Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Image Correlation (DIC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Introduction to Digital Image Correlation (DIC) with annotated bibliography

Digital Image Correlation (DIC) is “a non-contact means of measuring motion and deformation using digital images of the object of interest”, capable of full-field measurements over large areas. Getting started in DIC can be difficult, since there are many different techniques, and the body of literature on DIC is extensive. IEEE Xplore alone lists nearly 11,000 references, including magazines, conference proceedings, journal articles, books, etc. A Google search returns around 145 million results. The intent of this annotated bibliography is to provide an entry point for beginners and to collect references that may be useful to more advanced practitioners.

42 ENGINEERING↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Split Disk Mechanical Testing Studies with a Digital Image Correlator

Nuclear graphite plays a pivotal role in the advanced reactor program. Consequently, developing a viable method to measure and evaluate small samples is essential. The Digital Image Correlation (DIC) technique allows for the examination of much smaller components in real-time applications, particularly concerning reactor capsule design and placement within the reactor. These samples become crucial for understanding the behavior of nuclear graphite before and after radiation exposure. They serve as a means to analyze changes and effectively measure the mechanical strength properties, which may or may not alter following irradiation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Intern Poster

Digital Image Correlation (DIC) is an optical technique that combines image registration and tracking methods for accurate two-dimensional and three-dimensional changes in images. DIC software can be used to track the contour, deformation, and strain of a sample. In the Advanced Test Reactor (ATR) at INL (Idaho National Laboratory) there exists a small working window of samples that can become irradiated. Hundreds of graphite disks called piggybacks have undergone this irradiation as part of the Advanced Reactor Technologies (ART) program. After irradiation, it is desirable to understand the change in tensile strength as a function of dose. Due to the limited space in the ATR, typical dog bone tensile tests reduce the number of graphite samples from hundreds to tens. However, there does exist an ASTM standard, D8289, which uses disc compression of graphite to estimate the tensile strength of the specimen with the Brazilian Disk test fixture. While only used as an estimate, which is typically off by a third, it is the purpose of this study to identify how to amend D8289 to remove the word "estimate" with the help of DIC.

36 MATERIALS SCIENCE↗

Experimental Examination of Additively Manufactured Patterns on Structural Nuclear Materials for Digital Image Correlation Strain Measurements

Abstract Background There are a limited number of commercially available sensors for monitoring the deformation of materials in-situ during harsh environment applications, such as those found in the nuclear and aerospace industries. Such sensing devices, including weldable strain gauges, extensometers, and linear variable differential transformers, can be destructive to material surfaces being investigated and typically require relatively large surface areas to attach (> 10 mm in length). Digital image correlation (DIC) is a viable, non-contact alternative to in-situ strain deformation. However, it often requires implementing artificial patterns using splattering techniques, which are difficult to reproduce. Objective Additive manufacturing capabilities offer consistent patterns using programmable fabrication methods. Methods In this work, a variety of small-scale periodic patterns with different geometries were printed directly on structural nuclear materials (i.e., stainless steel and aluminum tensile specimens) using an aerosol jet printer (AJP). Unlike other additive manufacturing techniques, AJP offers the advantage of materials selection. DIC was used to track and correlate strain to alternative measurement methods during cyclic loading, and tensile tests (up to 1100 µɛ) at room temperature. Results The results confirmed AJP has better control of pattern parameters for small fields of view and facilitate the ability of DIC algorithms to adequately process patterns with periodicity. More specifically, the printed 100 μm spaced dot and 150 μm spaced line patterns provided accurate measurements with a maximum error of less than 2% and 4% on aluminum samples when compared to an extensometer and commercially available strain gauges. Conclusion Our results highlight a new pattern fabrication technique that is form factor friendly for digital image correlation in nuclear applications.

Novich, K. A. (ORCID:0000000204466022)↗

Enhancing Post-Irradiation Examination (PIE) Efficiency with High-Throughput Experiments

Nuclear materials testing is essential for understanding changes in reactor environments, but traditional methods are costly and time-consuming. High-Throughput Experimentation (HTE) enables rapid screening and optimization of material properties by significantly increasing the number of specimens in the experiment. In this work, HTE methods were employed to irradiate novel materials at the Advanced Test Reactor (ATR) at Idaho National Laboratory. A total of 367 sub-sized tensile specimens were irradiated using the standard capsule design. To facilitate HTE, automated systems such as the Automated Mechanical Testing System were implemented for mechanical testing within hot cell environments, thereby reducing the need for manual interaction with hot cell manipulators and significantly lowering both the cost and duration of experiments. Digital image correlation (DIC) was used to measure displacement during mechanical testing, providing precise, non-contact measurement capabilities. The methodologies developed in this research will support the advancement of HTE techniques for future nuclear materials testing experiments at ATR. This approach allows for more efficient and cost-effective evaluation of new materials, ultimately leading to improved reactor performance, enhanced safety, and extended longevity within the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

Effect of Sample Thickness on the Tensile Strength of Small Graphite Discs

This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.

