Theorem-Proving Analysis of Digital Control Logic Interacting with Continuous Dynamics.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The United States (U.S.) nuclear industry, like similar process control industries, has moved toward upgrading its control rooms. The upgraded control rooms typically feature digital control system (DCS) displays embedded in the panels. These displays gather information from the system and represent that information on a single display surface. In this manner, the DCS combines many previously separate analog indicators and controls into a single digital display, whereby the operators can toggle between multiple windows to monitor and control different aspects of the plant. The design of the DCS depends on the function of the system it monitors, but revolves around presenting the information most germane to an operator at any point in time. DCSs require a carefully designed human system interface. This report centers on redesigning existing DCS displays for an example chemical volume control system (CVCS) at a U.S. nuclear power plant. The crucial nature of the CVCS, which controls coolant levels and boration in the primary system, requires a thorough human factors evaluation of its supporting DCS. The initial digital controls being developed for the DCSs tend to directly mimic the former analog controls. There are, however, unique operator interactions with a digital vs. analog interface, and the differences have not always been carefully factored in the translation of an analog interface to a replacement DCS. To ensure safety, efficiency, and usability of the emerging DCSs, a human factors usability evaluation was conducted on a CVCS DCS currently being used and refined at an existing U.S. nuclear power plant. Subject matter experts from process control engineering, software development, and human factors evaluated the DCS displays to document potential usability issues and propose design recommendations. The evaluation yielded 167 potential usability issues with the DCS. These issues should not be considered operator performance problems but rather opportunities identified by experts to improve upon the design of the DCS. A set of nine design recommendations was developed to address these potential issues. The design principles addressed the following areas: (1) color, (2) pop-up window structure, (3) navigation, (4) alarms, (5) process control diagram, (6) gestalt grouping, (7) typography, (8) terminology, and (9) data entry. Visuals illustrating the improved DCS displays accompany the design recommendations. These nine design principles serve as the starting point to a planned general DCS style guide that can be used across the U.S. nuclear industry to aid in the future design of effective DCS interfaces.
The United States' fleet of nuclear power plants (NPPs) have exceeded their original 40-year licenses and many are seeking license renewals to continue operations into the future. To support continued operation the Department of Energy's (DOE) Light Water Reactor Sustainability Program (LWRS) provides support for utilities to maintain and upgrade their power production capabilities. Control room modernization is one focus area, which aims to modernization the analog control rooms with digital controls and human-system interfaces (HSIs). The Turbine Control System (TCS) is a non-safety related system undergoing modernization efforts at multiple plants and utilities. Considerable human factors research efforts, comprised of expert reviews and operator in the loop studies were performed to develop human factors compliant and usable TCS. This report documents the final phase of the human factors engineering program used to design and validate the new digital TCS. According to the NUREG-0711 review guide, one of the last steps of human factors engineering program prior to implementation is human factors validation. This report details the method, results and conclusions from the human factors validation study of a collaborating utilities TCS slated to be implemented in one of their plants. One control room team consisting of two control room supervisors and two reactor operators participated in the validation. All team members had participated in the BNP TCS training program foregoing the TCS validation. Performance measures included task performance, situation awareness and workload, expert observation of any negative influences of human-system interface features on control room team performance, and interviews with the participating operators. Performance criteria were based on the performance scores and the topics identified by interviews and expert observations. The results showed that the crew using the new TCS clearly could achieve their overall objectives in the test scenarios with sufficient situation awareness. The new TCS compared to the old system provided clear improvements of the control room work regarding shell and chest warming and regarding valve and other system testing. However, a number of Human Engineering Discrepancies (HEDs) were identified. HEDs were prioritized (level 1, 2 or 3) according to potential safety, plant availability, operability or personnel performance consequences. Since no priority 1 HEDs were identified there is no HFE reason not to continue implementation of the TCS. The TCS upgrade is acceptable if the Priority 2 HEDs are resolved and dispositioned in a satisfactory way. Priority 3 HEDs should be noted and considered for future modifications.
Modern digital instrumentation and control (I and C) systems offer nearly unlimited functional capability. However, the complexity of their design (including their system software and application software) is significantly higher than that of conventional, hardwired systems, to the point that it is generally impossible to demonstrate that there are no residual design errors, even when the best development and verification techniques have been applied. When activated by specific conditions, design errors could result in systematic failures, i.e., failures that occur deterministically each time and wherever an activating condition is present. Redundancy could be defeated when the same design error affects multiple channels or systems, and the activating condition affects several of these channels or systems. In the case of safety I and C systems, most of the functions are poised protection functions that must be actuated when and only when a demand situation occurs in the plant. In nuclear power plants, the most dangerous failure mode for such functions generally is failure to actuate, and many measures are taken to protect from such failure mode. This paper considers the other failure modes of safety I and C functions, and also the failure modes of the other I and C functions that are less important to safety. It is not limited to poised functions, and considers other types of functions such as regulation functions or human interface functions. It proposes a framework for analyzing and providing defense against spurious actuations and other incorrect behaviors from digital I and C systems directly interacting with the plant process or with operators: these might be useful for example to justify that design bases for reactor protection are adequate, or to ensure plant performance and availability. (authors)
The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.
