Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Unveiling the gamma-ray source count distribution below the Fermi detection limit with photon statistics

The source-count distribution as a function of their flux, dN/dS, is one of the main quantities characterizing gamma-ray source populations. We employ statistical properties of the Fermi Large Area Telescope (LAT) photon counts map to measure the composition of the extragalactic gamma-ray sky at high latitudes (|b|⩾30°) between 1 and 10 GeV. We present a new method, generalizing the use of standard pixel-count statistics, to decompose the total observed gamma-ray emission into (a) point-source contributions, (b) the Galactic foreground contribution, and (c) a truly diffuse isotropic background contribution. Using the 6 yr Fermi-LAT data set (P7REP), we show that the dN/dS distribution in the regime of so far undetected point sources can be consistently described with a power law with an index between 1.9 and 2.0. We measure dN/dS down to an integral flux of ∼2×10{sup −11} cm{sup −2} s{sup −1}, improving beyond the 3FGL catalog detection limit by about one order of magnitude. The overall dN/dS distribution is consistent with a broken power law, with a break at 2.1{sub −1.3}{sup +1.0}×10{sup −8} cm{sup −2} s{sup −1}. The power-law index n{sub 1}=3.1{sub −0.5}{sup +0.7} for bright sources above the break hardens to n{sub 2}=1.97±0.03 for fainter sources below the break. A possible second break of the dN/dS distribution is constrained to be at fluxes below 6.4×10{sup −11} cm{sup −2} s{sup −1} at 95% confidence level. The high-latitude gamma-ray sky between 1 and 10 GeV is shown to be composed of ∼25% point sources, ∼69.3% diffuse Galactic foreground emission, and ∼6% isotropic diffuse background.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Shot noise limited detection of OH using the technique of laser induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Shot noise limited detection of OH using the technique of laser-induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Detection limits for actinides in a monochromatic, wavelength-dispersive x-ray fluorescence instrument

Recent developments in x-ray optics have made it possible to examine the L x-rays of actinides using doubly-curved crystals in a bench-top device. A doubly-curved crystal (DCC) acts as a focusing monochromatic filter for polychromatic x-rays. A Monochromatic, Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) instrument that uses DCCs to measure Cm and Pu in reprocessing plant liquors was proposed in 2007 by the authors at Los Alamos National Laboratory. A prototype design of this MWDXRF instrument was developed in collaboration with X-ray Optical Systems Inc. (XOS), of East Greenbush, New York. In the MWDXRF instrument, x-rays from a Rhodium-anode x-ray tube are passed through a primary DCC to produce a monochromatic beam of 20.2-keV photons. This beam is focused on a specimen that may contain actinides. The 20.2-keV interrogating beam is just above the L3 edge of Californium; each actinide (with Z = 90 to 98) present in the specimen emits characteristic L x-rays as the result of L3-shell vacancies. In the LANL-XOS prototype MWDXRf, these x-rays enter a secondary DCC optic that preferentially passes 14.961-keV photons, corresponding to the L-alpha-1 x-ray peak of Curium. In the present stage of experimentation, Curium-bearing specimens have not been analyzed with the prototype MWDXRF instrument. Surrogate materials for Curium include Rubidium, which has a K-beta-l x-ray at 14.961 keV, and Yttrium, which has a K-alpha-1 x-ray at 14.958 keV. In this paper, the lower limit of detection for Curium in the LANL-XOS prototype MWDXRF instrument is estimated. The basis for this estimate is described, including a description of computational models and benchmarking techniques used. Detection limits for other actinides are considered, as well as future safeguards applications for MWDXRF instrumentation.

36 MATERIALS SCIENCE↗

The Impact of Below Detection Limit Samples in (NPP) Decommissioning Residual Risk Assessment - 17033

