Effective delayed neutron fraction and delayed neutron reaction rate calculations with MCNPX.
No abstract prepared.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
The delayed neutron fraction, which is necessary for the safe operation of reactors, varies by fissionable material and neutron spectrum. A prompt fission neutron spectrum has been included in the SCALE 6.2 release to account for the removal of delayed neutrons from precursor materials from the neutron balance. This paper describes how experimental measurements from criticality safety benchmarks were used to validate the SCALE calculational procedure for the delayed neutron fraction. Additionally, the effect of nuclear data uncertainty on the KENO calculation of β eff was examined with the SAMPLER sequence.
Precise knowledge of effective delayed neutron fraction ({beta}{sub eff}) and of the corresponding uncertainty is important for reactor safety analysis. The interest in developing the methodology for estimating the uncertainty in {beta}{sub eff} was expressed in the scope of the UAM project of the OECD/NEA. A novel approach for the calculation of the nuclear data sensitivity and uncertainty of the effective delayed neutron fraction is proposed, based on the linear perturbation theory. The method allows the detailed analysis of components of {beta}{sub eff} uncertainty. The procedure was implemented in the SUSD3D sensitivity and uncertainty code applied to several fast neutron benchmark experiments from the ICSBEP and IRPhE databases. According to the JENDL-4 covariance matrices and taking into account the uncertainty in the cross sections and in the prompt and delayed fission spectra the total uncertainty in {beta}eff was found to be of the order of {approx}2 to {approx}3.5 % for the studied fast experiments. (authors)
Measurement of effective delayed neutron fraction for Zero Power Reactor I
The critical decay constant (B/A), delayed neutron fraction (B) and generation time (A) of the Minerve reactor were measured by the Paul Scherrer Institut (PSI) and the Commissariat a l'Energie Atomique (CEA) in September 2014 using the Feynman-alpha and Power Spectral Density neutron noise measurement techniques. Three slightly subcritical configuration were measured using two 1-g {sup 235}U fission chambers. This paper reports on the results obtained by PSI in the near critical configuration (-2g). The most reliable and precise results were obtained with the Cross-Power Spectral Density technique: B = 708.4±9.2 pcm, B/A = 79.0±0.6 s{sup -1} and A 89.7±1.4 micros. Predictions of the same kinetic parameters were obtained with MCNP5-v1.6 and the JEFF-3.1 and ENDF/B-VII.1 nuclear data libraries. On average the predictions for B and B/A overestimate the experimental results by 5% and 11%, respectively. The discrepancy is suspected to come from either a corruption of the data or from the inadequacy of the point kinetic equations to interpret the measurements in the Minerve driven system. (authors)
This paper present the measurements of VENUS-F kinetic parameters using the Rossi-Alpha methods. The VENUS-F reactor is a zero-power reactor based in Mol, Belgium at SCK-CEN where the fuel is made of metallic enriched uranium with pure lead in order to simulate the behavior of lead fast reactor. The reactor can be operated under critical when it is coupled with GENEPI-3C. At the beginning of 2014, a measurement campaign was performed in order to estimate the kinetics parameters. In this paper, two measurements are analyzed at two different powers (approximately 2 W and 30 W) with 7 different fission chambers (with a 235-U deposit that varies from 1 g to 10 mg). All the correlation functions needed for the Rossi-Alpha method have been built for each possible set of two detectors in each configuration and values obtained from those functions for the effective delayed neutron fraction are then compared. The absolute necessity to operate at very low power is presented. The final value for the effective delayed neutron fraction is finally estimated to be 730 pcm ± 11 pcm and the prompt neutron generation time is estimated to be equal to 0,041 μseconds ± 0.04 μsec. (authors)
Fallot, M.; Giot, L.; Guadilla-Gomez, V.; Le Meur, L.; Porta, A.; Algora, A.; Tain, J. -L.; Briz, J. A.; Agramunt, J.; Aysto, J.; Cormon, S.; Cucoanes, A.; Eronen, T.; Fraile, L. M.; Ganogliu, E.; Gelletly, W.; Gorelov, D.; Hakala, J.; Jokinen, A.; Jordan, M. D.; Kankainen, A.; Kolhinen, V. S.; Koponen, J.; Lebois, M.; Martinez, T.; Monserrate, M.; Montaner-Piza, A.; Moore, I.; Nacher, E.; Orrigo, S. E. A.; Penttila, H.; Pohjalainen, I.; Reinikainen, J.; Reponen, M.; Rinta-Antila, S.; Rytkonen, K.; Rubio, B.; Shiba, T.; Sonnenschein, V.; Valencia, E.; Vedia, V.; Voss, A.; Weber, C.; Wilson, J. N.; Zakari-Issoufou, A. -A.
