Search NASA⌕ Search

SEARCH · Search NASA

Results for “DS1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

AmeriFlux FLUXNET-1F US-DS1 Staten Corn 1

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-DS1 Staten Corn 1. This is the FLUXNET version of the carbon flux data for the site US-DS1 Staten Corn 1 produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located in a corn field in the California Delta on Staten Island. The tower is within several square kilometers of corn fields that comprise the vast majority of the southern and central portion of Staten Island

Christen, Nick [Hydrofocus, Inc]↗

AmeriFlux US-DS1 Staten Corn 1

This is the AmeriFlux version of the carbon flux data for the site US-DS1 Staten Corn 1. Site Description - This tower is located in a corn field in the California Delta on Staten Island. The tower is within several square kilometers of corn fields that comprise the vast majority of the southern and central portion of Staten Island

Christen, Nick↗

Measurement of the Mass and Width of the Ds1(2536)+ Meson

The decay width and mass of the D{sub s1}(2536){sup +} meson are measured via the decay channel D{sub s1}{sup +} {yields} D*{sup +} K{sub S}{sup 0} using 385 fb{sup -1} of data recorded with the BABAR detector in the vicinity of the {Upsilon}(4S) resonance at the PEP-II asymmetric-energy electron-positron collider. The result for the decay width is {Gamma}(D{sub s1}{sup +}) = 0.92 {+-} 0.03 (stat.) {+-} 0.04 (syst.)MeV. For the mass, a value of m(D{sub s1}{sup +}) = 2535.08 {+-} 0.01 (stat.) {+-} 0.15 (syst.)MeV/c{sup 2} is obtained. The mass difference between the D{sub s1}{sup +} and the D*{sup +} is measured to be m(D{sub s1}{sup +})-m(D*{sup +}) = 524.83 {+-} 0.01 (stat.) {+-} 0.04 (syst.)MeV/c{sup 2}, representing a significant improvement compared to the current world average. The unnatural spin-parity assignment for the D{sub s1}{sup +} meson is confirmed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of Biofilm Matrix-Associated Proteins from an Acid Mine Drainage Microbial Community

In microbial communities, extracellular polymeric substances (EPS), also called the extracellular matrix, provide the spatial organization and structural stability during biofilm development. One of the major components of EPS is protein, but it is not clear what specific functions these proteins contribute to the extracellular matrix or to microbial physiology. To investigate this in biofilms from an extremely acidic environment, we used shotgun proteomics analyses to identify proteins associated with EPS in biofilms at two developmental stages, designated DS1 and DS2. The proteome composition of the EPS was significantly different from that of the cell fraction, with more than 80% of the cellular proteins underrepresented or undetectable in EPS. In contrast, predicted periplasmic, outer membrane, and extracellular proteins were overrepresented by 3- to 7-fold in EPS. Also, EPS proteins were more basic by 2 pH units on average and about half the length. When categorized by predicted function, proteins involved in motility, defense, cell envelope, and unknown functions were enriched in EPS. Chaperones, such as histone-like DNA binding protein and cold shock protein, were overrepresented in EPS. Enzymes, such as protein peptidases, disulfide-isomerases, and those associated with cell wall and polysaccharide metabolism, were also detected. Two of these enzymes, identified as -N-acetylhexosaminidase and cellulase, were confirmed in the EPS fraction by enzymatic activity assays. Compared to the differences between EPS and cellular fractions, the relative differences in the EPS proteomes between DS1 and DS2 were smaller and consistent with expected physiological changes during biofilm development.