There are some technical problems with finalizing regulations and standards that address nuclear power plant (NPP) decommissioning site soil analyses for license termination. It is difficult to know how to best include detection limit observations from site soil analysis, because typical soil collection data is reported above, at, and below the detection limit. In addition, multiple detection limits are required to adequately estimate the soil radionuclide concentrations. In the literature, researchers analyzing environmental data refer to below the detection limit observations as 'left-censored data'. Left-censored data are less than the detection limit of the instrument(s) that made the measurements. Conventional approaches to managing left-censored data either ignore or simply replace the detection limits with zero, a fraction of the detection limit, or the detection limit itself. However, these approaches are statistically biased and limited in their usefulness. The Kaplan-Meier method, robust regression on order statistics method, and maximum likelihood estimation method are proposed to estimate the left-censored data more precisely. The proposed methods are applied to data from a Monazite powder manufacturing plant and the Colorado School of Mines Research Institute. Summary statistics such as the sample mean, sample standard deviation, sample percentiles are calculated from each data set and are used in risk and volume estimation calculations. Previous environmental analyses, such as the exposure assessment, recognize the uncertainty issue that is addressed in this research using the Latin hypercube sampling approach. Next, probabilistic distributions of the input parameters are developed for the uncertainty analyses. Finally, a framework methodology depicting the decision-making process in the proposed method is presented. The framework defines the critical steps, the amount of radioactivity, types of distributions, censoring percentage, sample size, and number of detection limits; it also allows the user to select the appropriate approach based on their site-specific data and analyses. The goal of this research is to develop a more precise risk assessment, estimate of the volume of soil removal, examine potential cost savings. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

F and Cl detection limits in secondary ion mass spectrometry measurements of Si and SiO{sub 2} samples

Usually, F and Cl negative secondary ion currents forming background signals determine detection limits for these elements in secondary ion mass spectrometry (SIMS) measurements. Technique involving changing the primary-ion current was used to determine that the ''memory effect'' is the main source of the background signal for these elements. It is shown that energy distributions of F and Cl ions forming background signals are distinctly narrower than energy distributions of these ions reflecting element bulk concentration in a Si wafer. Using this fact, the F and Cl detection limits in Si were improved by energy filtering of secondary ions. For experimental conditions used, the filtering of the secondary ion energy in a region around 60-70 eV improves the F and Cl detection limits by a factor of more than 6. The effect of an electron beam used for charge neutralization of insulator samples in a negative SIMS mode on the F and Cl detection limits was also investigated. It is shown that the simultaneous use of the primary ion and electron beams causes a synergistic increase of the background signals. It was determined that both F and Cl detection limits for the SiO{sub 2} sample are almost the same as for the Si sample when the electron and ion beams are applied simultaneously. The possible mechanism of this effect is discussed.

36 MATERIALS SCIENCE↗

Sample-morphology effects on x-ray photoelectron peak intensities. II. Estimation of detection limits for thin-film materials

The authors show that the National Institute of Standards and Technology database for the simulation of electron spectra for surface analysis (SESSA) can be used to determine detection limits for thin-film materials such as a thin film on a substrate or buried at varying depths in another material for common x-ray photoelectron spectroscopy (XPS) measurement conditions. Illustrative simulations were made for a W film on or in a Ru matrix and for a Ru film on or in a W matrix. In the former case, the thickness of a W film at a given depth in the Ru matrix was varied so that the intensity of the W 4d{sub 5/2} peak was essentially the same as that for a homogeneous RuW{sub 0.001} alloy. Similarly, the thickness of a Ru film at a selected depth in the W matrix was varied so that the intensity of the Ru 3p{sub 3/2} peak matched that from a homogeneous WRu{sub 0.01} alloy. These film thicknesses correspond to the detection limits of each minor component for measurement conditions where the detection limits for a homogeneous sample varied between 0.1 at. % (for the RuW{sub 0.001} alloy) and 1 at. % (for the WRu{sub 0.01} alloy). SESSA can be similarly used to convert estimates of XPS detection limits for a minor species in a homogeneous solid to the corresponding XPS detection limits for that species as a thin film on or buried in the chosen solid.

36 MATERIALS SCIENCE↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

Detection Limits and Near‐Field Ground Motions of Fast and Slow Earthquakes

Abstract We investigate theoretical limits to detection of fast and slow seismic events, and spatial variations of ground motion expected from M 6 earthquakes at short epicentral distances. The analyses are based on synthetic velocity seismograms calculated with the discrete wavenumber method assuming seismic velocities and attenuation properties of the crust in Southern California. The examined source properties include different magnitudes ( M −1.0 to M 6.0), static stress drops (0.1–10 MPa), and slow and fast ruptures (0.1–0.9 of shear wave velocity). For the M 6 events we also consider variations in rise times producing crack‐ and pulse‐type events and different rupture directivities. Slow events produce ground motion with considerably lower amplitude than corresponding regular fast earthquakes with the same magnitude, and hence are significantly more difficult to detect. The static stress drop and slip rise time also affect the maximum radiated seismic motion, and hence event detectability. Apart from geometrical factors, the saturation and depletion of seismic ground motion at short epicentral distances stem from radiation pattern, earthquake size (magnitude, stress drop), and rupture directivity. The rupture velocity, rise time, and directivity affect significantly the spatial pattern of the ground motions. The results can help optimizing detection of slow and fast small earthquakes and understand the spatial distribution of ground motion generated by large events.

