Search NASA⌕ Search

SEARCH · Search NASA

Results for “Databank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A computerized databank of decompression sickness incidence in altitude chambers

This report describes a hypobaric decompression sickness databank (HDSD) for use with personal computers. The databank consolidates some of the decompression sickness (DCS) information that has accumulated from altitude chamber tests from 1942 to the present. The information was transcribed to a data collection form, screened for accuracy and duplication, and then added to the databank through a computer keyboard. The databank consists of two files; 63 fields contain details of the test conditions in the altitude chamber, the outcome of the test in terms of DCS and venous gas emboli, the physical characteristics of the group of subjects who underwent the test, and the denitrogenation procedures prior to decompression. The HDSD currently contains 378 records that represent 130,012 altitude exposures from 80 sources: scientific journal articles, government and contractor reports, and chapters from books.

Conkin, Johnny↗

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery↗

The International Surface Pressure Databank version 2

The International Surface Pressure Databank (ISPD) is the world's largest collection of global surface and sea-level pressure observations. It was developed by extracting observations from established international archives, through international cooperation with data recovery facilitated by the Atmospheric Circulation Reconstructions over the Earth (ACRE) initiative, and directly by contributing universities, organizations, and countries. The dataset period is currently 1768–2012 and consists of three data components: observations from land stations, marine observing systems, and tropical cyclone best track pressure reports. Version 2 of the ISPD (ISPDv2) was created to be observational input for the Twentieth Century Reanalysis Project (20CR) and contains the quality control and assimilation feedback metadata from the 20CR. Since then, it has been used for various general climate and weather studies, and an updated version 3 (ISPDv3) has been used in the ERA-20C reanalysis in connection with the European Reanalysis of Global Climate Observations project (ERA-CLIM). The focus of this paper is on the ISPDv2 and the inclusion of the 20CR feedback metadata. The Research Data Archive at the National Center for Atmospheric Research provides data collection and access for the ISPDv2, and will provide access to future versions.

54 ENVIRONMENTAL SCIENCES↗

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

Microcircuit radiation effects databank

This databank is the collation of radiation test data submitted by many testers and serves as a reference for engineers who are concerned with and have some knowledge of the effects of the natural radiation environment on microcircuits. It contains radiation sensitivity results from ground tests and is divided into two sections. Section A lists total dose damage information, and section B lists single event upset cross sections, I.E., the probability of a soft error (bit flip) or of a hard error (latchup).

Source record↗

Using the Saturn V and Titan III Vibroacoustic Databanks for Random Vibration Criteria Development

This is an update to TN D-7159, "Development and Application of Vibroacoustic Structural Data Banks in Predicting Vibration Design and Test Criteria for Rocket Vehicle Structures", which was originally published in 1973. Errors in the original document have been corrected and additional data from the Titan III program have been included. Methods for using the vibroacoustic databanks for vibration test criteria development are shown, as well as all of the data with drawings and pictures of the measurement locations. An Excel spreadsheet with the data included is available from the author.

Ferbee, R C.↗

Heat-Exchange in One-Phase Liquid-Metal Flows: Databank (Temperature Distribution in Circular Pipes)

In order to develop accurate methods of calculating heat-exchange in forced channel flows, it is necessary to have knowledge about the temperature distribution over the cross section in differ layers of the flow. For ordinary liquids (gas, water, where the Prandtl number Pr ~ 1), such measurements are difficult to perform because of the small thickness of the boundary layer. The problem simplifies for liquid metals, where Pr << 1. This article contains the format of the data as well as an analysis of the primary data from 37 home and foreign works (mercury, sodium-potassium alloy, sodium, lithium, lead-bismuth alloy). The data are presented in electronic form.

