Search NASA⌕ Search

SEARCH · Search NASA

Results for “Decay Curve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Decay Curve Correction Analysis Report

The decay curve analysis that is done on the short-lived radionuclide gas samples is used to differentiate between gaseous radionuclides that have the same characteristic gamma decay energy, 511 kiloelectron-volts (keV). A sample of stack gas is isolated and the total counts in the 511 keV peak are counted repeatedly in 10-second intervals to evaluate the decay rate of the sample over time. Analysis of this decay data required a series of steps. First, a raw data report is generated by the gamma acquisition system, based on an analysis template within the acquisition software. The data report file was then loaded into Microsoft Word, and a macro was used to perform minor formatting (remove colons and insert tabs between data columns) to allow analysis within Excel. The file is then saved as a text file at this point. The text file is then uploaded into Excel and a series of macros are used to add labels, calculate radioactive decay constants, and analyze the gamma decay data using linear regression techniques. The analysis template has been used since 1998 for stack 53000303 (TA-53, building 0003, exhaust stack 03) and 2000 for stack 53000702. The overall process, including the gamma report format and the macros used in Word and Excel for processing the report, had remained unchanged until 2015. In October of 2015, staff made a change to the report template in the gamma acquisition software which resulted in an error in the calculations later performed by the Excel macro. This error was not caught until a more in-depth review of the analysis took place regarding 2020 data. This report covers a much more complete review of the issue that occurred regarding the decay curve analysis, a review of the calculations completed to correct the issue, a review of the updated decay curve analysis process, and recommendations for moving forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detecting the dynamical state of the atmosphere from the orbital decay of the ODERACS spheres

The orbital decay curve of a satellite having constant cross-sectional area and in circular orbit can furnish valuable information regarding the dynamical state of the atmosphere. It is shown that a rectilinear decay curve having constant downward slope (zero curvature) should indicate that the atmosphere was undergoing compression during that period. A decay curve having concavity upwards (positive curvature) will strongly indicate that the atmosphere was in a contracting phase. A decay curve with downward concavity (negative curvature) may indicate an expanding, a stationary or a contracting atmosphere. This theory, when applied to the orbital decay of the Orbital Debris Radar Calibration Spheres (ODERACS) satellites, indicates that during the period from Day 90 through Day 240 in the year 1994, the atmosphere was very definitely in a compression mode. During this period, ODERACS Sphere 1 faced nearly constant densities while Sphere 6 actually encountered progressively smaller air densities as they descended. The atmospheric scale height as calculated from the orbital data of Spheres 1 and 6 diminished steadily during the same period. It is shown that Spheres 1 and 6 descended faster and slower respectively, than the level of constant air density equal to 5 x 10 kg/m . During a brief period from Day 240 through Day 290, the atmosphere reversed to a strongly expanding mode. Thereafter, the atmosphere reverted back to a compression mode from Day 290 through Day 390, 1994.

Tan, Arjun↗

Measurements of recombination of electrons with HCO(plus) ions

Recombination coefficients of electrons with HCO(+) ions were determined with a microwave afterglow/mass spectrometer apparatus. Afterglow measurements of electron density decays in neon-hydrogen-carbon monoxide mixtures are correlated with the decay of mass-identified ion currents to the wall of the microwave cavity. At the appropriate partial pressures of hydrogen and carbon monoxide in the mixture, the ion HCO(+) dominates the ion composition and its wall current approximately tracks the electron density decay curve. From recombination controlled electron density decay curves, the values alpha (HCO(+)) = (3.3 + or - 0.5) and (2.0 + or - 0.3) 0.0000001 cu cm/sec are obtained at 205 and 300 K, respectively. The implications of these results for models of polyatomic molecule formation in dense interstellar clouds are briefly discussed.