Not provided.
Accelerator-driven System (ADS), which couples a subcritical core with a spallation neutron source, is proposed as a nuclear transmutation technology to reduce the radioactive half-life of high-level waste. To maintain a safe operation in ADS, the core should be kept in subcritical state. Thus, the subcritical state of the core must be quantified through measurement of subcriticality, which is a quantitative margin from critical state. The area ratio method, or the Sjoestrand method, is one of the subcriticality measurement techniques applicable to the ADS. In this method, the absolute value of subcriticality can be obtained by analyzing the temporal variation of neutron density in the core due to the periodic injection of neutron pulses. In practice, the value of subcriticality is measured by the temporal variation of neutron count rate detected by a detector in the core. Time integrals of count rates due to prompt and delayed neutrons A{sub p} and A{sub d}, are measured. Then, the ratio of A{sub p} to A{sub d}, which is called as the area ratio, yields negative reactivity -ρ, i.e. subcriticality, in dollar units: A{sub p}/A{sub d} ≅ -ρ/β{sub eff'} (1) where β{sub eff} is the effective delayed neutron fraction. Equation (1) represents the basic idea of the Sjoestrand method. Note, however, that Eq. (1) is approximately derived using the point kinetics model. In an actual subcritical system, the measured area ratio is not necessarily equal to the exact value of subcriticality in dollar units, due distortion by spatial higher-order modes. Hence, in the actual measurement, this spatial effect is corrected by a spatial correction factor such as the Bell and Glasstone correction factor (the Bell factor), or by extraction of the fundamental mode (so-called the extrapolated area ratio method). In addition, there is an effect due to the neutron detector materials (e.g. {sup 3}He(n,p) and {sup 235}U(n,f)). These effects must be considered in the correction of the measured area ratio. In this study, we focused on the uncertainty of Bell factor. The Bell factor f is defined by the ratio of the area ratio to the subcriticality as follows: f ≡ -[ρ/β{sub eff}]/[A{sub p}/A{sub d}] (2) The Bell factor f can be evaluated by a core analysis. By multiplying the measured area ratio by the Bell factor?, the spatial higher-order mode effect in the area ratio can be corrected. However, the uncertainty of the Bell factor due to uncertainties of cross-section data (covariance data) has not been quantitatively evaluated so far. In this study, we propose a method to quantify the uncertainty of the Bell factor in an actual core analysis. As a feasibility study, the uncertainty quantification is carried out in a simple one-dimensional subcritical core system. (authors)
A new data-driven sampling-based framework was developed for uncertainty quantification (UQ) of the homogenized kinetic parameters calculated by lattice physics codes such as TRITON and Polaris. In this study, extension of the database for the delayed neutron data (DND) is performed by exploring more delayed neutron experiments and adding additional isotopes/actinides to the data libraries. Afterwards, the framework is utilized to obtain a deeper knowledge of the kinetic parameters’ sensitivity and uncertainty. The kinetic parameters include precursor-group-wise delayed neutron fraction (DNF) and decay constant. Input uncertainties include nuclear data (i.e., cross-sections) and DND (i.e., precursor group parameters and fractional delayed neutron yield). It is found that kinetic parameters, especially DNFs, have large uncertainties. The DNF uncertainty is driven by the cross-section uncertainties for LWR designs, while decay constant uncertainty is dominated by the DND uncertainties. The usage of correlated U-235 thermal DND in the UQ process significantly reduces the DND uncertainty contribution on the kinetic parameters. Large void fraction and presence of neutron absorber (e.g., control rod) increase the DNF uncertainty due to the hardening of neutron spectrum. High correlation between the DNF groups ( β 1 , . . , β 6 ) is observed, while the decay constant groups ( λ 1 , . . , λ 6 ) show weak correlation to each other and also to DNF groups. The DNF uncertainties of the dominant precursor group 4 for PWR, BWR, and VVER are about 7.5%, 9.4%, and 7.6%, respectively. The DNF uncertainty grows to larger values after fuel burnup. Kinetic parameters’ values and uncertainties provided here can be efficiently used in subsequent core calculations, point reactor kinetics, and other applications.
