Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dean vortex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Large enhancement of the in-field critical current density of YBCO coated conductors due to composite pinning landscape

YBa 2 Cu 3 O 7 -based coated conductors (CCs) achieve the highest critical current densities (J c ) of any known superconductor and are a key technology for applications such as rotatory machines, high-field magnets and power transmission. Incorporation of nano-sized non-superconducting second phases as additional vortex pinning centers has been considered the most amenable route to further enhance J c at an industrial scale, and has been successfully used in commercial CCs. The resulting pinning landscape is quite complex, with both synergistic and competing interactions among the various types of defects. Particle irradiation, on the other hand, allows for a controlled post-processing incorporation of a well-defined defect morphology. We have previously shown that irradiation with protons and other light ions can further enhance the in-field J c in commercial state-of-the-art CCs. Here we develop a combined irradiation process that increases J c above values previously achieved by irradiating with only one species. Our new approach involves sequentially irradiating with 250 MeV Au ions and 4 MeV protons. For example, at T ~ 27 K (liquid neon) and μ 0 H ~ 4 T, a region of interest for rotatory machines applications, we obtain J c ~ 5 MA cm -2 , which is about 40% higher than the values produced by the individual irradiations. Finally, we conclude that this is due to the synergistic pinning effects of the introduced splayed, non-uniform columnar defects and small clusters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The effect of entrance flow development on vortex formation and wall shear stress in a curved artery model

In this work, we numerically investigate the effect of entrance condition on the spatial and temporal evolution of multiple three-dimensional vortex pairs and the wall shear stress distribution in a curved artery model. We perform this study using a Newtonian blood-analog fluid subjected to a pulsatile flow with two inflow conditions. The first flow condition is fully developed while the second condition is undeveloped (i.e., uniform). We discuss the connection along the axial direction between regions of organized vorticity observed at various cross sections of the model and compare results between the different entrance conditions. We model a human artery with a simple, rigid 180° curved pipe with a circular cross section and constant curvature, neglecting the effects of taper, torsion, and elasticity. Numerical results are computed from a discontinuous high-order spectral element flow solver. The flow rate used in this study is physiological. We observe differences in secondary flow patterns, especially during the deceleration phase of the physiological waveform where multiple vortical structures of both Dean-type and Lyne-type coexist. The results indicate that decreased axial velocities under an undeveloped condition produce smaller secondary flows that ultimately inhibit growth of any interior flow vortices. We highlight the effect of the entrance condition on the formation of these structures and subsequent appearance of abnormal inner wall shear stresses, which suggest there may be a lower prevalence of cardiovascular disease in curved arteries where the flow is rather undeveloped—a potentially physiologically significant result to help understand the influence of blood flow development on disease.

60 APPLIED LIFE SCIENCES↗

An LES study of secondary motion and wall shear stresses in a pipe bend

In this study, large-eddy simulations (LES) of a single-phase, turbulent flow in a 90 ° pipe bend are performed at three Reynolds numbers (5300, 27 000, and 45 000) to investigate the correlation between secondary flow motion and wall shear stresses, which is suspected to be a potential mechanism responsible for material erosion. The isothermal flows are validated against available experimental and numerical data first. The snapshot proper orthogonal decomposition (POD) is applied for the medium and high Reynolds number flows to identify the secondary flow motions and the oscillation of the Dean vortices that are found to cause swirl-switching. Distinguished frequencies of the POD time coefficients at Strouhal numbers of 0.25 and 0.28 are identified for Reynolds numbers at 27 000 and 45 000, respectively. Moreover, shear stress on the pipe wall and the associated power spectral density are obtained and shown to have the same oscillating frequency as the swirl-switching.

42 ENGINEERING↗