42 ENGINEERING↗

A Free Spectroscopic Databank of Optical Constants for Use in Optics Education and Modeling: complex refractive index data n and k from 1.0 to 25 um

The reflectance spectra of solid and liquids can be complicated since they depend not only on absorption, but also on the refraction, reflection, and scattering of light, all of which are wavelength dependent. The physical form and morphological effects associated with solid and liquid samples are thus known to affect their reflectance spectra in a non-linear fashion, particularly in the infrared. Measuring the optical constants n(?) and k(?) represents an alternative approach, allowing one to model these many effects and thus requiring fewer laboratory measurements. In this paper an overview is presented of the protocols used to measure the n/k optical constants, particularly for liquids. For the liquids, a multiple path length measurements approach is employed, and in this paper we demonstrate the method to determine the complex optical constants n(?) and k(?) of squalene. The resultant calculated spectra of 1 µm and 100 µm thick layers of squalene on an aluminum substrate as derived from the experimental n(?) and k(?) values are shown to demonstrate such effects. The public availability of the n(?)/k(?) data as well as solids hemispherical reflectance data are also discussed.

optical constants, refractive index, solids, Liqui↗

Microcircuit radiation effects databank

Radiation test data submitted by many testers is collated to serve as a reference for engineers who are concerned with and have some knowledge of the effects of the natural radiation environment on microcircuits. Total dose damage information and single event upset cross sections, i.e., the probability of a soft error (bit flip) or of a hard error (latchup) are presented.

Source record↗

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting the heat release variability of Li-ion cells under thermal runaway with few or no calorimetry data

Accurate measurement of the variability of thermal runaway behavior of lithium-ion cells is critical for designing safe battery systems. However, experimentally determining such variability is challenging, expensive, and time-consuming. Here, we utilize a transfer learning approach to accurately estimate the variability of heat output during thermal runaway using only ejected mass measurements and cell metadata, leveraging 139 calorimetry measurements on commercial lithium-ion cells available from the open-access Battery Failure Databank. We show that the distribution of heat output, including outliers, can be predicted accurately and with high confidence for new cell types using just 0 to 5 calorimetry measurements by leveraging behaviors learned from the Battery Failure Databank. Fractional heat ejection from the positive vent, cell body, and negative vent are also accurately predicted. We demonstrate that by using low cost and fast measurements, we can predict the variability in thermal behaviors of cells, thus accelerating critical safety characterization efforts.

25 ENERGY STORAGE↗

Transferable Hirshfeld atom model for rapid evaluation of aspherical atomic form factors

Form factors based on aspherical models of atomic electron density have brought great improvement in the accuracies of hydrogen atom parameters derived from X-ray crystal structure refinement. Today, two main groups of such models are available, the banks of transferable atomic densities parametrized using the Hansen–Coppens multipole model which allows for rapid evaluation of atomic form factors and Hirshfeld atom refinement (HAR)-related methods which are usually more accurate but also slower. In this work, a model that combines the ideas utilized in the two approaches is tested. It uses atomic electron densities based on Hirshfeld partitions of electron densities, which are precalculated and stored in a databank. This model was also applied during the refinement of the structures of five small molecules. A comparison of the resulting hydrogen atom parameters with those derived from neutron diffraction data indicates that they are more accurate than those obtained with the Hansen–Coppens based databank, and only slightly less accurate than those obtained with a version of HAR that neglects the crystal environment. The advantage of using HAR becomes more noticeable when the effects of the environment are included. To speed up calculations, atomic densities were represented by multipole expansion with spherical harmonics up to l = 7, which used numerical radial functions (a different approach to that applied in the Hansen–Coppens model). Calculations of atomic form factors for the small protein crambin (at 0.73 Å resolution) took only 68 s using 12 CPU cores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of New Additions to OLI Software in Predicting Mercuric and Mercurous Species in Liquid Waste Operations

