Passive thermography is used to monitor small increases in temperature resulting from delamination damage formation in composite hat-stiffened panels during both quasi-static and fatigue loading. It has been observed that rapid damage formation produces heating. This is composed of two heat generation components. The first component is an instantaneous response due to an irreversible thermoelastic strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This produces a transient rise in temperature as the heat diffuses to the surface. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is fitted to the data pixel by pixel, to produce imagery of the damage depth. The results are compared to ultrasonic and X-ray CT data.
Delaminations in composite laminates resulting from impact events may be accompanied by minimal indication of damage at the surface. As such, inspection techniques are required to ensure defects are within allowable limits. Conventional ultrasonic scanning techniques have been shown to effectively characterize the size and depth of delaminations but require physical contact with the structure. Alternatively, a noncontact scanning laser vibrometer may be used to measure guided wave propagation in the laminate structure. A local Fourier domain analysis method is presented for processing guided wavefield data to estimate spatially-dependent wavenumber values, which can be used to determine delamination depth. The technique is applied to simulated wavefields and results are analyzed to determine limitations of the technique with regards to determining defect size and depth. Finally, experimental wavefield data obtained in quasi-isotropic carbon fiber reinforced polymer (CFRP) laminates with impact damage is analyzed and wavenumber is measured to an accuracy of 8.5% in the region of shallow delaminations. Keywords: Ultrasonic wavefield imaging, Windowed Fourier transforms, Guided waves, Structural health monitoring, Nondestructive evaluation
Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.
Previous work has demonstrated that TBC delamination can be monitored by incorporating a thin luminescent sublayer that produces greatly increased luminescence intensity from delaminated regions of the TBC. Initial efforts utilized visible-wavelength luminescence from either europium or erbium doped sublayers. This approach exhibited good sensitivity to delamination of electron-beam physical-vapor-deposited (EB-PVD) TBCs, but limited sensitivity to delamination of the more highly scattering plasma-sprayed TBCs due to stronger optical scattering and to interference by luminescence from rare-earth impurities. These difficulties have now been overcome by new strategies employing near-infrared (NIR) and upconversion luminescence imaging. NIR luminescence at 1550 nm was produced in an erbium plus ytterbium co-doped yttria-stabilized zirconia (YSZ) luminescent sublayer using 980-nm excitation. Compared to visible-wavelength luminescence, these NIR emission and excitation wavelengths are much more weakly scattered by the TBC and therefore show much improved depth-probing capabilities. In addition, two-photon upconversion luminescence excitation at 980 nm wavelength produces luminescence emission at 562 nm with near-zero fluorescence background and exceptional contrast for delamination indication. The ability to detect TBC delamination produced by Rockwell indentation and by furnace cycling is demonstrated for both EB-PVD and plasma-sprayed TBCs. The relative strengths of the NIR and upconversion luminescence methods for monitoring TBC delamination are discussed.
The ability of through-the-thickness stitches to contain damage during a low-velocity impact event and increase the residual strength of stitched panels was investigated in this research. The impact response, spread of interlaminar delaminations, dent depth, surface damage, and static residual strength after impact were studied for carbon-epoxy specimens fabricated from HTS40 TohoTenax standard modulus fibers, stitched together with Vectran 1200 denier thread and infused with API 1078 resin after through-the-thickness stitching. Three different stitch patterns were used to explore the ability to arrest impact damage during and after impact. Simply supported boundary conditions were maintained during the impact testing. Non-destructive evaluations were performed using ultrasonic C-scans and X-ray computed tomography (CT) imaging to determine the shape, size, and location of delaminations. Results indicate that while the dynamic response during the impact event was almost the same for the unstitched specimens and all stitch patterns considered, the extent of delamination and the compression strength after impact varied greatly. For both the 60 J and 80 J impact energies, the delamination area was significantly less for the stitched specimens than for the unstitched specimens, but the range of delamination areas among the stitch patterns was much larger for the lower impact energy than for the greater impact energy. Similarly, while the presence of stitching influenced the compression after impact strength, the strength values for all stitch patterns were very similar. These results are a step toward quantifying the influence of through-the-thickness stitching.
The paper deals with the infrared flash thermography inspection to detect and analyze delamination-like anomalies in nonmetallic materials. It provides information on an IR Contrast technique that involves extracting normalized contrast verses time evolutions from the flash thermography infrared video data. The paper provides the analytical model used in the simulation of infrared image contrast. The contrast evolution simulation is achieved through calibration on measured contrast evolutions from many flat bottom holes in the subject material. The paper also provides formulas to calculate values of the thermal measurement features from the measured contrast evolution curve. Many thermal measurement features of the contrast evolution that relate to the anomaly characteristics are calculated. The measurement features and the contrast simulation are used to evaluate flash thermography inspection data in order to characterize the delamination-like anomalies. In addition, the contrast evolution prediction is matched to the measured anomaly contrast evolution to provide an assessment of the anomaly depth and width in terms of depth and diameter of the corresponding equivalent flat-bottom hole (EFBH) or equivalent uniform gap (EUG). The paper provides anomaly edge detection technique called the half-max technique which is also used to estimate width of an indication. The EFBH/EUG and half-max width estimations are used to assess anomaly size. The paper also provides some information on the "IR Contrast" software application, half-max technique and IR Contrast feature imaging application, which are based on models provided in this paper.
