Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

Efficient bi-directional coupling of 3D computational fluid-particle dynamics and 1D Multiple Path Particle Dosimetry lung models for multiscale modeling of aerosol dosimetry

The development of predictive aerosol dosimetry models has been a major focus of environmental toxicology and pharmaceutical health research for decades. One-dimensional (1D) models successfully predict overall deposition averages but fail to accurately predict local deposition. Computational fluid-particle dynamics (CFPD) models provide site-specific predictions but at a computational cost that prohibits whole lung predictions. Thus, there is a need for developing multiscale strategies to provide a realistic subject-specific picture of the fate of inhaled aerosol in the lungs. CT-based 3D/CFPD models of the large airways were bidirectionally coupled with individualized 1D Navier-Stokes airflow and particle transport based upon the widely used Multiple Path Particle Dosimetry Model (MPPD). Distribution of airflows among lobes was adjusted by measured lobar volume changes observed in CT images between FRC and FRC + 1.5 L. Additionally, as a test of the effectiveness of the coupling procedures, deposition modeling of previous 1 µm aerosol exposure studies was performed. The complete coupled model was run for 3 breaths, with the computation-intense portion being the 3D CFD Lagrangian particle tracking calculation. The average deposition per breath was 11% in the combined multiscale model with site-specific doses available in the CFPD portion of the model and airway- or region-specific deposition available for the MPPD portion. In conclusion, the key methods developed in this study enable predictions of ventilation heterogeneities and aerosol deposition across the lungs that are not captured by 3D or 1D models alone. Overall, these methods can be used as the foundation for multi-scale modeling of the full respiratory system.

60 APPLIED LIFE SCIENCES↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175C: Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 175C

Results of neutron dosimetry measurements in ATR for cycle 175C are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Building a predictive model for polycyclic aromatic hydrocarbon dosimetry in organotypically cultured human bronchial epithelial cells using benzo[ a ]pyrene

The airway epithelium is a primary route of exposure for inhaled toxicants, and organotypic culture models represent an important advancement for toxicity testing compared to simple in vitro models that may lack metabolic capability and multicellular structure/communication associated with the bronchial epithelium in vivo. A quantitative understanding of chemical dosimetry is key for interpreting and extrapolating study results; however, dosimetry is understudied in organotypic models limiting ability to predict toxicity. We developed a dosimetry model for primary human bronchial epithelial cells (HBECs) cultured at the air-liquid interface (ALI) using benzo[a]pyrene (BAP), a representative polycyclic aromatic hydrocarbon. Dose and time course evaluation of metabolite formation and enzyme activity and expression were utilized to parameterize a cellular dosimetry model to improve the utility of ALI-HBECs for assessing chemical risk. Dosimetry analysis demonstrated absorption of BAP into cells and an increase in Phase 1 and 2 metabolites over time that correlated with regulation of metabolizing enzymes. BAP was cleared from cells by 48 h after exposure, and the primary metabolites generated in ALI-HBECs were BAP-3-phenol, BAP-4,5-dihydrodiol, BAP-7,8-dihydrodiol, BAP-9,10-dihydrodiol, BAP-7,8,9,10-tetrol, BAP-3-phenol-glucuronide, BAP-4,5-dihydrodiol-glucuronide, and BAP-9,10-dihydrodiol-glucuronide. The resulting dosimetry model described BAP and 7,8-dihydrodiol toxicokinetics in ALI-HBECs and suggested active excretion of 7,8-dihydrodiol. Overall, this study demonstrates metabolic competency of ALI-HBECs for BAP metabolism, demonstrates the usefulness of complex in vitro systems for human-relevant toxicity data, and exhibits how in silico models can be utilized for understanding the dosimetry of test compounds to aid in in vitro to human extrapolation of toxicity data for risk assessments.

