Search NASA⌕ Search

SEARCH · Search NASA

Results for “DST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tre-DST: A Drug Susceptibility Test for Mycobacterium tuberculosis Using Solvatochromic Trehalose Probes

In 2024, an estimated 10 million people developed Tuberculosis (TB), nearly half a million of whom were infected with drug-resistant tuberculosis (DR-TB). Early detection of infection and drug resistance enables rapid engagement in effective care. Bacterial culture and nucleic acid testing remain the primary diagnostic methods, with smear microscopy being phased out. However, these methods present significant limitations for diagnosing drug resistance, such as lengthy time-to-result for phenotypic tests, as well as the need for prior knowledge of resistance mutations and prohibitive cost for molecular tests. To address this, we developed a rapid phenotypic TB drug susceptibility test, termed Tre-DST, based on novel metabolically incorporated trehalose probes, which specifically detect live mycobacteria. We used the nonpathogenic Mycobacterium smegmatis and the virulence-attenuated Mycobacterium tuberculosis (Mtb) H37Ra or auxotrophic Mtb to demonstrate a strong correlation between cost-effective plate reader results and flow cytometry data, suggesting that the plate reader is a suitable fluorescence detector for Tre-DST. We determined that adding a 1-week incubation step allowed Mtb samples originally seeded at 10 4 CFU/mL to become detectable, over 2 weeks earlier than colony-forming unit analysis. We found that Tre-DST reports on drug susceptibility in a drug-agnostic manner, demonstrating loss of fluorescence with frontline TB drugs as well as the newer drug bedaquiline. Tre-DST distinguished RIF- and INH-resistant auxotrophs from susceptible controls and accurately reported the resistance activity. Ultimately, because Tre-DST is agnostic to mechanisms of drug resistance, this assay is likely compatible with all WHO-recommended and future DR-TB drugs as a diagnostic in reference laboratories.

diagnostics↗

Open World Dempster-Shafer Theory/The Transferable Belief Model with Intervals: A Practitioner's Guide to DST and TBM

Dempster-Shafer theory (DST) is a mathematical framework that allows for uncertainty or ignorance to be quantified and included when making predictions from evidence. This is in contrast to Bayesian theory, which does not allow for any quantification of ignorance. The framework is described in great detail in [7]. DST is particularly useful for problems where the inclusion of additional evidence (for example, data from another sensor) could lead to a different conclusion. Thus, it is a useful data fusion method, especially in applications not suited to maximum likelihood or maximum a posteriori estimations due to limited samples or incomplete prior knowledge.

97 MATHEMATICS AND COMPUTING↗

The latitudinal variation of geoelectromagnetic disturbances during large ( Dst ≤ ₋100 nT) geomagnetic storms

Geoelectromagnetic disturbances (GMDs) are an important consequence of space weather that can directly impact many types of terrestrial infrastructure. In this paper, we analyze 30 years of SuperMAG magnetometer data from the range of magnetic latitudes 20°≤λ≤75° to derive characteristic latitudinal profiles for median GMD amplitudes. Based on this data, we obtain a parameterization of these latitudinal profiles of different types of GMDs, providing an analytical fit with Dst-dependent parameters. Finally, we also obtain probabilistic estimates for the magnitudes of “100 year” GMDs, finding that $\dot{_B}$ = 6.9 (3.60–12.9) nT/s should be expected at 45°≤λ< 50°, exceeding the 5 nT/s threshold for dangerous inductive heating.

58 GEOSCIENCES↗

NDE Technology Development Program for Hanford DST Non-Visual Volumetric Inspection Technology – Phase II; Technical Letter Report on Air-slot NDE Sensor Maturation Testing

The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Phase II Flaw Detection Performance Tests in August 2018 that allowed the newly matured ultrasonic guided wave phased-array (GWPA) air-slot NDE sensor—“Hanford-Probe A”—developed by Guidedwave to be evaluated for its flaw detection capability and repeatability. A portion of the Phase II Flaw Detection Performance Tests was performed on a subset of test flaws on which the original GWPA sensor was evaluated during Phase I Sensor Effectiveness Testing (SET) to facilitate a comparison in flaw detection performance between Hanford-Probe A and the original GWPA sensor demonstrated in Phase I. The objective of the performance comparison was to determine the extent to which GWPA sensor design changes impacted the flaw detection performance upon which selection of the sensor technology was originally based for the purpose of determining whether the flaw detection performance of the newly matured Hanford-Probe A GWPA air-slot NDE sensor is at least equal to that of the original GWPA sensor evaluated under Phase I SET. This technical letter report presents the results produced by the new Hanford-Probe A on the Phase I test flaws and the results of the flaw detection performance comparison between Hanford-Probe A and the original GWPA sensor demonstrated in Phase I.