A lot of theoretical and experimental studies devoted to the effect of external electromagnetic fields and ionization on the beta-decay probability have been published in the past years. The possibility of using this physical effect as the main reactor-regulation mechanism is investigated in this study. A set of equations allowing the operation of a nuclear reactor to be described when the probability for the beta decay of precursors of delayed neutrons and, hence, the fraction of delayed neutrons are functions of time is written and investigated. It is shown that, if the fraction of the delayed neutrons does not change, the proposed set of equations coincides with the generally known one. As follows from the analysis of the solutions to the new set of equations, the proposed reactor-regulation method does not allow reactor runaway driven by prompt neutrons even theoretically. The application of the proposed control method to a circulating-fuel liquid-type reactor is briefly considered.
An algorithm for calculation of the neutron importance function and the delayed neutron effective fraction by the Monte Carlo method implemented in the KIR program is presented. The results of calculation of the delayed neutron effective fraction in some critical experiments are given in comparison with the experimental results.
The delayed neutron fraction and prompt neutron lifetime have been calculated at different times in the fuel cycle for the NBSR when fueled with both high-enriched uranium (HEU) and low-enriched uranium (LEU) fuel. The best-estimate values for both the delayed neutron fraction and the prompt neutron lifetime are the result of calculations using MCNP5-1.60 with the most recent ENDFB-VII evaluations. The best-estimate values for the total delayed neutron fraction from fission products are 0.00665 and 0.00661 for the HEU fueled core at startup and end-of-cycle, respectively. For the LEU fuel the best estimate values are 0.00650 and 0.00648 at startup and end-of-cycle, respectively. The present recommendations for the delayed neutron fractions from fission products are smaller than the value reported previously of 0.00726 for the HEU fuel. The best-estimate values for the contribution from photoneutrons will remain as 0.000316, independent of the fuel or time in the cycle. The values of the prompt neutron lifetime as calculated with MCNP5-1.60 are compared to values calculated with two other independent methods and the results are in reasonable agreement with each other. The recommended, conservative values of the neutron lifetime for the HEU fuel are 650 {micro}s and 750 {micro}s for the startup and end-of-cycle conditions, respectively. For LEU fuel the recommended, conservative values are 600 {micro}s and 700 {micro}s for the startup and end-of-cycle conditions, respectively. In all three calculations, the prompt neutron lifetime was determined to be longer for the end-of-cycle equilibrium condition when compared to the startup condition. The results of the three analyses were in agreement that the LEU fuel will exhibit a shorter prompt neutron lifetime when compared to the HEU fuel.
A pile noise measurement campaign has been conducted by the CEA in the VENUS-F reactor (SCK-CEN, Mol Belgium) in April 2011 in the reference critical configuration of the GUINEVERE experimental program. The experimental setup made it possible to estimate the core kinetic parameters: the prompt neutron decay constant, the delayed neutron fraction and the generation time. A precise assessment of these constants is of prime importance. In particular, the effective delayed neutron fraction is used to normalize and compare calculated reactivities of different subcritical configurations, obtained by modifying either the core layout or the control rods position, with experimental ones deduced from the analysis of measurements. This paper presents results obtained with a CEA-developed time stamping acquisition system. Data were analyzed using Rossi-α and Feynman-α methods. Results were normalized to reactor power using a calibrated fission chamber with a deposit of Np-237. Calculated factors were necessary to the analysis: the Diven factor was computed by the ENEA (Italy) and the power calibration factor by the CNRS/IN2P3/LPC Caen. Results deduced with both methods are consistent with respect to calculated quantities. Recommended values are given by the Rossi-α estimator, that was found to be the most robust. The neutron generation time was found equal to 0.438 ± 0.009 μs and the effective delayed neutron fraction is 765 ± 8 pcm. Discrepancies with the calculated value (722 pcm, calculation from ENEA) are satisfactory: -5.6% for the Rossi-α estimate and -2.7% for the Feynman-α estimate. (authors)
A research version of the Monte Carlo software package MCNP6 is modified to incorporate advection and diffusion of delayed neutron precursors, resulting in the emission of delayed neutrons at locations different from the original fission sites. Results of two test problems, a pipe carrying flowing fissile solution and a sphere of fissile solution with precursor diffusion, show that the fission product mobility tends to perturb the fundamental mode, has a negative reactivity effect, and, perhaps most importantly, causes a decrease in the effective delayed neutron fraction. (authors)
