Full-Scale Assembly 30 cm Drop Test

Can Spent Nuclear Fuel withstand the shocks and vibrations experienced during normal conditions of transport? This question was the motivation for the multi-modal transportation test (MMTT) (Summer 2017), 1/3-scale cask 30 cm drop test (December 2018), and full-scale assembly 30 cm drop tests (June 2019). The full-scale ENSA ENUN 32P cask with 3 surrogate 17x17 PWR assemblies was used in the MMTT. The 1/3-scale cask was a mockup of this cask. The 30 cm drop tests provided the accelerations on the 1/3-scale dummy assemblies. These data were used to design full-scale assembly drop tests with the goal to quantify the strain fuel rods experience inside a cask when dropped from a height of 30 cm. The drop tests were first done with the dummy and then with the surrogate assembly. This paper presents the preliminary results of the tests.

Transportation↗

Surrogate Assembly 30 cm Drop Test

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. While obtaining data on the actual fuel is not a direct requirement, it provides definitive information which aids in quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. The 30 cm drop test with the full-scale surrogate assembly conducted in May 2020 was the last step needed for quantifying the strains on the surrogate assembly rods under NCT. The full-scale surrogate assembly used in the 2020 30 cm drop test was built using a new 17x17 Pressurized Water Reactor (PWR) Westinghouse skeleton filled with the copper rods and 3 zircaloy rods from the full-scale surrogate assembly used in the Multi-Modal Transportation Test (MMTT). Felt pads were attached to the surrogate assembly bottom prior to the 30 cm drop to adequately represent the effects of the impact limiters and the cask. Note that felt "programming material" has been used extensively in past drop tests and is known to be a good material for programming a desired shock pulse. The felt pad configuration was determined during a previous series of tests reported in. The acceleration pulses observed on the surrogate assembly during the test were in good agreement with the expected pulses. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would if it was dropped in the cask with the impact limiters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drop Testing of a Container for the Storage, Transport and Disposal of Intermediate Level Waste - 18078

Impact tests were performed, as part of a corresponding container's substantiation, during design development of a shielded container proposed for use at Sellafield for waste retrieval from the First Generation Magnox Storage Pond (FGMSP) in the UK. The mechanical test program comprised a 9 m free drop test onto an unyielding target in a container long lid edge down orientation at ambient conditions. Further, a 0,5 m free drop test onto a punch target was performed. Here, the container was orientated with the lid downwards in a way that the punch, a mild steel bar, impacts a filter lid. The test specimen was instrumented with strain gauges and accelerometers for the drop tests. Transient strains at selected points of the inner and outer container walls, at the shielding lid, as well as at the lid bolts were measured during the container's impact. Furthermore, decelerations of the container body, container lid, and the skip were measured. The complex geometrical changes of the container due to impact were determined by optical 3d- deformation measures using the projected fringes method in combination with multi-image photogrammetry. This paper summarizes the performance of the drop tests and various drop test results in context with the design development as well as aspects regarding the associated Finite Element (FE) analyses and post-test evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING↗

30 cm Drop Tests

The data from the multi-modal transportation test conducted in 2017 demonstrated that the inputs from the shock events during all transport modes (truck, rail, and ship) were amplified from the cask to the spent commercial nuclear fuel surrogate assemblies. These data do not support common assumption that the cask content experiences the same accelerations as the cask itself. This was one of the motivations for conducting 30 cm drop tests. The goal of the 30 cm drop test is to measure accelerations and strains on the surrogate spent nuclear fuel assembly and to determine whether the fuel rods can maintain their integrity inside a transportation cask when dropped from a height of 30 cm. The 30 cm drop is the remaining NRC normal conditions of transportation regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. Because the full-scale cask and impact limiters were not available (and their cost was prohibitive), it was proposed to achieve this goal by conducting three separate tests. This report describes the first two tests — the 30 cm drop test of the 1/3 scale cask (conducted in December 2018) and the 30 cm drop of the full-scale dummy assembly (conducted in June 2019). The dummy assembly represents the mass of a real spent nuclear fuel assembly. The third test (to be conducted in the spring of 2020) will be the 30 cm drop of the full-scale surrogate assembly. The surrogate assembly represents a real full-scale assembly in physical, material, and mechanical characteristics, as well as in mass.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for DOT 7A Type A Drum Closure and Drop Testing with Additional 49 CFR 173.465(c)(2) Testing and Analysis