47 OTHER INSTRUMENTATION↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Spill in Downstream Transport due to Injector Faults [PowerPoint]

We have investigated injector faults with numerical experiments. For this investigation we used the nominal tune that is also being used to assess beam stability. Beam spill in the DST due to a serious injector fault was evaluated using the LSP slice algorithm. Only the most serious fault investigated (-350 keV) caused beam spill in the DST. DST transport focusing solenoids limit the beam spill. Beam spill in the DST is the result of large halo caused by betatron oscillations of the mismatched beam. Bremsstrahlung radiation from the DST beam spill was estimated from Tom Martin scaling normalized to DARHT-I. In conclusion, Scorpius is reasonably safe from beam spill radiation in the DST due to injector faults.

43 PARTICLE ACCELERATORS↗

Hanford Single-Shell Tank and Double-Shell Tank Integrity Programs - 16390

Waste at Hanford is stored in 149 single-shell tanks and 28 double-shell tanks. Concerns related to aging radioactive waste storage facilities throughout the DOE complex led to Brookhaven National Laboratory (BNL) developing guidelines for structural integrity programs for tank systems. The committee of experts who developed these guidelines is commonly known as the Tank Structural Integrity Panel (TSIP). The DOE has subsequently adopted these guidelines, and requires site operators to have a program consistent with them. The Double-Shell Tank (DST) integrity is maintained with a variety of activities such as ultrasonic and visual inspections, chemistry controls, corrosion monitoring and structural analyses methods. In October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of 241-AY-102 was leaking. WRPS contracted a panel of experts from industry and academia to provide advice and recommendations for the DST Integrity Program. The panel focused on three concerns: - No Early warning - Determine why the existing DST Integrity Program did not predict a primary tank failure or provide early warning of the pending failure. - Program improvements - Recommend activities to either predict a primary tank failure or increase the probability of early warning. - Forensic recommendations - The panel provided additional recommendations regarding forensic assessment of Tank 241-AY-102 (AY-102) to facilitate a conclusion on why the leak occurred. WRPS has prepared a response to the concerns of the panel coupled with recommendations for project action to strengthen the DST Integrity Program [4]. The purpose of this DST Integrity Improvement Plan is to translate the recommendations to specific project activities that are technically and practically responsive. To improve the understanding of the Single-Shell Tank (SST) integrity, WRPS, the Department of Energy-Office of River Protection tank operations contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matter experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase, which was completed in 2015, was focused on efforts to envelope the integrity of the tanks. It was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary, based on the outcome from the initial work, a second phase would be focused on further definition of the integrity of the tanks and liners. The two combined phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by an Independent Qualified Registered Professional Engineer. This paper will summarize the current status of the DST and SST Integrity Programs and discuss the ongoing efforts to improve these programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electron Dropout Events and Flux Enhancements Associated With Geomagnetic Storms Observed by PROBA-V/Energetic Particle Telescope From 2013 to 2019

Electron flux variations for E > 500 keV during geomagnetic storms are investigated using the Energetic Particle Telescope (EPT). This detector launched in May 2013 on board the satellite PROBA-V at an altitude of 820 km was designed to provide uncontaminated spectra of electrons, protons, and alpha particles. Electron flux dropout events are observed during the main phase of each storm and even during substorms: a rapid reduction of the electron flux is noted throughout the outer electron radiation belt at all energies above about 0.5 MeV on timescales of a few hours. The electron spectrograms measured by the EPT between 2013 and 2019 show that after each geomagnetic storm, dropout events are followed by a flux enhancement starting first at low L values, and reaching the slot or even the inner belt for the strongest storms. We determine the link between Disturbed Storm Time (Dst) and the minimum value of the L-shell where the dropouts deplete the outer belt, as well as the nonlinear relation between Dst and the minimum L-shell where the flux penetrates in the slot region or even the inner belt during the storms. Dropouts appear at all energies measured by EPT and penetrate down to $\textit{L}$~3.5 for the strongest events. Dropouts are observed at Low Earth Orbit each time Dst has an inverted peak < –40 nT. Flux enhancements appear at lower L only for big storm events with Dst < –50 nT. They penetrate down to an impenetrable barrier with a minimum L-shell related to Dst and to the energy. For E > 1 MeV, this limit is also linked to the plasmapause position.

58 GEOSCIENCES↗

GMD Coupling to Power Systems and Disturbance Mitigation

Presentation includes slides on Geomagnetic Disturbance: Ground Fields; Geomagnetic Disturbance: Coupling to Bulk Electric System; Geomagnetic Disturbance: Transformers; GMD Assessment Workflow (TPL-007-1); FERC order 830; Goals; SuperMag (1 min data) Nov. 20-21, 2003 Storm (DST = -422); Spherical Harmonics; Spherical Harmonics Nov. 20-21, 2003 Storm (DST = -422); DST vs HN0,0; Fluctuations vs. DST; Fluctuations; Conclusions and Next Steps; GMD Assessment Workflow (TPL-007-1); EMP E3 Coupling to Texas 2000 Bus Model; E3 Coupling Comparison (total GIC) Varying Ground Zero; E3 Coupling Comparison (total MVAR) Varying Ground Zero; E3 Coupling Comparison (GIC) at Peak Ground Zero; E3 Coupling Comparison (GIC) at Peak Ground Zero; and Conclusion.