Leu, M. T.↗

Measurements of recombination of electrons with H3(plus) and H5(plus) ions

The electron-ion recombination coefficients for H3(+) and H5(+) ions were determined by means of a microwave afterglow/mass spectrometer apparatus. Measurements of electron density decays in helium-hydrogen mixtures are correlated with the decay of mass-identified ion currents to the wall of the microwave cavity. At low partial pressures of hydrogen in the mixture, the ion H3(+) dominates the ion composition and the ion wall current tracks the electron density decay curves. From recombination controlled electron density decay curves, the values alpha (H3(+)) = (2.9 + or - 0.3), (2.3 + or - 0.3), and (2.0 + or - 0.2) x 0.0000001 cu cm per sec, are obtained at 205, 300 and 450 K, respectively. At higher partial pressures of hydrogen and low temperatures, where (H5(+)) is the dominant ion, the value alpha (H5(+)) = (3.6 + or - 1.0) x 0.0000001 cu cm per sec is obtained at 205 K. The implications of these results concerning ionization levels in the atmospheres of the outer planets and in the interstellar medium are discussed.

Leu, M. T.↗

Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C

This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al2O3:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F+ -centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al2O3:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗

Half-life determination of heavy ions in a storage ring considering feeding and depleting background processes

Heavy-ion storage rings have relatively large momentum acceptance which allows for multiple ion species to circulate at the same time. This needs to be considered in radioactive decay measurements of highly charged ions, where atomic charge exchange reactions can significantly alter the intensities of parent and daughter ions. In this study, we investigate this effect using the decay curves of ion numbers in the recent 205 Tl 81+ bound-state beta decay experiment conducted using the Experimental Storage Ring at GSI Darmstadt. To understand the intricate dynamics of ion numbers, we present a set of differential equations that account for various atomic and nuclear reaction processes—bound state beta decay, atomic electron recombination and capture, and electron ionization. By incorporating appropriate boundary conditions, we develop a set of differential equations that accurately simulate the decay curves of various simultaneously stored ions in the storage ring: 205 Tl 81+ , 205 Pb 81+ , 205 Pb 82+ , 200 Hg 79+ , and 200 Hg 80+ . Through a quantitative comparison between simulations and experimental data, we provide insights into the detailed reaction mechanisms governing stored heavy ions within the storage ring. Our approach effectively models charge-changing processes, reduces the complexity of the experimental setup, and provides a simpler method for measuring the decay half-lives of highly charged ions in storage rings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Re-examination of a Classic Experiment to Measure the Positronium-Helium Cross Section

In 1975, before the advent of positronium beams, a clever experiment was carried out in an attempt to measure low-energy Ps-atom scattering cross-sections, especially that of Ps-He. A series of parallel thin plates was placed in the vessel containing the sample of gas, and positrons were allowed to enter the chamber from a radioactive source. The time spectrum of annihilation radiation was observed in the traditional way, and the pickoff annihilation due to thermalized Ps striking one of the plates was to be the special feature of the experiment. Using a diffusion analysis the authors derived cross- sections for several gases, and for helium the value obtained was sigma = 0.0166 pi(alpha)(sub o, sup 2). Even then this value was thought to be very much too small, while recent measurements and some calculations suggest a more reasonable value would be sigma = 3 to 13 pi(alpha)(sub o,sup 2). It has always been puzzling that an apparently well-designed experiment should give such an unsatisfactory result. We have now re-examined the analysis of the data with some interesting consequences which may explain the discrepancy. Two main observations support our re-analysis. First, we note that the mean free path for Ps-He scattering would be quite long if the cross-section were as small as that quoted above; the diffusion method itself would seem to be questionable. For the larger values, however, there would be no such problem. Second, it was assumed that when the annihilation rate had settled down and was following an exponential decay curve the asymptotic solution of the diffusion equation had been reached. We find, instead, that a superposition of exponentials can accurately represent the decay curve, consistent with the higher cross-section value.

Drachman, Richard J.↗

The natural thermoluminescence of meteorites. VI - Carbon-14, thermoluminescence and the terrestrial ages of meteorites

A relationship is noted between the natural thermoluminescence (TL) levels and the C-14-derived terrestrial ages for meteorite finds from the U.S. Prairie States and Roosevelt County, NM; those in the Sahara are also in accord with calculated TL decay curves, for 'storage' temperatures equal to the approximate average annual temperatures at individual sites. This discussion is limited to the empirical correspondence between the two methodologies, and to theoretical decay curves for a single 'average' ordinary chondrite.