The Savannah River National Laboratory (SRNL) is in the process of developing recommendation for the U S. Department of Energy contractors and vendors who want to qualify drums as U S. Department of Transportation (DOT) 7A Type A to meet 49 CFR 173.465 drop testing requirements for fissile and non-ftssile material to maintain containment. Based on the finite element analysis (FEA) models, the safety features suffering the maximum damage that result in loss of containment are identified as the closure ring mechanism (in entirety), the top (mouth area) of the drum, and the lid (including the gasket). The maximum damage is measured in terms of the collective ability of these combined three safety features to maintain containment. As such, both drop testing and FEA were performed to determine the sensitivities of these safety features to drop variations. As part of this effort, a series of physical drop tests and FEAs were conducted at SRNL. These tests used Skolnik drums, CQ5508L (see Attachment 1), which are open DOT 7A Type A open- head carbon steel 208-liter (55-gallon) drums with 12-gauge bolted closure rings. Variables studied were (1) stress relief methods during closure ring installation, (2) content configurations, and (3) drum orientations during a 4-foot free fall. It should be noted that the Skolnik CQ5508L drums have a closure ring with a "V shaped" cross section. (1) The closure testing with analysis confirmed that closure stress relief by rapping is necessary to distribute the closure ring tension around the perimeter and to maintain sufficient closure pre-load for lid retention during 4-foot drops of the heavier packages (500 to 1,000 lbs). It was concluded that no specific style of stress relief is preferred (e g., multi-step rapping/torqueing process, heavy hits vs. light hits, hitting near closure vs. away), as long as no additional change in bolt torque occurs with additional rapping. (2) (3) Modeling indicated that maximum damage is a result of both: (2) content configuration and (3) drop orientation. The worst-case content configuration is one with an eccentrically loaded concentrated content mass. FEA modeling showed that the center- of-gravity over top (CGoT) with the eccentric content on the high side was the orientation of maximum damage relative to drum lid retention. In this content configuration (i.e., CGoT), FEA modeling showed payloads over 500 lbs were required to contain a load distribution plate between content and lid. Both analysis and testing showed the drum with distribution plate can pass the 4-foot CGoT drop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations for Canister Design and Drop Testing

This paper discusses some considerations for the proposed design and analysis of canisters used to ship reactor debris from the Fukushima Daiichi nuclear plant. Energy-limited events, such as cask drops and other dynamic impacts, are evaluated much differently than other structures using static analysis. Static analysis of structures makes sense for engineers because static analysis is intuitive and material typically behaves in a linear elastic manner. Dynamic analyses are typically not intuitive because of non-linear material behavior. This is why canister designs need to be evaluated by dynamic finite element analysis and/or laboratory drop tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DROP TESTS RESULTS OF REVISED CLOSURE BOLT CONFIGURATION OF THE STANDARD WASTE BOX, STANDARD LARGE BOX 2, AND TEN DRUM OVERPACK PACKAGINGS

The Transuranic (TRU) Disposition Project at Savannah River Site will require numerous transfers of radioactive materials within the site boundaries for sorting and repackaging. The three DOT Type A shipping packagings planned for this work have numerous bolts for securing the lids to the body of the packagings. In an effort to reduce operator time to open and close the packages during onsite transfers, thus reducing personnel exposure and costs, an evaluation was performed to analyze the effects of reducing the number of bolts required to secure the lid to the packaging body. The evaluation showed the reduction to one-third of the original number of bolts had no effect on the packagings capability to sustain vibratory loads, shipping loads, internal pressure loads, and the loads resulting from a 4-ft drop. However, the loads caused by the 4-ft drop are difficult to estimate and the study recommended each of the packages be dropped to show the actual effects on the package closure. Even with reduced bolting, the packagings were still required to meet the 49 CFR 178.350 performance criteria for Type A packaging. This paper discusses the effects and results of the drop testing of the three packagings.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photos of Lansmont PDT 80 drop test machine at Los Alamos

The Los Alamos RP-SVS Radiation Protection Services group designed and constructed a drop tower facility for TA- 55 support work. The drop mechanism was supplied by the Lansmont company in Monterey CA. Los Alamos staffers Murray Moore and Yong Tao have noticed that the system is not dropping loads correctly, and they have photographed aspects of the PDT- 80 model system. The first 10 photos show the platen loaded with a cylindrical steel bar. The next 10 photos are of the roller-cam mechanism in the drop tower, and the last 2 photos indicate the amount of looseness in the platen when it is being pulled by a person.

47 OTHER INSTRUMENTATION↗

Introduction of the PELICAN loop, a Full-Scale Pressure Drop Test Facility

The Versatile Test Reactor (VTR) is a test reactor currently under development by the US Department of Energy. This reactor will rely on fast neutrons enabling novel and wide-ranging experiment to support the development of the various advanced reactor technologies. With the high flux achievable, accelerated testing of fluid and materials will be made possible. To support VTR design efforts [1], an experimental facility has been designed and constructed at Argonne National Laboratory to recreate the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, measures the pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. Here, we first describe the design considerations required to recreate aspects of the VTR. Then we discuss the design and construction of PELICAN to address these design requirements, the design and construction of the test articles placed inside PELICAN’s test section, and finally present some of the first experimental results.

Grannan, A. M.↗

A Compilation of Historical Data on Hagan Drop Testing with Results

The Hagan nuclear material storage container was designed in the late 1990’s to provide a robust container for daily use, safe transport within the plutonium facility PF-4, and storage of nuclear material for up to twenty years. There are currently >3000 loaded Hagan containers in use at TA-55. The majority of these are in the TA-55 vault, but they are also used in safes and in floor locations on the main floor of PF-4. The original design criteria are given below

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