, and we expect the next eruption of M31N 2008-12a to occur around 2016 mid-September.

79 ASTRONOMY AND ASTROPHYSICS↗

CO 2 plume evolution in a depleted natural gas reservoir: Modeling of conformance uncertainty reduction over time

Uncertainty in the long-term fate of CO 2 injected for geologic carbon sequestration (GCS) is a significant barrier to the adoption of GCS as a greenhouse-gas emission-mitigation for industry and regulatory agencies alike. Here, we present a modeling study that demonstrates that the uncertainty in forecasts of GCS site performance decreases over time as monitoring data are used to update operational models. We consider a case study of GCS in a depleted natural gas reservoir, with CO 2 injection occurring over 20 years, with a 50-year post-injection site care period. We constructed a detailed model to generate the actual model output, which is considered synthetic observation data. A series of simpler operational models based on limited data and assumptions about how an operator would model such a site are then run and compared against actual model output at specific monitoring points after one year, two years, etc. The operational model is updated and improved using the synthetic observation data from the actual model at the same time intervals. Model parameter values and model features needed to be updated over time to improve matches to the actual model. These kinds of model adjustments would be a normal part of reservoir engineering and site management at GCS sites. Uncertainty in two key measures related to site performance decreases with time: extent of the CO 2 plume up-dip migration, and radial extent of the pressure pulse. This conclusion should help allay the concerns of industry and regulators about uncertainty in long-term fate of CO 2 at GCS sites.

54 ENVIRONMENTAL SCIENCES↗

Bubbler Design Updates for Nuclear Safeguards Applications

The accurate monitoring of molten salt compositions is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors as well as pyroprocessing. However, for nuclear material accountancy in actinide bearing molten salts, the solution volume is also needed to determine the total mass of material in the salt. This study explores the effectiveness of two bubbler configurations, triple and single, for density and level measurements within these molten salts for salt volume determinations. The triple bubbler system utilizes three gas dip-tubes strategically positioned at different heights within the molten salt. With this design, the molten salt level, density, and surface tension can be determined simultaneously. The single bubbler configuration, on the other hand, relies on a dynamic single dip-tube to determine the density and level. Both configurations will be tested in aqueous solutions as well as in LiCl-KCl and NaCl-MgCl2 molten salts between 450°C and 750°C. Dip-tube diameters and bubbler inferences will also be explored. A new bubbler is being designed based on results. The findings of this study will provide valuable insights into the optimal bubbler design and configuration for ensuring representative sampling of molten salt compositions in nuclear safeguards applications. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting nuclear safeguards objectives.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3XMM J185246.6+003317: ANOTHER LOW MAGNETIC FIELD MAGNETAR

We study the outburst of the newly discovered X-ray transient 3XMM J185246.6+003317, re-analyzing all available XMM-Newton observations of the source to perform a phase-coherent timing analysis, and derive updated values of the period and period derivative. We find the source rotating at P = 11.55871346(6) s (90% confidence level; at epoch MJD 54728.7) but no evidence for a period derivative in the seven months of outburst decay spanned by the observations. This translates to a 3σ upper limit for the period derivative of P-dot <1.4×10{sup −13} s s{sup –1}, which, assuming the classical magneto-dipolar braking model, gives a limit on the dipolar magnetic field of B {sub dip} < 4.1 × 10{sup 13} G. The X-ray outburst and spectral characteristics of 3XMM J185246.6+003317 confirm its identification as a magnetar, but the magnetic field upper limit we derive defines it as the third ''low-B'' magnetar discovered in the past 3 yr, after SGR 0418+5729 and Swift J1822.3–1606. We have also obtained an upper limit to the quiescent luminosity (<4 × 10{sup 33} erg s{sup –1}), in line with the expectations for an old magnetar. The discovery of this new low field magnetar reaffirms the prediction of about one outburst per year from the hidden population of aged magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Updated FMI Fracture Log from Well 16A(78)-32

This dataset consists of an Excel spreadsheet detailing the fracture picks from a reinterpretation of the formation micro-imaging (FMI) log from Utah FORGE well 16A(78)-32. The provided information details fracture location, geometry, and type. Also included here is a link to the original raw and processed FMI logs, as well as other data from the 2021 well logging.

15 GEOTHERMAL ENERGY↗

Efficient 3-D velocity model building using joint inline and crossline plane-wave wave-equation migration velocity analyses

SUMMARY Wave-equation migration velocity analysis (WEMVA) is an image-domain inversion method for velocity model building. Automatic plane-wave WEMVA (PWEMVA) calculates the moveouts of plane-wave common-image gathers (CIGs) by searching a best-fitting parabola with semblance analysis and backprojects residual CIG moveouts into wavefield wave paths with a reflection tomographic kernel. However, 3-D PWEMVA is very computationally expensive because 3-D reflection tomographic inversion requires at least five 3-D reverse-time migrations per iteration and stores two types of source wavefields at model boundaries. We develop a joint inline and crossline PWEMVA method for efficient 3-D velocity model building. We alternatively implement the inline and crossline PWEMVAs with a constraint for each other, in which we iteratively construct the 3-D velocity model update through 1-D spline interpolation of 2-D gradients. The inline and crossline joint inversion is practical since PWEMVA only inverts for low-wavenumber velocity perturbations along wave paths, and the method can take less than 1 per cent of the computational cost of full 3-D PWEMVA. To construct unaliased plane waves for our joint inline and crossline PWEMVA, we develop a 3-D data interpolation method in the frequency–wavenumber (FK) domain to recover regularly and randomly missing traces. The method minimizes the misfit on sufficiently localized data subsets with iterative optimal step lengths and a gradient preconditioner that iteratively selects dominant dips along different azimuths. In numerical experiments, we use a 3-D synthetic seismic data set and a land 3-D field seismic data set acquired at the Farnsworth CO2-EOR (enhanced oil recovery) field to demonstrate the efficacy of our velocity model building and data interpolation methods.

Liu, Xuejian↗

AN Fe XXIV ABSORPTION LINE IN THE PERSISTENT SPECTRUM OF THE DIPPING LOW-MASS X-RAY BINARY 1A 1744-361

We report on Chandra X-ray Observatory (Chandra) High Energy Transmission Grating spectra of the dipping low-mass X-ray binary 1A 1744-361 during its 2008 July outburst. We find that its persistent emission is well modeled by a blackbody (kT {approx} 1.0 keV) plus power law ({Gamma} {approx} 1.7) with an absorption edge. In the residuals of the combined spectrum, we find a significant absorption line at 6.961 {+-} 0.002 keV, consistent with the Fe XXVI (hydrogen-like Fe) 2-1 transition. We place an upper limit on the velocity of a redshifted flow of v < 221 km s{sup -1}. We find an equivalent width for the line of 27{sup +2}{sub -3} eV, from which we determine a column density of (7 {+-} 1) Multiplication-Sign 10{sup 17} cm{sup -2} via a curve-of-growth analysis. Using XSTAR simulations, we place a lower limit on the ionization parameter of >10{sup 3.6} erg cm s{sup -1}. We discuss what implications the feature has on the system and its geometry. We also present Rossi X-ray Timing Explorer data accumulated during this latest outburst and, via an updated color-color diagram, clearly show that 1A 1744-361 is an 'atoll' source.

79 ASTRONOMY AND ASTROPHYSICS↗