Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Introduction to Digital Image Correlation (DIC) with annotated bibliography

Digital Image Correlation (DIC) is “a non-contact means of measuring motion and deformation using digital images of the object of interest”, capable of full-field measurements over large areas. Getting started in DIC can be difficult, since there are many different techniques, and the body of literature on DIC is extensive. IEEE Xplore alone lists nearly 11,000 references, including magazines, conference proceedings, journal articles, books, etc. A Google search returns around 145 million results. The intent of this annotated bibliography is to provide an entry point for beginners and to collect references that may be useful to more advanced practitioners.

42 ENGINEERING↗

Super Resolution Digital Image Correlation (SR-DIC): an Alternative to Image Stitching at High Magnifications

Abstract Background High-resolution Digital Image Correlation (DIC) measurements have previously been produced by stitching of neighboring images, which often requires short working distances. Separately, the image processing community has developed super resolution (SR) imaging techniques, which improve resolution by combining multiple overlapping images. Objective This work investigates the novel pairing of super resolution with digital image correlation, as an alternative method to produce high-resolution full-field strain measurements. Methods First, an image reconstruction test is performed, comparing the ability of three previously published SR algorithms to replicate a high-resolution image. Second, an applied translation is compared against DIC measurement using both low- and super-resolution images. Third, a ring sample is mechanically deformed and DIC strain measurements from low- and super-resolution images are compared. Results SR measurements show improvements compared to low-resolution images, although they do not perfectly replicate the high-resolution image. SR-DIC demonstrates reduced error and improved confidence in measuring rigid body translation when compared to low resolution alternatives, and it also shows improvement in spatial resolution for strain measurements of ring deformation. Conclusions Super resolution imaging can be effectively paired with Digital Image Correlation, offering improved spatial resolution, reduced error, and increased measurement confidence.

Hansen, R. S.↗

Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation

Shock compression plate impact experiments conventionally rely on point-wise velocimetry measurements based on laser-based interferometric techniques. This study presents an experimental methodology to measure the free surface full-field particle velocity in shock compression experiments using high-speed imaging and three-dimensional (3D) digital image correlation (DIC). The experimental setup has a temporal resolution of 100 ns with a spatial resolution varying from 90 to 200 μm/pixel. Experiments were conducted under three different plate impact configurations to measure spatially resolved free surface velocity and validate the experimental technique. First, a normal impact experiment was conducted on polycarbonate to measure the macroscopic full-field normal free surface velocity. Second, an isentropic compression experiment on Y-cut quartz–tungsten carbide assembly is performed to measure the particle velocity for experiments involving ramp compression waves. To explore the capability of the technique in multiaxial loading conditions, a pressure shear plate impact experiment was conducted to measure both the normal and transverse free surface velocities under combined normal and shear loading. The velocities measured in the experiments using digital image correlation are validated against previous data obtained from laser interferometry. Numerical simulations were also performed using established material models to compare and validate the experimental velocity profiles for these different impact configurations. The novel ability of the employed experimental setup to measure full-field free surface velocities with high spatial resolutions in shock compression experiments is demonstrated for the first time in this work.

47 OTHER INSTRUMENTATION↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

Digital Image Correlation as an Experimental Modal Analysis Capability

Digital image correlation (DIC) is an established test technique in several fields including quasi-static displacement measurements. Recently there has been growing interest in using DIC to measure structural dynamic response and even extract modal parameters from that information. Although high-speed cameras have become more ubiquitous, there are no commercial end-to-end packages for modal analysis based on image data, particularly when combined with traditional data acquisition systems. As such, the practitioner is left to develop several key data processing capabilities, hardware interface equipment, and testing practices themselves. This work highlights several practical aspects that have been encountered while establishing DIC as a viable modal testing capability in a laboratory environment.

47 OTHER INSTRUMENTATION↗

Validation of finite-element models using full-field experimental data: Levelling finite-element analysis data through a digital image correlation engine

Full-field data from digital image correlation (DIC) provide rich information for finite-element analysis (FEA) validation. However, there are several inherent inconsistencies between FEA and DIC data that must be rectified before meaningful, quantitative comparisons can be made, including strain formulations, coordinate systems, data locations, strain calculation algorithms, spatial resolutions and data filtering. As such, in this paper, we investigate two full-field validation approaches: (1) the direct interpolation approach, which addresses the first three inconsistencies by interpolating the quantity of interest from one mesh to the other, and (2) the proposed DIC-levelling approach, which addresses all six inconsistencies simultaneously by processing the FEA data through a stereo-DIC simulator to ‘level’ the FEA data to the DIC data in a regularisation sense. Synthetic ‘experimental’ DIC data were generated based on a reference FEA of an exemplar test specimen. The direct interpolation approach was applied, and significant strain errorswere computed, even though therewas no model form error, because the filtering effect of theDIC enginewas neglected. In contrast, the levelling approach provided accurate validation results, with no strain error when no model form error was present. Next, model form error was purposefully introduced via a mismatch of boundary conditions. With the direct interpolation approach, the mismatch in boundary conditions was completely obfuscated, while with the levelling approach, it was clearly observed. Finally, the ‘experimental’ DIC datawere purposefully misaligned slightly fromthe FEA data. Both validation techniques suffered from the misalignment, thus motivating continued efforts to develop a robust alignment process. In conclusion, direct interpolation is insufficient, and the proposed levelling approach is required to ensure that the FEA and the DIC data have the same spatial resolution and data filtering. Only after the FEA data have been ‘levelled’ to the DIC data can meaningful, quantitative error maps be computed.