Transient thermography employs preheated surface temperature variations caused by delaminations, cracks, voids, corroded regions, etc. Often, it is enough to detect these changes to declare a defect in a workpiece. It is also desirable to obtain additional information about the defect from the thermal response. The planar size, depth, and thermal resistance of the detected defects are the parameters of interest. In this paper a digital image processing technique is applied to simulated thermal responses in order to obtain the geometry of the inclusion-type defects in a flat panel. A three-dimensional finite difference model in Cartesian coordinates is used for the numerical simulations. Typical physical properties of polymer graphite composites are assumed. Using different informative parameters of the thermal response for depth estimation is discussed.
Results of a defect visualization process based on pulse infrared thermography are presented. Algorithms have been developed to reduce the amount of operator participation required in the process of interpreting thermographic images. The algorithms determine the defect's depth and size from the temporal and spatial thermal distributions that exist on the surface of the investigated object following thermal excitation. A comparison of the results from thermal contrast, time derivative, and phase analysis methods for defect visualization are presented. These comparisons are based on three dimensional simulations of a test case representing a plate with multiple delaminations. Comparisons are also based on experimental data obtained from a specimen with flat bottom holes and a composite panel with delaminations.
The longevity of tribological components in extraterrestrial environments is challenged by abrasive regolith, extreme temperatures, and ionizing radiation. This study evaluates the performance of vacuum plasma sprayed (VPS) Ti-2vol.% hexagonal boron nitride (hBN) coatings applied to joint mechanisms such as rod and slot, ball and socket, and hinge assemblies, fabricated from Al6061 and Ti6Al4V for planetary structures. Coated and uncoated samples were tested under vacuum with lunar regolith simulant (JSC-1A), followed by environmental exposures including electron radiation and thermal cycling. Results show that coated samples consistently outperformed uncoated counterparts across all configurations. Wear depth in coated components was reduced by over 80%, as confirmed by 3D profilometry and surface imaging. SEM analysis revealed severe abrasion and localized plastic deformation in uncoated surfaces, while coated samples retained structural integrity due to synergy of hard protective phases formed during deposition and retained hBN providing solid lubrication in the sliding surface. Coated and exposed samples exhibited smoother actuation profiles and reduced friction, indicating a beneficial "conditioning" effect from environmental exposure. The coatings-maintained performance even on complex geometries with minimal delamination. These findings demonstrate the potential of VPS Ti-hBN coatings to extend the operational life of lunar mechanisms, bridging laboratory-scale tribology with flight-relevant mechanical applications.
The thermographic evaluation of composite structures for delaminations, disbonds, inclusions, porosity and microcracking has proven to be a valuable asset in the field of nondestructive testing. Coupling large area coverage, variable sensitivity and minimal surface contact with a photographic type image representation of structural anomalies; thermography has become a primary inspection method for composite structures. Thermography works well for locating both surface and subsurface defects in most composite systems ranging in thickness of up to 0.25 inch (0.64 cm) or more. The thermographic method for inspection of composite structures typically involves applying an external source of heat to the structure and then recording the changes in the surface heat profile manifested by embedded defects or by material property variations. If these temperature variations are large enough and an infrared camera with sufficient sensitivity is used, then the material or structural abnormality can be detected and referred back to its source. Interpreting the information given in a thermogram, can be a difficult task under ideal circumstances and extremely challenging in a real world setting. Variables including depth, thermal conductivity, orientation and size of the abnormality can all have a great influence on how its heat pattern will be seen by the imager. The work discussed in this paper illustrates how the microstructure of several commonly found defects in composite structures relate to their thermographic image counterpart. Two test cases are studied herein, including a large graphite/epoxy RP-1 fuel tank and a graphite composite cryogenic fuel feedline. The structures used in this study were designed to serve as manufacturing proof of concept specimens and to undergo hydroburst testing to verify manufacturing practices and structural design. Prior to hydrostatic testing the structures underwent 100% thermographic evaluation to ensure that no manufacturing or handling damage was present. Due to a large inclusion found in the feedline, it was pulled from service and dissected without performing the hydroproof The thermographic indications found in the RP-1 tank were below critical limits so it underwent a complete hydroproof loading series and finally a hydroburst. Following the hydroburst samples were cut from the tank in regions where thermography had located damage before the test. These regions were thermographically and then were cross-sectioned and photomicrographed.
Carbon fiber composites are used in a wide range of structural applications due to their excellent specific strength and stiffness. However, the anisotropic mechanical and electrical properties associated with the fibers within each composite layer present challenges, and opportunities, for Nondestructive Testing (NDT) methods used to characterize and assess the structure condition. This includes composite condition after manufacture (such as fiber orientation and density, porosity, delamination, and bond strength) and during usage (such as damage from impact, fiber breakage, thermal exposure or applied stress). Ultrasonic and thermographic methods can address some of these challenges, but eddy current methods provide an alternative method for composite structures that contain a conducting material, such as carbon fibers or a metallic liner. This presentation reviews recent advances in the development of eddy current sensors and arrays for carbon fiber composite NDT and Structural Health Monitoring (SHM) applications. The focus is on eddy current sensor constructs with linear drive windings, such as MWM -Arrays, that induce currents primarily within the linear fibers of the composite. By combining this type of sensor construct with micromechanical models that relate composite constituent properties to measurable sensor responses, insight is obtained into the volumetric distribution of electrical properties within the composite and the associated manufacturing, damage, or strain conditions. With knowledge of the fiber layup, this MWM-Array technology is able to detect damage and strain/stress as a function of depth and fiber orientation. This work has been funded by NASA, NA V AIR and the Army for applications ranging from composite overwrapped pressure vessels (COPVs) to aircraft structures and rotorcraft blades. This presentation will specifically present background on the MWM-Array technology, results from the micromechanical modeling effort, and results from ongoing efforts for high resolution imaging and volumetric strain sensing.