58 GEOSCIENCES↗

SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

60 APPLIED LIFE SCIENCES↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced detection limits for radiokrypton analysis

In this paper, we present a method for improving detection limits of Atom Trap Trace Analysis for the krypton radioisotopes 85 Kr and 81 Kr. For the case of 85 Kr this work demonstrates that systematic use of isotopically depleted gas for calibration and extended conditioning of the instrument results in a detection limit of 900 85 Kr atoms per 11 μl of Kr gas, equivalent to a 85 Kr/Kr isotopic abundance of 3 x 10 -15 . This improvement of roughly two orders of magnitude over previously reported limits will help to expand the reach of radiokrypton dating towards longer age ranges where most of the radioisotopes have decayed. Additionally, the method offers an opportunity to investigate radiokrypton production via spontaneous fission within naturally occurring minerals to understand potential underground production of these isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impacts of active satellite sensors' low-level cloud detection limitations on cloud radiative forcing in the Arctic

Previous studies revealed that satellites sensors with the best detection capability identify 25 %–40 % and 0 %–25 % fewer clouds below 0.5 and between 0.5–1.0 km, respectively, over the Arctic. Quantifying the impacts of cloud detection limitations on the radiation flux are critical especially over the Arctic Ocean considering the dramatic changes in Arctic sea ice. In this study, the proxies of the space-based radar, CloudSat, and lidar, CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations), cloud masks are derived based on simulated radar reflectivity with QuickBeam and cloud optical thickness using retrieved cloud properties from surface-based radar and lidar during the Surface Heat Budget of the Arctic Ocean (SHEBA) experiment. Limitations in low-level cloud detection by the space-based active sensors, and the impact of these limitations on the radiation fluxes at the surface and the top of the atmosphere (TOA), are estimated with radiative transfer model Streamer. The results show that the combined CloudSat and CALIPSO product generally detects all clouds above 1 km, while detecting 25 % (9 %) fewer in absolute values below 600 m (600 m to 1 km) than surface observations. These detection limitations lead to uncertainties in the monthly mean cloud radiative forcing (CRF), with maximum absolute monthly mean values of 2.5 and 3.4 Wm –2 at the surface and TOA, respectively. Cloud information from only CALIPSO or CloudSat lead to larger cloud detection differences compared to the surface observations and larger CRF uncertainties with absolute monthly means larger than 10.0 Wm –2 at the surface and TOA. The uncertainties for individual cases are larger – up to 30 Wm –2 . These uncertainties need to be considered when radiation flux products from CloudSat and CALIPSO are used in climate and weather studies.

54 ENVIRONMENTAL SCIENCES↗

Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

Achilles, C. N.↗

Experimental Study of the Detection Limit in Dual-Gate Biosensors Using Ultrathin Silicon Transistors

Dual-gate field-effect biosensors (bioFETs) with asymmetric gate capacitances were shown to surpass the Nernst limit of 59 mV/pH. However, previous studies have conflicting findings on the effect of the capacitive amplification scheme on the sensor detection limit, which is inversely proportional to the signal-to-noise ratio (SNR). In this paper, we present a systematic experimental investigation of the SNR using ultrathin silicon transistors. Our sensors operate at low voltage and feature asymmetric front and back oxide capacitances with asymmetry factors of 1.4 and 2.3. We demonstrate that in the dual-gate configuration, the response of our bioFETs to the pH change increases proportional to the asymmetry factor and indeed exceeds the Nernst limit. Further, our results reveal that the noise amplitude also increases in proportion to the asymmetry factor. We establish that the commensurate increase of the noise amplitude originates from the intrinsic low-frequency characteristic of the sensor noise, dominated by number fluctuation. Finally, these findings suggest that this capacitive signal amplification scheme does not improve the intrinsic detection limit of the dual-gate biosensors.

42 ENGINEERING↗

Detectability limit and uncertainty considerations for laser induced fluorescence spectroscopy in flames

Laser induced fluorescence spectroscopy of flames is discussed, and derived uncertainty relations are used to calculate detectability limits due to statistical errors. Interferences due to Rayleigh scattering from molecules as well as Mie scattering and incandescence from particles have been examined for their effect on detectability limits. Fluorescence trapping is studied, and some methods for reducing the effect are considered. Fluorescence trapping places an upper limit on the number density of the fluorescing species that can be measured without signal loss.

Daily, J. W.↗