Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Digital Imaging

Digital Imaging is the computer processed numerical representation of physical images. Enhancement of images results in easier interpretation. Quantitative digital image analysis by Perceptive Scientific Instruments, locates objects within an image and measures them to extract quantitative information. Applications are CAT scanners, radiography, microscopy in medicine as well as various industrial and manufacturing uses. The PSICOM 327 performs all digital image analysis functions. It is based on Jet Propulsion Laboratory technology, is accurate and cost efficient.

Source record↗

Algorithm For Enlargement Of Digitized Images

Digital Image Enlarging Balanced Reconstruction Algorithm (DIEBRA) enlarges digitized image composed of square pixels to make image look more like real scene. Synthesizes enlarged image at greater number of pixels, smoothing out blockiness while providing resolution finer than original pixels and closer to scene. Based on more-realistic treatment of pixels, not as points but as areas representing spatial-resolution elements or fields of view of imaging instrument.

Rhea, William J.↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

Results of precision processing (scene correction) of ERTS-1 images using digital image processing techniques

ERTS-1 MSS and RBV data recorded on computer compatible tapes have been analyzed and processed, and preliminary results have been obtained. No degradation of intensity (radiance) information occurred in implementing the geometric correction. The quality and resolution of the digitally processed images are very good, due primarily to the fact that the number of film generations and conversions is reduced to a minimum. Processing times of digitally processed images are about equivalent to the NDPF electro-optical processor.

Bernstein, R.↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

APQ-102 imaging radar digital image quality study

A modified APQ-102 sidelooking radar collected synthetic aperture radar (SAR) data which was digitized and recorded on wideband magnetic tape. These tapes were then ground processed into computer compatible tapes (CCT's). The CCT's may then be processed into high resolution radar images by software on the CYBER computer.

Griffin, C. R.↗

The use of variograms in remote sensing. I - Scene models and simulated images. II - Real digital images

Theoretical and empirical studies of variograms are presented. The sensitivity of variograms is studied through varyig parameters of scene models both in calculating explicit variograms and in simulating images. It is found that the heights of variograms are related to the proportion of an area covered by objects. It is shown that the range of influence of a variogram is related to the size of the objects in the scene and that the shape of the variogram becomes more rounded as the variance in the size distribution of objects increases. In the second part, empirically calculated variograms from real digital images are used to demonstrate these theoretical findings. These calculated variograms also show the periodicity in ground scenes and reveal anisotropy.

Woodcock, Curtis E.↗

Digital imaging technology assessment: Digital document storage project

An ongoing technical assessment and requirements definition project is examining the potential role of digital imaging technology at NASA's STI facility. The focus is on the basic components of imaging technology in today's marketplace as well as the components anticipated in the near future. Presented is a requirement specification for a prototype project, an initial examination of current image processing at the STI facility, and an initial summary of image processing projects at other sites. Operational imaging systems incorporate scanners, optical storage, high resolution monitors, processing nodes, magnetic storage, jukeboxes, specialized boards, optical character recognition gear, pixel addressable printers, communications, and complex software processes.

Source record↗

Sand Shear Band Thickness Measurements by Digital Imaging Techniques

Digital imaging analysis was used to study localized deformations in granular materials tested under plane strain condition. Two independent techniques were applied and compared. In the first, the digitized optical images of a grid printed on the latex membrane were used to measure the shear band orientation angle and thickness, and were found to be 54.5' and 3.01 mm respectively. The second technique involved introducing an ultra-low viscosity resin into the specimen in preparation for thin- sectioning and microscopic study of the internal fabric. A total of 24 microscopic images obtained from four thin sections were analyzed and void ratio variation was measured. The shear band thickness measurements from images located along the shear band axis (at two locations) were equal to 3.19 mm and 3.29 mm which are very close to the average value obtained from surface analysis. The study was then extended to investigate the effects of sand grain-size and properties, specimen density, and confining pressure on shear band thickness. It was found that the normalized shear band thickness decreases as grain-size and confining pressure increase and as density decreases. Finally, shear band thickness is highly influenced by the specimen dilatancy.

Alshibli, Khalid A.↗

Applications of digital image processing

Digital image processing applied to picture generation, intensity and geometric manipulation, spatial frequency operations and image analysis

Billingsley, F. C.↗

Characterization of coherent structures in a turbulent mixing layer by digital image analysis

Digital image analysis has been applied to a shadowgraph motion picture of a helium nitrogen mixing layer in order to characterize the coherent vortex structures in the flow. Both the primary spanwise coherent vortices and secondary streamwise vortices are considered. Pattern recognition algorithms were designed to take advantage of the more pronounced features of the vortices and of their temporal coherence to isolate them and to measure their characteristics. The resulting data base permits a deterministic description of the evolution of primary and seconary vortices.

Bernal, L. P.↗

Digital image velocimetry

Digital image velocimetry is proposed for the measurement of the instantaneous velocity fields of time dependent flows. This technique improves the flow measurement by eliminating some of the restrictions on existing optical methods (i.e., laser speckle velocimetry and particle image velocimetry). Among these restrictions are the limited dynamic range of the velocity measurement, directional ambiguity of the velocity vector, and the difficulty of a real-time capability. The present technique greatly enhances the dynamic range of the velocity measurement and unequivocally determines the direction of the velocity vector.

Cho, Y.-C.↗

Digital Image Velocimetry

Digital image velocimetry is technique for extracting two-dimensional (in image planes) velocities of objects from multiple photographs or video images of objects. Devised to overcome disadvantages of particle-image velocimetry and laser-speckle velocimetry, both of which involve use of illuminated seed particles to make flows visible. Directions of velocity vectors determined unambiguously, and dynamic range limited only by speed of camera or, equivalently, by speed of stroboscopic illumination.

Cho, Y.-C.↗

Digital image centering. II

Digital image centering algorithms were compared in a test involving microdensitometer raster scans of a refractor parallax series consisting of 22 stars on 26 plates. The highest accuracy in determining stellar image positions was provided by an algorithm which involved fitting of a symmetric Gaussian curve and a flat background to the image marginal density distributions. Algorithms involving transmission marginals instead of density marginals were found to be less accurate. The repeatability and computational efficiency of the digital image centering technique were also studied.

Auer, L. H.↗

Geometric assessment of image quality using digital image registration techniques

Image registration techniques were developed to perform a geometric quality assessment of multispectral and multitemporal image pairs. Based upon LANDSAT tapes, accuracies to a small fraction of a pixel were demonstrated. Because it is insensitive to the choice of registration areas, the technique is well suited to performance in an automatic system. It may be implemented at megapixel-per-second rates using a commercial minicomputer in combination with a special purpose digital preprocessor.

Tisdale, G. E.↗