58 GEOSCIENCES↗

Chemistry Envelope for Pitting and Stress Corrosion Cracking Mitigation

The present waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980s in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits were coupled with corrosion testing results from Pacific Northwest Laboratory (PNL) and adopted for corrosion control of the DST waste at the Hanford Site. Since that time, the temperatures of many DST wastes have decreased to less than 50 °C as the radioactive material has decayed, the testing program in Argentina demonstrated that chloride ion in Hanford Site waste could cause pitting, and other work showed that dilute solutions could cause pitting at the liquid air interface (LAI). Moreover, future transfers from the single shell tanks and the waste treatment plant and process changes may shift the DST waste chemistries to a broader range of compositions with higher aggressive anion concentrations than the wastes that are presently stored. The decreasing temperatures led to the formulation of new chemistry controls for the minimization of SCC risks for operations below 50 °C in 2010, and these controls were partially adopted. The Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG) recommended that additional testing be performed to assess the potential for pitting and LAI corrosion. Since 2015, DNV-GL, SRNL, and the Hanford Site laboratory have investigated pitting and LAI corrosion at current and anticipated DST chemistries and Savannah River National Laboratory (SRNL) undertook a statistically based investigation of the role of nitrate and halide ion induced pitting corrosion. The objective was to develop a comprehensive waste chemistry envelope for the simultaneous minimization of the pitting and SCC risks caused by halide and nitrate ions. This report summarizes the technical basis for the new waste chemistry envelope to minimize the potential for both pitting and cracking corrosion induced by nitrate and halide ions, and the strategies used for the validation of the new controls.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deep Sludge Gas Release Event Analytical Evaluation

Long Abstract. Full Text. The purpose of the Deep Sludge Gas Release Event Analytical Evaluation (DSGRE-AE) is to evaluate the postulated hypothesis that a hydrogen GRE may occur in Hanford tanks containing waste sludges at levels greater than previously experienced. There is a need to understand gas retention and release hazards in sludge beds which are 200 -300 inches deep. These sludge beds are deeper than historical Hanford sludge waste beds, and are created when waste is retrieved from older single-shell tanks (SST) and transferred to newer double-shell tanks (DST).Retrieval of waste from SSTs reduces the risk to the environment from leakage or potential leakage of waste into the ground from these tanks. However, the possibility of an energetic event (flammable gas accident) in the retrieval receiver DST is worse than slow leakage. Lines of inquiry, therefore, are (1) can sludge waste be stored safely in deep beds; (2) can gas release events (GRE) be prevented by periodically degassing the sludge (e.g., mixer pump); or (3) does the retrieval strategy need to be altered to limit sludge bed height by retrieving into additional DSTs? The scope of this effort is to provide expert advice on whether or not to move forward with the generation of deep beds of sludge through retrieval of C-Farm tanks. Evaluation of possible mitigation methods (e.g., using mixer pumps to release gas, retrieving into an additional DST) are being evaluated by a second team and are not discussed in this report. While available data and engineering judgment indicate that increased gas retention (retained gas fraction) in DST sludge at depths resulting from the completion of SST 241-C Tank Farm retrievals is not expected and, even if gas releases were to occur, they would be small and local, a positive USQ was declared (Occurrence Report EM-RP--WRPS-TANKFARM-2012-0014, "Potential Exists for a Large Spontaneous Gas Release Event in Deep Settled Waste Sludge"). The purpose of this technical report is to (1) present and discuss current understandings of gas retention and release mechanisms for deep sludge in U.S. Department of Energy (DOE) complex waste storage tanks; and (2) to identify viable methods/criteria for demonstrating safety relative to deep sludge gas release events (DSGRE) in the near term to support the Hanford C-Farm retrieval mission. A secondary purpose is to identify viable methods/criteria for demonstrating safety relative to DSGREs in the longer term to support the mission to retrieve waste from the Hanford Tank Farms and deliver it to the Waste Treatment and Immobilization Plant (WTP). The potential DSGRE issue resulted in the declaration of a positive Unreviewed Safety Question (USQ). C-Farm retrievals are currently proceeding under a Justification for Continued Operation (JCO) that only allows tanks 241-AN-101 and 241-AN-106 sludge levels of 192 inches and 195 inches, respectively. C-Farm retrievals need deeper sludge levels (approximately 310 inches in 241-AN-101 and approximately 250 inches in 241-AN-106). This effort is to provide analytical data and justification to continue retrievals in a safe and efficient manner.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Van Allen Probes observation and modeling of chorus excitation and propagation during weak geomagnetic activities