Recent releases of three major world nuclear reaction data libraries, ENDF/B-VII.1, JENDL-4.0, and JEFF-3.1.1, have been tested extensively using benchmark calculations. The calculations were performed with the latest release of the continuous energy Monte Carlo neutronics code MCNP, i.e. MCNP6. Three types of benchmarks were used, viz. criticality safety benchmarks, (fusion) shielding benchmarks, and reference systems for which the effective delayed neutron fraction is reported. For criticality safety, more than 2000 benchmarks from the International Handbook of Criticality Safety Benchmark Experiments were used. Benchmarks from all categories were used, ranging from low-enriched uranium, compound fuel, thermal spectrum ones (LEU-COMP-THERM), to mixed uranium-plutonium, metallic fuel, fast spectrum ones (MIX-MET-FAST). For fusion shielding many benchmarks were based on IAEA specifications for the Oktavian experiments (for Al, Co, Cr, Cu, LiF, Mn, Mo, Si, Ti, W, Zr), Fusion Neutronics Source in Japan (for Be, C, N, O, Fe, Pb), and Pulsed Sphere experiments at Lawrence Livermore National Laboratory (for {sup 6}Li, {sup 7}Li, Be, C, N, O, Mg, Al, Ti, Fe, Pb, D2O, H2O, concrete, polyethylene and teflon). The new functionality in MCNP6 to calculate the effective delayed neutron fraction was tested by comparison with more than thirty measurements in widely varying systems. Among these were measurements in the Tank Critical Assembly (TCA in Japan) and IPEN/MB-01 (Brazil), both with a thermal spectrum, two cores in Masurca (France) and three cores in the Fast Critical Assembly (FCA, Japan), all with fast spectra. The performance of the three libraries, in combination with MCNP6, is shown to be good. The results for the LEU-COMP-THERM category are on average very close to the benchmark value. Also for most other categories the results are satisfactory. Deviations from the benchmark values do occur in certain benchmark series, or in isolated cases within benchmark series. Such instances can often be related to nuclear data for specific non-fissile elements, such as C, Fe, or Gd. Indications are that the intermediate and mixed spectrum cases are less well described. The results for the shielding benchmarks are generally good, with very similar results for the three libraries in the majority of cases. Nevertheless there are, in certain cases, strong deviations between calculated and benchmark values, such as for Co and Mg. Also, the results show discrepancies at certain energies or angles for e.g. C, N, O, Mo, and W. The functionality of MCNP6 to calculate the effective delayed neutron fraction yields very good results for all three libraries.
In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared with the GODIVA I experiments. Part of the experimental series was the measurement of the delayed neutron fraction, ßeff, using time correlation measurements and using the central void reactivity measurement. The time correlations measurements were rejected by the experimenter. The measurements using the central void reactivity measurement yielded a ßeff value of 0.00657, which agrees well with the value measured with GODIVA I (0.0066). This measurement is evaluated, found to be acceptable, and discussed in extensive detail in “ORSphere: Physics Measurements for Bare, HEU(93.2) Metal Sphere". In order to determine the delayed neutron fraction using the central void reactivity delayed neutron parameters must be used. The experimenter utilized the delayed neutron parameters set forth by Keepin, Wimment, and Zeigler. If the derivation of the ßeff is repeated with different delayed neutron parameters from various modern nuclear data sets the resulting values vary greatly from the expected results.
MINERVE is a two-zone pool type zero power reactor operated by CEA (Cadarache, France). Kinetic parameters of the core (prompt neutron decay constant, delayed neutron fraction, generation time) have been recently measured using various pile noise experimental techniques, namely Feynman-α, Rossi-α and Cohn-α. Results are discussed and compared to each other's. The measurement campaign has been conducted in the framework of a tri-partite collaboration between CEA, SCK.CEN and PSI. Results presented in this paper were obtained thanks to a time-stamping acquisition system developed by CEA. PSI performed simultaneous measurements which are presented in a companion paper. Signals come from two high efficiency fission chambers located in the graphite reflector next to the core driver zone. Experiments were conducted at critical state with a reactor power of 0.2 W. The core integral fission rate is obtained from a calibrated miniature fission chamber located at the center of the core. Other results obtained in two sub-critical configurations will be presented elsewhere. Best estimate delayed neutron fraction comes from the Cohn-α method: 747 ± 15 pcm (1σ). In this case, the prompt decay constant is 79 ± 0.5 s{sup -1} and the generation time is 94.5 ± 0.7 μs. Other methods give consistent results within the confidence intervals. Experimental results are compared to calculated values obtained from a full 3D core modeling with the CEA-developed Monte Carlo code TRIPOLI4.9 associated with its continuous energy JEFF3.1.1-based library. A very good agreement is observed for the calculated delayed neutron fraction (748.7 ± 0.4 pcm at 1σ), that is a difference of -0.3% with the experiment. On the contrary, a 10% discrepancy is observed for the calculated generation time (104.4 ± 0.1 μs at 1σ). (authors)