Benoit, P. H.↗

Simple new methods for deducing lifetimes in recoil distance Doppler-shift measurements

In this work, new approaches for lifetime determination using data from recoil distance Doppler-shift experiments are presented based on the fundamental properties of the functions describing the time evolution of the population of excited nuclear states. To some extent, one of them represents a contraction of the well-known Differential decay-curve method (DDCM) by using the most reliable data point [the maximum of the $n_i(t)$ function describing the population of level $\textit{i}$ in time] and a purely numerical procedure avoiding any fitting of decay curves. The combination with the standard DDCM analysis is promising for improving the reliability and the precision of the results for the lifetimes obtained. The novel part of the approach consists of using a chain of equations at the consecutive maxima of the ni(t) functions, which allow us to precisely determine the ratio of the lifetimes of two consecutive levels and, in the case where one of these lifetimes is known, to determine the unknown one. In addition, a simple integral derivation of the lifetime is presented involving the peak areas measured at different distances, and an application of the first moments (expectation values and centroids in time) of the $n_i(t)$ functions for determining lifetimes is also demonstrated to be useful.

47 OTHER INSTRUMENTATION↗

Thermospheric O I 844.6-nm emission in twilight

The thermospheric O I 844.6-nm column emission rate was measured over Toronto, a midlatitude station, in the autumn of 1991 using an imaging Fabry-Perot spectrometer. Twilight decay curves were measured on four clear evenings when the solar zenith angle was between 95 degs and 104 degs, giving corresponding column emission rates between 874 R and 130 R at 20 degs elevation angle in the azimuth of the Sun. The expected decay curves were calculated from the field line interhemisperic plasma model assuming only photoelectron impact excitation as the production mechanism with a cross section appropriate to an optically thin atmosphere. The agreement was good when the solar and geomagnetic activity levels were low to moderate, but the emission rate was overestimated during high activity periods. The comparison indicates that the photoelectron impact mechanism with a thin-atmosphere cross section is sufficient to explain the twilight decay of the thermospheric O I 844.6-nm emission.

Bahsoun-Hamade, F.↗

Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C

The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

Thermoluminescent Dosimetry/instrumentation/method↗

Study of Luminescence Characteristics of Trivalent Terbium in Silicate Glass

An important use of silicate glasses doped with terbium oxide (Tb2O3) is their use as fiber optic sensors for high-resolution imaging applications requiring the detection of x-rays (e.g. tomography and radiography). The x-ray radiation is absorbed by the glass, producing electron-hole pairs (excitons). The excitons migrate through the glass matrix and then recombine, emitting characteristic Tb(3+) luminescence in the optical wavelength region. This emission is due to forbidden transitions of 4f electrons and therefore has a long decay time. Long decay time is undesirable when imaging transient events since it results in blurring in time of the images. It has been reported elsewhere that in crystals Tb(3+) ions can act both as luminescence centers and as fluorescence traps. These traps can capture excitons and delay their recombination. This delayed fluorescence is seen as a long lived, secondary component to the luminescence decay curve, or afterglow. Such a secondary decay component to the luminescence decay of Tb(3+) has been observed before in soda glass following pulsed optical excitation. In order to determine the conditions under which afterglow occurs, an understanding of the material's luminescent properties is required.