We report correlated data on nightside chorus waves and energetic electrons during two small storm periods: 1 November 2012 (Dst ≈ –45) and 14 January 2013 (Dst ≈ –18). The Van Allen Probes simultaneously observed strong chorus waves at locations L = 5.8 – 6.3, with a lower frequency band 0.1–0.5fce and a peak spectral density ~10 –4 nT 2 /Hz. In the same period, the fluxes and anisotropy of energetic (~10–300 keV) electrons were greatly enhanced in the interval of large negative interplanetary magnetic field Bz. Using a bi-Maxwellian distribution to model the observed electron distribution, we perform ray tracing simulations to show that nightside chorus waves are indeed produced by the observed electron distribution with a peak growth for a field-aligned propagation approximately between 0.3f ce and 0.4f ce , at latitude <7°. Moreover, chorus waves launched with initial normal angles either θ < 90° or > 90° propagate along the field either northward or southward and then bounce back either away from Earth for a lower frequency or toward Earth for higher frequencies. The current results indicate that nightside chorus waves can be excited even during weak geomagnetic activities in cases of continuous injection associated with negative Bz. Furthermore, we examine a dayside event during a small storm C on 8 May 2014 (Dst ≈ –45) and find that the observed anisotropic energetic electron distributions potentially contribute to the generation of dayside chorus waves, but this requires more thorough studies in the future.

58 GEOSCIENCES↗

Prediction of MeV electron fluxes throughout the outer radiation belt using multivariate autoregressive models

The Van Allen radiation belts surrounding the Earth are filled with MeV-energy electrons. This region poses ionizing radiation risks for spacecraft that operate within it, including those in geostationary orbit (GEO) and medium Earth orbit. In order to provide alerts of electron flux enhancements, 16 prediction models of the electron log-flux variation throughout the equatorial outer radiation belt as a function of the McIlwain L parameter were developed using the multivariate autoregressive model and Kalman filter. Measurements of omnidirectional 2.3 MeV electron flux from the Van Allen Probes mission as well as >2 MeV electrons from the GOES 15 spacecraft were used as the predictors. Furthermore, we selected model explanatory parameters from solar wind parameters, the electron log-flux at GEO, and geomagnetic indices. For the innermost region of the outer radiation belt, the electron flux is best predicted by using the Dst index as the sole input parameter. For the central to outermost regions, at L≥4.8 and L ≥5.6, the electron flux is predicted most accurately by including also the solar wind velocity and then the dynamic pressure, respectively. The Dst index is the best overall single parameter for predicting at 3 ≤ L ≤ 6, while for the GEO flux prediction, the K P index is better than Dst. Finally, a test calculation demonstrates that the model successfully predicts the timing and location of the flux maximum as much as 2 days in advance and that the electron flux decreases faster with time at higher L values, both model features consistent with the actually observed behavior.

58 GEOSCIENCES↗

Direct state tomography using continuous variable measuring device

Compared with the conventional quantum state tomography (QST), the efficiency of the direct state tomography (DST) using weak value is very low. However, DST is easily manipulated in experiments. We modify the direct state tomography by using coupling-deformed observables. The modified direct state measurement is valid for arbitrarily large measurement strength. The optimal measurement strengths are obtained to attain the highest efficiency. The efficiency of DST is significantly improved in the modified strategy, and the reconstructed state has no inherent bias. The state reconstruction strategy investigated in this paper might be useful in actual experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A constitutive model for sheared dense suspensions of rough particles

In a concentrated suspension, particles come into contact due to the presence of asperities on their surfaces. As a result, the contact forces and interparticle friction become one of the important factors governing the rheology of rigid particle suspensions at high concentrations. We show that a load-dependent friction model can be used to reproduce the experimentally observed shear thickening [ST—continuous and discontinuous (DST)] behavior with an increase in the asperity size. Increasing the particle surface roughness size leads to a decrease in the critical shear rate above which shear-thickening takes place, a reduction in the critical volume fraction for DST and an increase in the viscosity jump across non-shear-thickened to shear-thickened regime. In this paper, we propose a constitutive model to quantify the effect of increasing the roughness size on the rheology of dense ST suspensions as well as on the critical shear rate for ST and the critical volume fraction for DST. We fit this model to our simulation data for stress controlled shear flow of dense rough particle suspensions. Once the fitting is complete, these equations are used to predict exact volume fractions and shear stress values for transitions between three regimes on the shear stress-shear rate flow state diagram for different roughness values. Furthermore, the results of this study can be used to tune the particle surface roughness for manipulating the dense suspension rheology according to different applications.

42 ENGINEERING↗