Benzo[a]pyrene↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗

Fundamentals of wildlife dosimetry and lessons learned from a decade of measuring external dose rates in the field

Methods for determining the radiation dose received by exposed biota require major improvements to reduce uncertainties and increase precision. We share our experiences in attempting to quantify external dose rates to free-ranging wildlife using GPS-coupled dosimetry methods. The manuscript is a primer on fundamental concepts in wildlife dosimetry in which the complexities of quantifying dose rates are highlighted, and lessons learned are presented based on research with wild boar and snakes at Fukushima, wolves at Chornobyl, and reindeer in Norway. GPS-coupled dosimeters produced empirical data to which numerical simulations of external dose using computer software were compared. Our data did not support a standing paradigm in risk analyses: Using averaged soil contaminant levels to model external dose rates conservatively overestimate the dose to individuals within a population. Following this paradigm will likely lead to misguided recommendations for risk management. The GPS-dosimetry data also demonstrated the critical importance of how modeled external dose rates are impacted by the scale at which contaminants are mapped. When contaminant mapping scales are coarse even detailed knowledge about each animal’s home range was inadequate to accurately predict external dose rates. Importantly, modeled external dose rates based on a single measurement at a trap site did not correlate to actual dose rates measured on free ranging animals. These findings provide empirical data to support published concerns about inadequate dosimetry in much of the published Chernobyl and Fukushima dose-effects research. Furthermore, our data indicate that a huge portion of that literature should be challenged, and that improper dosimetry remains a significant source of controversy in radiation dose-effect research.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Historic Architectural Resource Survey of the Dosimetry Applications Research (DOSAR) Facility in the 7700 Area of the Oak Ridge National Laboratory

In May 2022, Cultural Resource Analysts, Inc., completed a historic architectural resource survey of buildings associated with the Dosimetry Applications Research Facility at the Oak Ridge National Laboratory. The laboratory is one of three Department of Energy facilities located on the Oak Ridge Reservation in Roane and Anderson Counties, Tennessee. The Dosimetry Applications Research Facility is located approximately 2 mi southeast of the main Oak Ridge National Laboratory campus. The survey included Buildings 7709, 7710, and 7712, which date to the 1960s. An additional DOSAR building (Building 7735) dates to the late 1980s and was not surveyed since it is outside the period of significance. The survey was conducted at the request of UT-Battelle, LLC, on behalf of the Department of Energy. As stipulated by the National Historic Preservation Act of 1966, as amended, the Department of Energy is required to identify any properties under its jurisdiction that are included in or eligible for inclusion in the National Register of Historic Places. In order to identify historic properties at the Oak Ridge National Laboratory, in 2017–2018 Cultural Resource Analysts, Inc., conducted a survey of the main campus as well as outlying facilities, publishing the findings in a 2018 report entitled Oak Ridge National Laboratory Historic Architectural Resource Survey. At the time of the 2017–2018 survey, buildings associated with the Dosimetry Applications Research Facility were not accessible for security reasons and the current report serves as an addendum to the 2018 report. In addition, the current survey incorporates information included in a documentation report on Building 7709 completed in 2019. The properties included in the current survey were also evaluated for their collective potential as a historic district. The identification of archaeological properties that are eligible for inclusion in the National Register of Historic Places is beyond the scope of this report. Cultural Resource Analysts, Inc., recommends that none of the buildings surveyed for the current report are individually eligible for listing in the National Register of Historic Places. However, the collective of buildings represents a facility that made notable contributions to the Oak Ridge National Laboratory’s scientific research endeavors from the 1960s to the 1980s, specifically in the field of Health Physics. The buildings and their associated features have also maintained their integrity of setting, materials, design, location, and association. Therefore, Cultural Resource Analysts, Inc., proposes the Dosimetry Applications Research Facility Historic District, which is recommended eligible for listing under Criterion A. The three buildings addressed in the current survey (Buildings 7709, 7710, and 7712) are recommended eligible as contributing resources of the historic district. The district boundary is scribed to incorporate the environs of these three facilities, as well as additional relevant features.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA: Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects, etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in-vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose-response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-I) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA-Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-1) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