Search NASA⌕ Search

SEARCH · Search NASA

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Parametric evaluation of ducted fuel injection in an optically accessible mixing-controlled compression-ignition engine with two- and four-duct assemblies

Ducted fuel injection (DFI) is a strategy to improve fuel/charge-gas mixing in direct-injection compression-ignition engines. DFI involves injecting fuel along the axis of a small tube in the combustion chamber, which promotes the formation of locally leaner mixtures in the autoignition zone relative to conventional diesel combustion. Previous work has demonstrated that DFI is effective at curtailing engine-out soot emissions across a wide range of operating conditions. This study extends previous investigations, presenting engine-out emissions and efficiency trends between ducted two-orifice and ducted four-orifice injector tip configurations. For each configuration, parameters investigated include injection pressure, injection duration, intake manifold pressure, intake manifold temperature, start of combustion timing, and intake-oxygen mole fraction. For both configurations and across all parameters, DFI reduced engine-out soot emissions compared to conventional diesel combustion, with little effect on other emissions and engine efficiency. Emissions trends for both configurations were qualitatively the same across the parameters investigated. The four-duct configuration had higher thermal efficiency and indicated-specific engine-out nitrogen oxide emissions but lower indicated-specific engine-out hydrocarbon and carbon monoxide emissions than the two-duct assembly. Both configurations achieved indicated-specific engine-out emissions for both soot and nitrogen oxides that comply with current on- and off-road heavy-duty regulations in the United States without exhaust-gas aftertreatment at an intake-oxygen mole fraction of 12%. High-speed in-cylinder imaging of natural soot luminosity shows that some conditions include a second soot-production phase late in the cycle. The probability of these late-cycle events is sensitive to both the number of ducted sprays and the operating conditions.

Yraguen, Boni Frances↗

Levelized cost of energy for a Backward Bent Duct Buoy

The Reference Model Project, supported by the U.S. Department of Energy, was developed to provide publically available technical and economic benchmarks for a variety of marine energy converters. The methodology to achieve these benchmarks is to develop public domain designs that incorporate power performance estimates, structural models, anchor and mooring designs, power conversion chain designs, and estimates of the operations and maintenance, installation, and environmental permitting required. The reference model designs are intended to be conservative, robust, and experimentally verified. The Backward Bent Duct Buoy (BBDB) presented in this paper is one of three wave energy conversion devices studied within the Reference Model Project. Comprehensive modeling of the BBDB in a Northern California climate has enabled a full levelized cost of energy (LCOE) analysis to be completed on this device.

marine hydrokinetic energy development↗

Propagation and radiation of sound from flanged circular ducts with circumferentially varying wall admittances. I Semi-infinite ducts. II - Finite ducts with sources

Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.

Fuller, C. R.↗

Using Ducted Fuel Injection to Attenuate Soot Formation in a Mixing-Controlled Compression Ignition Engine

Ducted fuel injection (DFI) has been introduced as a strategy to enhance the fuel/charge gas mixing within the combustion chamber of a direct-injection mixing-controlled compression ignition engine. The concept involves injecting each fuel spray through a small tube within the combustion chamber to facilitate the creation of a leaner mixture in the autoignition zone, relative to a conventional free-spray configuration (i.e., a fuel spray that is not surrounded by a duct). While previous experiments demonstrated that DFI lowers both soot incandescence and soot mass in a constant-volume combustion vessel with a single-component normal-alkane fuel (n-dodecane), here we provide the first evidence that the technology provides similar benefits in an engine application using a commercial diesel fuel containing ~30 wt% aromatics. The present study investigates the effects on engine-out emissions and efficiency with a two-orifice injector tip for charge gas mixtures containing 16 and 21 mol% oxygen. The result is that DFI is confirmed to be effective at curtailing engine-out soot emissions. It also breaks the tradeoff between emissions of soot and nitrogen oxides (NOx) by simultaneously attenuating soot and NO x with increasing dilution.