36 MATERIALS SCIENCE↗

Control of machining-induced residual stress via tool geometry and process parameter modification

Distortion generated in machined, monolithic, thin-walled aerospace components due to residual stresses leads to significant material and economic waste in the manufacturing industry. Inherent residual stress (IRS) present in stock materials combines with machining-induced residual stress (MIRS) to influence the final machined part distortion. It is hypothesized that MIRS can be controlled, based on the part geometry, through deliberate cutting tool geometry and process parameter modifications to negate the effect of IRS on distortion, consequently resulting in distortion-free parts. A finite element (FE) orthogonal cutting model is developed to study how tool geometry and process parameters influence machining-induced residual stress (MIRS). Orthogonal cutting experiments are performed on Al 7075-T651 samples to measure cutting forces and MIRS. A cutting force dynamometer is used to measure forces during cutting and a novel digital image correlation (DIC) based hole drilling technique is employed to measure the near-surface residual stress (RS) in the cut samples. These data are subsequently utilized to validate the FE prediction model. Various cases of cutting simulations involving different depths of cut, tool tip radii, and rake angles are performed to study their effects on RS. Similar to prior literature, increasing the depth of cut, tool tip radius, or rake angle is found to promote the formation of near-surface tensile stresses. The competing effects of material plowing and temperature are shown to determine the type of RS at the end of the cut. Moreover, a window of variation of RS (up to ± 400 MPa) is estimated within the given range of conditions, allowing for the control of MIRS through tool and process modification.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD↗

Impact of Backing Plate and Thermal Boundary Conditions for High-Speed Friction Stir Welding of 25-mm Thick Aluminum Alloy 7175-T79

Here this study demonstrates high-speed (150 mm/min) single pass friction stir butt joining of 25 mm thick aluminum alloy 7175-T79. To understand the impact of quenching and cooling rate on process responses, joint strength, and grain size distributions across the weld thickness, we performed a series of friction stir welding (FSW) trials in air and with a trailing water spray using steel and composite backing plates (BP). Welds made in air and trailing water spray exhibit significantly different hardness distributions across the nugget, heat affected zone (HAZ), and HAZ minimum hardness as evidenced by detailed microhardness mapping. The effect of trailing water spray (TWS) on joint efficiency overshadows the influence of BP composition due to the vastly different contribution to quenching. TWS also resulted in a multifaceted effect on FSW such as lowering processing temperature, increasing X and Z forces while lowering Y force, and narrow heat affecting zone. Finally, digital image correlation (DIC)-based fracture mode analysis and grain size measurements correlate with the hardness distribution.

42 ENGINEERING↗

A Method for Dynamic Kolsky Bar Compression at High Temperatures: Application to Ti-6Al-4V

Abstract An experimental apparatus for measuring the dynamic behavior of materials subjected to strain rates on the order of 10 $$^3$$ 3 s $$^{-1}$$ - 1 and temperatures up to 800°C with a unique triple actuation system is developed in this work. This system is based on the traditional Kolsky (or split-Hopkinson pressure) bar design, with the addition of an external furnace used to heat the specimen to the desired temperature. A synchronized triple pneumatic actuation system is used to control the motion and timing of the the sample, incident, and transmitted bars. The cold contact time (CCT), or the time during which the heated sample is in contact with the room temperature bars before compression, is measured experimentally and carefully controlled to minimize the development of a temperature gradient across the sample and avoid heating of the bars. Experiments are performed in conjunction with ultra high speed imaging and 2D digital image correlation (DIC), as well as high speed thermal imaging. To verify the viability of the proposed system, experiments were conducted on Ti-6Al-4V (wt.%) at temperatures from 25°C up to and 800°C at an average strain rate of approximately 1200 s $$^{-1}$$ - 1 .

36 MATERIALS SCIENCE↗