Speciation of mercury during the pretreatment steps of tank waste processing is critical to successful mercury removal prior to vitrification during Liquid Waste Operations (LWO) at SRS. OLI software has been used to predict mercury speciation and activity throughout LWO. The OLI software operates based on a thermodynamic framework called the Mixed Solvent Electrolyte (MSE) framework. The MSE framework allows prediction in theoretically infinitely dilute to concentrated mixtures (e.g., purely solute solutions). Before modification to the MSE framework databanks, certain critical mercury species were missing in the MSE databank, and some thermodynamic data needed to be updated for the OLI software to accurately predict mercury chemical species in SRS waste tanks. To better reflect streams across LWO, new mercury species were integrated into the MSE database. To evaluate the changes to the OLI MSE framework per the Technical Task Request (TTR) and the Task Technical and Quality Assurance Plan (TTQAP), waste stream compositions from Tanks 38, 43, and Tank 50 decontaminated salt solution (DSS) were used as model inputs. Models were developed and executed using both the old and new databases. Compositional analyses from caustic Tank 50 DSS and caustic Tanks 38 and 43 were used as the input streams. These streams represent the most comprehensive chemical data sets where both mercury and tank constituents were measured together. Results for Tank 50 DSS predict HgO as the predominant species in both databases. Both methyl and dimethyl Hg species are present when the new database is ‘on’ and are not predicted with the new database turned ‘off’. The new database predicts a greater amount of HgO and a greater fraction of it in the solid phase. Pourbaix diagrams (potential vs. pH) generated for each Tank 50 DSS were identical regardless of which database was used. Elemental Hg and HgO were predicted in the water stable region under basic conditions. Tanks 38 and 43 follow similar trends as the Tank 50 DSS models. Unlike Tanks 38 and 50 DSS, the Tank 43 Pourbaix plot shows a region of stability for an aqueous HgOHCO3 - species between approximately pH 7-11. In all streams, when MeHg+ is included in the inputs, the new database predicts aqueous MeHgOH as the dominant species. If elemental or dimethyl mercury is in the waste stream, the new database model predicts they are unchanged and remain in those states and quantities. Additionally, the total mercury values are reported for both the measured input data and the OLI output data for all considered tanks. The summary indicates that the percentage error between the measured and calculated values is less than 1% in all cases The reconciliations and generation of the Pourbaix diagrams for Tank 50 DSS took approximately ten times longer with the new database ‘on’. In addition, over the course of that time, models with the new database ‘on’ were more likely to crash or display an error. Some modest performance improvements were noted when modeling with an i7 processor versus an i5. An example error is found in Appendix A. Furthermore, Appendix B provides V&V for two chemical systems analyzed with the OLI software, results were satisfactory. It is recommended to utilize the new databases (i.e., HCO.ddb and SR-Hg.ddb) in future Savannah River Mission Completion applications of OLI to represent pseudo steady-state. Furthermore, the integration and utilization of the new databases (i.e., HCO.ddb and SR-Hg.ddb) in modeling applications (e.g., Aspen) is also recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Open Source Release of NJOY2016 and NJOY21

NJOY has been the standard for nuclear data processing for many decades. NJOY is a comprehensive computer code used to produce point-wise and multigroup nuclear data application libraries from cross sections and related quantities obtained from evaluated nuclear data in the Evaluated Nuclear Data Format (ENDF). NJOY was first publicly released in 1977 and distributed by what is now the Radiation Safety Information Computational Center (RSICC) at Oak Ridge National Laboratory and the National Energy Software Center (NESC) at Argonne National Laboratory. From that time until the release of NJOY2012, NJOY has been distributed by RSICC and made available to researchers outside the United States by agreements between RSICC and the NEA Databank. NJOY2012 was distributed by the Feynman Center at Los Alamos National Laboratory which did not have agreements with the NEA Databank, thus making it more difficult for non US citizens to obtain copies of NJOY2012. Furthermore, NJOY has had export control restrictions preventing some researchers from obtaining NJOY at all. Two new versions of NJOY have been released, NJOY2016 and NJOY21, in January of 2017. Both NJOY2016 and NJOY21 have been released with no export control restrictions and are distributed with an open-source license. This is a big departure from previous releases and impacts not only who has access to NJOY, but also how updates are made available to users and how collaboration is facilitated among interested developers. In addition to distributing NJOY2016 and NJOY21 with an open-source license, these two new versions provide new capabilities for NJOY which will maintain NJOY as the standard for nuclear data processing into the foreseeable future. We report in this summary about the changes that come with these two new versions of NJOY and how this impacts the users and long-time contributors to NJOY.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Next Generation Electromagnetic Pump Analysis Tools (PLM DOC-0005-2188). Final Report

