Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dark field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

Forecasting the Decay of Hybrid Perovskite Performance Using Optical Transmittance or Reflected Dark-Field Imaging

The practicality and economic viability of hybrid perovskite solar cells hinge on their operational lifetime, and methods for forecasting the performance of perovskites under different operational stresses are urgently needed. Here, we explore the evolution of material-level optoelectronic properties as MAPbI 3 degrades and discover universal behaviors where the carrier diffusion length (L D ) decays before quasi-Fermi-level splitting (ΔE F ), regardless of the specific stress protocol (oxygen, humidity, thermal stress, or a combination). We employ a machine learning greedy feature selection model that uses initially measured properties to predict the time it takes L D to decrease to 85% of its initial value with a prediction accuracy of 12.8%. This model reveals a strong correlation between the initial rate of transmittance change and the time until loss of transport. We translate this material-level finding to photovoltaic device-level forecasting by demonstrating that the rate of change of transmittance is equivalent to the rate of change of the spatial standard deviation of dark-field image intensity (i.e., scattered light intensity) collected in reflection mode (and thus applicable to devices with opaque contacts). Furthermore, this work demonstrates that transmittance and scattering methods are highly effective for accelerated material (and device) stability evaluation and forecasting.

14 SOLAR ENERGY↗

High-speed quantitative X-ray multi-contrast imaging with deep learning based modulated pattern analysis

The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.

X-ray at-wavelength metrology↗

Investigating Grain Structure and Microcracking in SiCf-SiCm Composites Using 4D-STEM

Silicon carbide (SiC) fiber-reinforced SiC matrix composites (SiCf-SiCm) are promising materials for accident-tolerant fuel (ATF) cladding in light water reactors. This paper, using four-dimensional scanning transmission electron microscopy (4D-STEM), studied the microstructure of SiCf-SiCm at nanoscale and provided grain statistics at the CVI/fiber region. Here, the results reveal that CVI region mainly contain irregular sub-micron grains (115 nm to 1800 nm) with a preferred orientation, while the fiber region has nano equiaxed grains (21 nm to 78 nm) with random orientations. Centered dark field imaging over the fiber regions verified the grain size measurement by 4D-STEM. Through 4D-STEM virtual dark field imaging and orientation mapping, intragranular propagation was identified as the fracture mechanism for a microcrack observed within the CVI region. The amorphous pyrolytic carbon layer was also shown to effectively arrest the microcrack.

4D-STEM↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

Imaging surface topography with coherent x-ray reflectivity: Theory, kinematics, and simulations

A theoretical formalism is described for understanding coherent x-ray reflectivity (CXR) from the surface of a semi-infinite crystal having a variable surface topography, described by the height profile ℎ(𝑥,𝑦). The surface topography is imaged as a complex “effective density,” obtained from the phasing and inversion of the coherent x-ray reflectivity data, measured through a rocking scan centered at a vertical momentum transfer 𝑄$^{0}_{𝑧}$ and a vertical range Δ⁢𝑄 𝑧 . The formalism predicts that the effective density has an amplitude with a maximum located at the surface height for each position within the surface plane. The phase of the effective density has a lateral variation that is controlled by the surface height and a vertical variation that reflects a combination of the interfacial structure and specific choice of measurement conditions. This understanding enables direct observation of nanometer-scale interfacial topography, i.e., ℎ⁡(𝑥,𝑦)⁢𝑐 𝑠 (where 𝑐 𝑠 is the vertical substrate lattice parameter) with Å-scale sensitivity to surface height. Numerical simulations illustrate and confirm the theoretical results. These results show how the interpretation of the interfacial density phase obtained by CXR data inversion (i.e., surface topography with respect to a flat surface) is conceptually similar to that previously known for Bragg coherent diffraction imaging (BCDI) measurements of isolated nanoparticles (i.e., lattice displacements with respect to an ideal crystal lattice). This suggests that CXR can be thought of as a form of dark field imaging with respect to the bright field BCDI approach. An implication of these results is that interfacial imaging may bypass some of the significant challenges associated with BCDI imaging of multiple particles having different orientations.

X-ray imaging↗

Five-second STEM dislocation tomography for 300 nm thick specimen assisted by deep-learning-based noise filtering

Scanning transmission electron microscopy (STEM) is suitable for visualizing the inside of a relatively thick specimen than the conventional transmission electron microscopy, whose resolution is limited by the chromatic aberration of image forming lenses, and thus, the STEM mode has been employed frequently for computed electron tomography based three-dimensional (3D) structural characterization and combined with analytical methods such as annular dark field imaging or spectroscopies. However, the image quality of STEM is severely suffered by noise or artifacts especially when rapid imaging, in the order of millisecond per frame or faster, is pursued. Here we demonstrate a deep-learning-assisted rapid STEM tomography, which visualizes 3D dislocation arrangement only within five-second acquisition of all the tilt-series images even in a 300 nm thick steel specimen. The developed method offers a new platform for various in situ or operando 3D microanalyses in which dealing with relatively thick specimens or covering media like liquid cells are required.

47 OTHER INSTRUMENTATION↗