Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data-driven dynamic reduced models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data Driven Model Development for the Supersonic Semispan Transport (S(sup 4)T)

We investigate two common approaches to model development for robust control synthesis in the aerospace community; namely, reduced order aeroservoelastic modelling based on structural finite-element and computational fluid dynamics based aerodynamic models and a data-driven system identification procedure. It is shown via analysis of experimental Super- Sonic SemiSpan Transport (S4T) wind-tunnel data using a system identification approach it is possible to estimate a model at a fixed Mach, which is parsimonious and robust across varying dynamic pressures.

Kukreja, Sunil L.↗

Data Driven Model Development for the SuperSonic SemiSpan Transport (S(sup 4)T)

In this report, we will investigate two common approaches to model development for robust control synthesis in the aerospace community; namely, reduced order aeroservoelastic modelling based on structural finite-element and computational fluid dynamics based aerodynamic models, and a data-driven system identification procedure. It is shown via analysis of experimental SuperSonic SemiSpan Transport (S4T) wind-tunnel data that by using a system identification approach it is possible to estimate a model at a fixed Mach, which is parsimonious and robust across varying dynamic pressures.

Kukreja, Sunil L.↗

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

Hybrid data-driven and model-informed online tool wear detection in milling machines

Precision machining tool wear is responsible for low product throughput and quality. Monitoring the tool wear online is vital to prevent degradation in machining quality. However, direct real-time tool wear measurement is not practical. This paper presents residual-based anomaly detection models, combining a hybrid model comprised of a physics-based model and a data-driven model (a decision tree or a neural network) to predict signals of interest (e.g., power or forces) under nominal conditions, followed by Page’s cumulative sum test for detecting tool wear on-line using the computer numerical control machine measurements. The most informative features are ranked using dynamic programming and its approximation variants from real-time measurements and machine settings, such as the width of cut, depth of cut, feed rate and spindle speed, that serve as inputs to the predictive models. The baseline nominal model is incrementally updated with experimental data via a gradient boosted adaptation model to generate the residuals that account for discrepancies between the actual machine data under normal conditions and the baseline nominal model predictions. The hybrid model is validated against 20 Mazak milling machine experimental tests and one Haas run-to-failure experiment. The proposed anomaly detector is applied to synthetic data from simulations of the physics-based model at different operating conditions, measurement noise levels, and tool wear levels, and the methods were able to achieve an overall 92% accuracy in data with 1% noise. The anomaly detection methods based on hybrid model reduced the false alarms of either the data-driven or physical-based models alone, and are found to be capable of good online detection of tool wear.

Online anomaly detection↗

Vector-Ordering Filter Procedure for Data Reduction

The vector-ordering filter (VOF) technique involves a procedure for sampling a large population of data vectors to select a subset of data vectors that fully characterize the state space of the large population. The VOF technique enables a large reduction of the volume of data that must be handled in the automated monitoring system and method discussed in the two immediately preceding articles. In so doing, the VOF technique enables the development of data-driven mathematical models of a monitored asset from sets of data that would otherwise exceed the memory capacities of conventional engineering computers. Data-driven mathematical models have been shown to offer high fidelity for purposes of control and monitoring of assets. In practice, a collection of asset-operating observations is acquired with the intention that the collection contain observations characteristic of the full dynamic range of operation of the asset. Often, such a collection contains an extremely large number of observations, many of which are redundant. The VOF technique fills the need for a means to extract, from the original collection of observational data, a reduced data matrix that excludes redundant data while maintaining the full statistical character and dynamic range of the original data. The reduced data matrix can then be used as the input data for development of a mathematical model of the monitored asset, or as training data for a neural-network substitute for an explicit mathematical model of the asset. Alternatively, the reduced data matrix can, itself, be used directly as a mathematical model of the monitored asset, as is commonly done in multivariate state-estimation techniques. The original data are collected from the asset over a range of operating states and are put in matrix form. Each column vector in the original data matrix represents the signal values acquired at a particular operational state of the asset. Thus, the number of columns of the original data matrix equals the number of observed states and the number of rows in this matrix equals the number of signals acquired at each observation. In the VOF technique, one extracts the reduced data matrix from the original data matrix through the selection of a representative subset of the column (state) vectors.

Bickford, Randall L.↗

Particle Filtering for Model-Based Anomaly Detection in Sensor Networks

A novel technique has been developed for anomaly detection of rocket engine test stand (RETS) data. The objective was to develop a system that postprocesses a csv file containing the sensor readings and activities (time-series) from a rocket engine test, and detects any anomalies that might have occurred during the test. The output consists of the names of the sensors that show anomalous behavior, and the start and end time of each anomaly. In order to reduce the involvement of domain experts significantly, several data-driven approaches have been proposed where models are automatically acquired from the data, thus bypassing the cost and effort of building system models. Many supervised learning methods can efficiently learn operational and fault models, given large amounts of both nominal and fault data. However, for domains such as RETS data, the amount of anomalous data that is actually available is relatively small, making most supervised learning methods rather ineffective, and in general met with limited success in anomaly detection. The fundamental problem with existing approaches is that they assume that the data are iid, i.e., independent and identically distributed, which is violated in typical RETS data. None of these techniques naturally exploit the temporal information inherent in time series data from the sensor networks. There are correlations among the sensor readings, not only at the same time, but also across time. However, these approaches have not explicitly identified and exploited such correlations. Given these limitations of model-free methods, there has been renewed interest in model-based methods, specifically graphical methods that explicitly reason temporally. The Gaussian Mixture Model (GMM) in a Linear Dynamic System approach assumes that the multi-dimensional test data is a mixture of multi-variate Gaussians, and fits a given number of Gaussian clusters with the help of the wellknown Expectation Maximization (EM) algorithm. The parameters thus learned are used for calculating the joint distribution of the observations. However, this GMM assumption is essentially an approximation and signals the potential viability of non-parametric density estimators. This is the key idea underlying the new approach.

Solano, Wanda↗

Testing the Accuracy of Data-Driven MHD Simulations of Active Region Evolution

Models for the evolution of the solar coronal magnetic field are vital for understanding solar activity, yet the best measurements of the magnetic field lie at the photosphere, necessitating the development of coronal models which are "data-driven" at the photosphere. We present an investigation to determine the feasibility and accuracy of such methods. Our validation framework uses a simulation of active region (AR) formation, modeling the emergence of magnetic flux from the convection zone to the corona, as a ground-truth data set, to supply both the photospheric information and to perform the validation of the data-driven method. We focus our investigation on how the accuracy of the data-driven model depends on the temporal frequency of the driving data. The Helioseismic and Magnetic Imager on NASA's Solar Dynamics Observatory produces full-disk vector magnetic field measurements at a 12-minute cadence. Using our framework we show that ARs that emerge over 25 hours can be modeled by the data-driving method with only approximately 1 percent error in the free magnetic energy, assuming the photospheric information is specified every 12 minutes. However, for rapidly evolving features, under-sampling of the dynamics at this cadence leads to a strobe effect, generating large electric currents and incorrect coronal morphology and energies. We derive a sampling condition for the driving cadence based on the evolution of these small-scale features, and show that higher-cadence driving can lead to acceptable errors. Future work will investigate the source of errors associated with deriving plasma variables from the photospheric magnetograms as well as other sources of errors, such as reduced resolution, instrument bias, and noise.

Leake, James E.↗

Thermal Data-driven Model Reduction for Enhanced Battery Health Monitoring

Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.

Li ion batteries↗