This report provides the broad historical review of EM Pump development and details of MATRIX development under this project. This report summarizes the efforts made to modernize the legacy performance models used in previous EM Pump designs and the improvements made to the analysis tools. This report provides information on Tasks 1, 3, and 4 of the entire project. The research for Task 4 builds upon Task 1: Update EM Pump Databank and Task 3: Modernize the Existing EM Pump Analysis Model, which are summarized within this report. Where research for Task 2: Insulation Materials Development and Evaluation identified parameters applicable to the analysis model with Task 4, the analysis code was updated, and analyses were made for additional materials. The important design variables for the manufacture and operation of an EM Pump that the model improvement can evaluate are: space constraints; voltage capability of insulation system; maximum flux density through iron; flow rate and outlet pressure; efficiency and manufacturability. The development of the next-generation EM Pump analysis tools during this two-year program provides information in three broad areas: Status of analysis model development; Improvements made to older simulations; and Comparison to experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Technical Report: Electromagnetic Pump Insulation Materials Development and Testing (PLM-DOC-0005-2465) Report # DOEGEHB00613

Final Technical Report: Electromagnetic Pump Insulation Materials Development and Testing (Report # DOEGEHB00613) summarizes the information gathered from the analysis of the 160 m3/min EM Pump insulation that was tested in 2000-2002 and additional evaluations of new resilient, engineered insulation system evaluated and tested at both GRC and ANL. This report provides information on Tasks 1 and 2 of the entire project. This report also provides information in three broad areas: Historical and current data; Conclusions based on test data; and Insulation specifications for use in EM Pumps. The research for Task 2 builds upon Task 1: Update EM Pump Databank, which is summarized within this report. Where research for Task 3 and 4 Next-Generation EM Pump Analysis Tools identified parameters or analysis model that benefits Task 2 research, those items are noted within this report. The important design variables for the manufacture and operation of an EM Pump that the insulation research can evaluate are: space constraints; voltage capability of insulation system; maximum flux density through iron; flow rate and outlet pressure; efficiency and manufacturability. The development summary of the Electromagnetic Pump Insulation Materials Development and Testing was completed to include: Historical and current data; Conclusions based on test data; and Insulation specifications for use in EM Pumps.

36 MATERIALS SCIENCE↗

Dynamics of Intra-Cell Thermal Front Propagation in Lithium-Ion Battery Safety Issues

Thermal runaway (TR), a critical failure mode in lithium-ion batteries (LIBs), poses significant safety risks and hinders wider application of LIBs. TR typically begins at a localized heat source and spreads across the cell. Understanding thermal front propagation (TFP) characteristics, such as front and velocity, is crucial for assessing energy release and temperature distribution for battery hazardous estimation. Recent studies assume that TR within cells propagates at a near-constant velocity, based on the reaction kinetics and thermal properties. Here, in this study, an intra-battery TR model is further proposed and it indicates that TFP velocity stabilizes when the front is distanced from the heat source. Theoretical estimates for propagation velocity and front are developed and validated through numerical simulations and experimental tests from the NREL Battery Failure Databank. The energy release rate during TFP and the impact of preheating based on a point heat source are explored. This work clarifies the long-standing clouds of the thermal font propagation behaviors within the single cell, highlights the power and beauty of mathematics modeling to describe the complicated thermal behaviors, and provides important guidelines for thermal hazardous understanding for next-generation batteries.

25 ENERGY STORAGE↗