33 ADVANCED PROPULSION SYSTEMS↗

To Duct or Not to Duct: Evaluating the Space Conditioning Impacts of Heat Pump Water Heaters in the PNNL Lab Homes

Heat pump water heaters (HPWH) are a promising technology for substantially reducing water heating-related energy use in the residential sector. However, concerns have been raised regarding the impact of HPWHs on space conditioning energy when installed in conditioned space, primarily in northern climates. For example, the Northwest Energy Efficiency Alliance (NEEA’s) Northern Climate HPWH Specification, which describes the characteristics a HPWH must have to be incentivized in cold climates in the Pacific Northwest (PNW), requires exhaust ducting for their Tier II-specified products and both supply and exhaust ducting for the Tier III-specified product (NEEA 2013). However, these concerns and installation recommendations are based on modeling and comparative field data are not available to verify modeled performance. This study examines the overall performance and operation of two GE GeoSpring HPWHs in conditioned space in the matched pair of PNNL Lab Homes with no ducting, exhaust ducting, and full ducting (supply and exhaust) and explores the interactions between the HPWH and the home’s heating/cooling system. The data collected in this field evaluation suggest that previous modeling may not completely characterize the complex interactions of HPWHs, HVAC systems, and ducting. This report discusses the impact on space conditioning and water heater energy use of configuring an HPWH with exhaust only ducting or full ducting, as compared to an unducted HPWH. Additional cost analysis is necessary to assess the cost effectiveness of ducting and to make formal recommendations regarding appropriate installation of HPWHs in more varied scenarios.

energy efficiency↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

Determining tolerance requirements for spray-duct alignment in ducted fuel injection

Several ducted fuel injection (DFI) studies have highlighted the importance of accuracy in aligning the duct axis with that of its corresponding spray for optimal effectiveness, as misalignment adversely impacts the method’s performance. The need for accurate alignment could lead to added manufacturing complexity via tighter tolerances. This study systematically explores cases of horizontal, vertical, and rotational misalignment, analyzing their respective effects on DFI performance. Vertical and horizontal misalignments at the duct inlet plane were varied at magnitudes of 6.25%, 12.5%, and 25.0% of the duct diameter, corresponding to 0.125, 0.25, and 0.5 mm, respectively. Rotational misalignments were set at 1°, 2°, and 4°, corresponding to 3.65%, 7.30%, and 14.6%, respectively, of the duct diameter at its inlet plane. The investigation yields spray-duct alignment tolerance limits and highlights the influence of misalignment direction on emissions due to the interactions with swirl and squish inside the combustion chamber. The results indicate that the tolerance limits for the alignment are within 4° and 0.5 mm relative to the geometrically aligned position. If the misalignment exceeds 4°of rotation or 0.5 mm in the horizontal direction, the beneficial effects on soot reduction using this method are no longer observed. The findings contribute to an understanding that can be used to optimize DFI for cleaner and more efficient combustion in compression-ignition engines.

Şener, Ramazan↗

Developing flow in S-shaped ducts. 2: Circular cross-section duct

Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

Taylor, A. M. K. P.↗

Ducted combustion systems utilizing duct-exit tabs

A ducted combustion system is disclosed. The ducted combustion system includes a combustion chamber bound by a flame deck surface of a cylinder head of an internal combustion engine and by a piston top surface of a piston disposed within the internal combustion engine. The system includes a fuel injector including one or more orifices, the one or more orifices injecting fuel into the combustion chamber as at least one fuel jet. The system includes at least one duct disposed within the combustion chamber between the flame deck surface and the piston top surface, the at least one duct including one or more structural tabs proximate to an outlet of the at least one duct and being disposed such that the at least one fuel jet, at least partially, enters one of the at least one duct upon being injected into the combustion chamber.

42 ENGINEERING↗

Developing flow in S-shaped ducts. 1: Square cross-section duct

Laser-Doppler velocimetry was used to measure the laminar and turbulent flow in an S-duct formed with two 22.5 deg sectors of a bend with ratio of mean radius of curvature to hydraulic diameter of 7.0. The boundary layers at the inlet to the bend were about 25% and 15% of the hydraulic diameter for the laminar and turbulent flows, respectively. Pressure-driven secondary flows develop in the first half of the S-duct and persist into the second half but are largely reversed by the exit plane as a consequence of the change in the sense of curvature. There is, however, a region near the outer wall of the second bend where the redistribution of the streamwise isotachs results in a reinforcement of the secondary flow which was established in the first half of the S-duct. The net redistribution of the streamwise isotachs is comparable to that occurring in unidirectional bends of stronger curvature. The wall pressure distribution was also measured for the turbulent flow and quantifies the expected large variations in the longitudinal pressure gradient distributions which occur at different radial locations.

Taylor, A. M. K. P.↗