Jiao, Yongqin↗

Positron Emission Tomography/Computed Tomography Assessment After Immunochemotherapy and Irradiation Using the Lugano Classification Criteria in the IELSG-26 Study of Primary Mediastinal B-Cell Lymphoma

Purpose: To assess the predictive value of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for disease recurrence after immunochemotherapy (R-CHT) and mediastinal irradiation (RT), using the recently published criteria of the Lugano classification to predict outcomes for patients with primary mediastinal large B-cell lymphoma. Methods and Materials: Among 125 patients prospectively enrolled in the IELSG-26 study, 88 were eligible for central review of PET/CT scans after completion of RT. Responses were evaluated using the 5-point Deauville scale at the end of induction R-CHT and after consolidation RT. According to the Lugano classification, a complete metabolic response (CMR) was defined by a Deauville score (DS) ≤3. Results: The CMR (DS1, -2, or -3) rate increased from 74% (65 patients) after R-CHT to 89% (78 patients) after consolidation RT. Among the 10 patients (11%) with persistently positive scans, the residual uptake after RT was slightly higher than the liver uptake in 6 patients (DS4; 7%) and markedly higher in 4 patients (DS5; 4%): these patients had a significantly poorer 5-year progression-free survival and overall survival. At a median follow-up of 60 months (range, 35-107 months), no patients with a CMR after RT have relapsed. Among the 10 patients who did not reach a CMR, 3 of the 4 patients (positive predictive value, 75%) with DS5 after RT had subsequent disease progression (within the RT volume in all cases) and died. All patients with DS4 had good outcomes without recurrence. Conclusions: All the patients obtaining a CMR defined as DS ≤3 remained progression-free at 5 years, confirming the excellent negative predictive value of the Lugano classification criteria in primary mediastinal large B-cell lymphoma patients. The few patients with DS4 also had an excellent outcome, suggesting that they do not necessarily require additional therapy, because the residual {sup 18}F-fluorodeoxyglucose uptake may not reflect persistent lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of aluminum-stabilized superconducting cables for the Mu2e detector solenoid

Here, the Mu2e experiment at Fermilab is designed to measure the rare process of direct muon-to-electron conversion in the field of a nucleus. The experiment comprises a system of three superconducting solenoids, which focus secondary muons from the production target and transport them to an aluminum stopping target, while minimizing the associated background. The Detector Solenoid (DS) is the last magnet in the transport line and its main functions are to provide a graded field in the region of the stopping target as well as a precision magnetic field in a volume large enough to house the tracker downstream of the stopping target. The Detector Solenoid coils are designed to be wound using NbTi Rutherford cables conformed in high purity aluminum for stabilization and then cold-worked for strength. Two types of Al-stabilized conductor are required to build the DS coils, one for the gradient section and one for the spectrometer section of the solenoid. The dimensions are optimized to generate the required field profile when the same current is transported in both conductors. The conductors contain NbTi Rutherford cables with 12 (DS1) and 8 (DS2) strands respectively and are manufactured by two different vendors. This paper describes the results of the manufacturing of production lengths of the Al-stabilized cables needed to build the Mu2e Detector Solenoid as well as the testing campaigns and main results. The main cable properties and results of electrical and mechanical tests are summarized and discussed for each stage of the cable development process. Results are compared to design values to show how the production cables satisfy all the design criteria starting from the NbTi wires to the Al-stabilized cables.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Tool for Furthering GNSS Security Research: The Oak Ridge Spoofing and Interference Test Battery (OAKBAT)

A new global navigation satellite system (GNSS) dataset of digitized RF signals named Oak Ridge Spoofing and Interference Test Battery (OAKBAT) has been created. OAKBAT contains digitized spoofing signals that serve as both a supporting “sibling” and an advancement to the widely used Texas Spoofing Test Battery (TEXBAT) dataset [1]. OAKBAT at its core was developed to 1) allow for 100% reproducibility of the data, 2) provided more detailed metadata and contextual information about each dataset such as the precise moment that the spoofing and/or interference signals begins, positions used, constellations visible, etc., and 3) to provide datasets generated using the same key parameters as the TEXBAT ds1 through ds6 datasets. Through these “sibling” datasets it will now be possible to determine if the behavior of algorithms and designs developed using these datasets are being affected by possible intrinsic behavior and properties of the equipment used in the generation and digitization of the two datasets. The end goal of OAKBAT is to be a new resource for the community of researchers and developers working in the field of GNSS. This additional source of data provides a GNSS “playground” on which to experiment, explore, and evaluate new ideas.

Albright, Austin P.↗