42 ENGINEERING↗

Measurement of Photovoltaic Module Deformation Dynamics During Hail Impact Using Digital Image Correlation

Stereo high-speed video of photovoltaic modules undergoing laboratory hail tests was processed using digital image correlation to determine module surface deformation during and immediately following impact. The purpose of this work was to demonstrate a methodology for characterizing module impact response differences as a function of construction and incident hail parameters. Video capture and digital image analysis were able to capture out-of-plane module deformation to a resolution of ±0.1 mm at 11 kHz on an in-plane grid of 10 × 10 mm over the area of a 1 × 2 m commercial photovoltaic module. With lighting and optical adjustments, the technique was adaptable to arbitrary module designs, including size, backsheet color, and cell interconnection. Furthermore, impacts were observed to produce an initially localized dimple in the glass surface, with peak deflection proportional to the square root of incident energy. Subsequent deformation propagation and dissipation were also captured, along with behavior for instances when the module glass fractured. Natural frequencies of the module were identifiable by analyzing module oscillations postimpact. Limitations of the measurement technique were that the impacting ice ball obscured the data field immediately surrounding the point of contact, and both ice and glass fracture events occurred within 100 μs, which was not resolvable at the chosen frame rate. Increasing the frame rate and visualizing the back surface of the impact could be applied to avoid these issues. Applications for these data include validating computational models for hail impacts, identifying the natural frequencies of a module, and identifying damage initiation mechanisms.

14 SOLAR ENERGY↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

High-Speed X-Ray Stereo Digital Image Correlation in a Shock Tube

X-ray stereo digital image correlation (DIC) measurements were performed at 10 kHz on the internal surface of a jointed structure in a shock tube at a shock Mach number of 1.42 and compared with optical stereo DIC measurements on the outer, visible surface of the structure. The shock tube environment introduces temperature and density gradients in the gas through which the structure was imaged, resulting in spatial and temporal index of refraction variations. These variations cause bias errors in optical DIC measurements due to beam-steering but have minimal influence on x-ray DIC measurements. These results demonstrate the utility of time-resolved x-ray DIC measurements in complicated environments where optical measurements suffer severe errors and/or are precluded by lack of optical access.

42 ENGINEERING↗

Analyzing the Validity of Brazilian Testing Using Digital Image Correlation and Numerical Simulation Techniques

Characterizing the mechanical behavior of rocks plays a crucial role to optimize the fracturing process in unconventional reservoirs. However, due to the intrinsic anisotropy and heterogeneity in unconventional resources, fracture process prediction remains the most significant challenge for sustainable and economic hydrocarbon production. During the deformation tracking under compression, deploying conventional methods (strain gauge, extensometer, etc.) is insufficient to measure the deformation since the physical attachment of the device is restricted to the size of the sample, monitoring limited point-wise deformation, producing difficulties in data retrieval, and a tendency to lose track in failure points, etc. Where conventional methods are limited, the application of digital image correlation (DIC) provides detailed and additional information of strain evolution and fracture patterns under loading. DIC is an image-based optical method that records an object with a camera and monitors the random contrast speckle pattern painted on the facing surface of the specimen. To overcome the existing limitations, this paper presents numerical modeling of Brazilian disc tests under quasi-static conditions to understand the full-field deformation behaviors and finally, it is validated by DIC. As the direct tensile test has limitations in sample preparation and test execution, the Brazilian testing principle is commonly used to evaluate indirectly the tensile strength of rocks. The two-dimensional numerical model was built to predict the stress distribution and full-field deformation on Brazilian disc under compression based on the assumptions of a homogenous, isotropic and linear elastic material. The uniaxial compression test was conducted using the DIC technique to determine the elastic properties of Spider Berea sandstone, which were used as inputs for the simulation model. The model was verified by the analytical solution and compared with the digital image correlation. The numerical simulation results showed that the solutions matched reasonably with the analytical solutions where the maximum deviation of stress distribution was obtained as 14.59%. The strain evolution (normal and shear strains) and displacements along the central horizontal and vertical planes were investigated in three distinguishable percentages of peak loads (20%, 40%, and 90%) to understand the deformation behaviors in rock. The simulation results demonstrated that the strain evolution contours consistently matched with DIC generated contours with a reasonable agreement. The changes in displacement along the central horizontal and vertical planes showed that numerical simulation and DIC generated experimental results were repeatable and matched closely. In terms of validation, Brazilian testing to measure the indirect tensile strength of rocks is still an issue of debate. The numerical model of fracture propagation supported by digital image correlation from this study can be used to explain the fracturing process in the homogeneous material and can be extended to non-homogeneous cases by incorporating heterogeneity, which is essential for rock mechanics field applications.

58 GEOSCIENCES↗

Fiber Orientation Evaluation in Reinforced Composites using Digital Image Correlation

This paper presents an innovative nondestructive evaluation (NDE) approach to evaluate fiber orientation in fiber reinforced composites utilizing digital image correlation (DIC). Fiber orientation is a crucial factor that influences the mechanical and thermal properties of the composite. Conventional methods for fiber orientation evaluation and measurement are either destructive, which are typically laborious. NDE methods such as micro computed tomography are expensive and limited in sample size. In this work, we evaluate two methods of excitation of the composite, namely-quasistatic mechanical loading and thermal cycling. Digital Image Correlation (DIC) has been employed in conjunction for fiber orientation measurements. The DIC system is able to measure the fiber orientation by capturing 19x higher strain in the transverse direction of the reinforced fiber axis during excitation. The larger strain occurs in the transverse direction due to larger elongation in the surrounding polymer matrix than the fiber which resists elongation. This innovative method is within the preliminary stage and has been developed to fill the gap/limitations of other NDE methods.

Spencer, Ryan↗