West, Mike S.↗

Development of the multi-purpose Cologne Compact Differential Plunger (CoCoDiff) for the measurement of nuclear level lifetimes with the Recoil Distance Doppler-shift method

Here, a new 3-foil plunger device, the Cologne Compact Differential (CoCoDiff) plunger has been built and commissioned. Due to its compact size, it can be used together with many different spectrometers and auxiliary detectors. As a commissioning experiment, level lifetimes of the $2^{+}_{1}$ and the $4^{+}_{1}$ excited states of 50 Cr have been measured, using the Differential Decay Curve method (DDCM). A derivation is given on how this method can be applied to a differential plunger measurement, in order to measure distances for lifetimes from two different regions of sensitivity at the same time. The commissioning experiment took place at the Cologne FN tandem accelerator, using the reaction 24 Mg( 32 S,4p2n) 50 Cr. Lifetimes, deduced from this measurement, agree well with literature values from earlier measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation of self-subtraction holography in LiNbO3

A sample having self subtraction characteristics that were very promising was tested in depth: hologram formation times were on the order of 150 sec, the null signal was less than 2.5% of the peak signal, and no fatigue nor instability was detected over the span of the experiments. Another sample, fabricated with, at most, slight modifications did not perform nearly as well. In all samples, attempts to improve self subtraction characteristics by various thermal treatments had no effects or adverse effects, with one exception in which improvement was noted after a time delay of several days. A theory developed to describe self subtraction showed the observed decrease in beam intensity with time, but the shape of the predicted decay curve was oscillatory in contrast to the exponential like decay observed. The theory was also inadequate to account for the experimental sensitivity of self subtraction to the Bragg angle of the hologram. It is concluded that self subtraction is a viable method for optical processing systems requiring background discrimination.

Vahey, D. W.↗

Radiation environment for rendezvous and docking with nuclear rockets

Radiation environment data for the NERVA engine are provided which may be utilized in estimating radiation exposures associated with various space maneuvers. Spatial distributions of neutron and gamma tissue kerma rates produced during full thrust operation of the engine are presented. Final rendezvous with an orbiting space station would be achieved subsequent to full thrust operation during a period of 10 or more hours duration in which impulse is delivered by the propellant used for removal of decay heat. Consequently, post operation radiation levels are of prime importance in estimating space station exposures. Maps of gamma kerma rates around the engine are provided for decay times of 4 and 24 hours after a representative firing. Typical decay curves illustrating the dependence of post operation kerma rates on decay time and operating history are included. Examples of the kerma distributions around the engine which result from integration over specific exposure periods are shown.

Rogers, D. R.↗

A search for periodicity in the x ray spectrum of black hole candidate A0620-00

The archived data from the SAS-3 observations of the X-ray nova A0620-00, the best of the stellar blackhole candidates, were exhaustively examined for evidence of variable phenomena correlated with the orbital motion of the binary system of which it is a member. The original analysis of these data was completed before discovery of the binary companion and determination of the orbital period of the system. New interest was drawn to the task of a reexamination of the archive data by the recent discovery of the massive nature of the X-ray source through analysis of the Doppler variations and ellipsoidal light variations of the faint K-star companion by McClintock and Remillard. The archive research, carried out under the supervision of the principal investigator, was the topic of the thesis submitted to the MIT Department of Physics by Kenneth Plaks in partial fulfillment of the requirements for the degree of Master of Science. Plaks' effort was focused on the elimination of fluctuations in the data due to errors in attitude solutions and other extraneous causes. The first products of his work were long-term light curves of the X-ray intensities in the various energy channels as functions of time during the time from outbursts in August 1975 to quiescence approximately 6 months later. These curves, are refined versions of the preliminary results published in 1976 (Matilsky et al. 1976). Smooth exponentials were fitted to these long term light curves to provide the basis for detrending the data, thereby permitting a calculation of residuals derived by subtracting the fitted curve from the data. The residuals were then analyzed by Fourier analysis to search for variations with the period of the binary orbit, namely 7.75 hours. No evidence of an orbital periodicity was found. However, the refined light curve provides a much clearer picture of the outburst and subsequent decay of the X-ray luminosity. In fact, there were two outbursts, each followed by an exponential decay with similar time constants of about 25 days. Previous evidence of a three-oscillation variation with a 7.8 day period were confirmed. Substantial theoretical effort has been devoted to attempts to account for the decay characteristics as the result of the gradual eating up of an accretion disk by a stellar-mass blackhole (e.g., Huang and Wheeler 1989). The improved decay curves will provide significant new constraints on the theoretical analyses.

Clark, George W.↗