A complex optimization criterion that takes into account the integral quadratic error and the stability margin of a robust digital control system for the rectification column used for the butylene-divinyl fraction is proposed. The influence of the weight coefficient, taking into account the ratio of the performance and stability indicators, on the dynamic characteristics of the system is investigated. High system performance and system stability indices over a sufficiently broad range of variation of the parameters of the rectification column are achieved through the use of the proposed optimization criterion and a stability estimation algorithm in the synthesis of a robust digital control system.
This public data set contains openly-documented, machine readable digital research data corresponding to figures published in M.W. Bongard et al., ‘Digital Control and Power Systems for the Pegasus–III Experiment,’ IEEE Transactions on Plasma Science 50, 4021 (2022).
A feedback system for controlling external, long-wavelength magnetohydrodynamic activity is described. The system is comprised of a network of localized magnetic pickup and control coils driven by four independent, low-latency field-programable gate array controllers. The control algorithm incorporates digital spatial filtering to resolve low mode number activity, temporal filtering to correct for frequency-dependent amplitude and phase transfer effects in the control hardware, and a Kalman filter to distinguish the unstable plasma mode from noise.
This report describes work originally performed in FY19 that assembled a workflow enabling formal verification of high-consequence digital controllers. The approach builds on an engineering analysis strategy using multiple abstraction levels (Model-Based Design) and performs exhaustive formal analysis of appropriate levels – here, state machines and C code – to assure always/never properties of digital logic that cannot be verified by testing alone. The operation of the workflow is illustrated using example models and code, including expected failures of verification when properties are violated.
The analog control systems of traditional Nuclear Power Plants (NPPs) are being replaced by digital systems due to the fact that analog Instrumentation and Control (I and C) systems are becoming obsolete and such technology is no longer supported by manufacturers. The purpose of this study is to jointly evaluate the performance of an operator with a Human Machine Interface (HMI) in a NPP digital control room ensuring the efficiency and the safety of the NPP. The validity and the accuracy of the operators' actions are the primary goals that have to be preserved through the emergence of the HMI based in digital systems. The transition from analog to digital control systems leads to a more advanced support of the NPP; Video Display Units (VDUs) are used for monitoring the state of the NPP while alarm systems help for directing attention. The operators, in order to monitor information from the different VDUs, have to switch attention between different screens (alarms systems and control systems). Therefore, a well-established HMI is a significant challenge to the overall operation of the NPP, that actually helps the operators to learn from the available information in detecting possible anomalies and making the right decisions, to ensure safety, and in parallel to diminish the human error. (authors)
The design of high consequence controllers (in weapons systems, autonomy, etc.) that do what they are supposed to do is a significant challenge. Testing simply does not come close to meeting the requirements for assurance. Today circuit designers at Sandia (and elsewhere) typically capture the core behavior of their components using state models in tools such as STATEFLOW. They then check that their models meet certain requirements (e.g. “The system bus must not deadlock” or “both traffic lights at an intersection must not be green at the same time”) using tools called model checkers. If the model checker returns “yes” then the property is guaranteed to be satisfied by the model. However, there are several drawbacks to this industry practice: (1) there is a lot of detail to get right, this is particularly challenging when there are multiple components requiring complex coordination (2) any errors returned by the model checker have to be traced back through the design and fixed, necessitating rework, (3) there are severe scalability problems with this approach, particularly when dealing with concurrency. All this places high demands on the designers who now face not only an accelerated schedule but also controllers of increasing complexity. This report describes a new and fundamentally different approach to the construction of safety-critical digital controllers. Instead of directly constructing a complete model and then trying to verify it, the designer can start with an initial abstract (think “sketch”) model plus the requirements, from which a correct concrete model is automatically synthesized. There is no need for post-hoc verification of required functional properties. Having tool to carry this out will significantly impact the nation’s ability to ensure the safety of high-consequence digital systems. The approach has been implemented in a prototype tool, along with a suite of examples, including ones that reflect actual problems faced by designers. Our approach operates on a variant of Statecharts developed at Sandia called Qspecs. Statecharts are a widely used formalism for developing concurrent reactive systems, supporting scalability through allowing state models containing composite states, which are the serial or parallel composition of substates which can themselves contain statecharts. Statecharts enable an incremental style of development, in which states are progressively refined to incorporate greater detail in an incremental model of software development. Our approach formulates a set of constraints from the structure of the models and the requirements and propagates these constraints to a fixpoint. The solution to the constraints is an inductive invariant along with guards on the transitions. We also show how our approach extends to implementation refinement, decomposition, composition, and elaboration. We currently handle safety requirements written in LTL (Linear Temporal Logic)
Control rooms in nuclear power plants are complex, collaborative working environments rife with potential for human error. As control rooms evolve from analog to digital interface environments, crew communication strategies must change as well. Operators in the analog control room operate the plant and communicate with each other with the help of control boards with large control panels, meters, and switches. Reactor operators could choose a particular set of controls on the particular control board which corresponds to the part of the system of interest. Visual display units (VDU), which became a fixture in the control rooms with the shift to digital human-machine interfaces (HMI), bring benefits for safety and flexibility combining information from various sources. With the increase in automation and the use of digital HMIs operators received their personal sitting workstations where they are able to navigate and operate the plant. The amount of information increased as well as the complexity of monitoring and analyzing the system states. Also computerized systems cause operators to get absorbed by their personal screens and reduce interaction between the crew members. Therefore, the collaboration and coordination of task demands requires vigilance and mutual awareness. The level of automation has an influence on the level of mutual awareness experienced by operators in the control rooms. Teams function to carry out highly interdependent tasks, requiring synthesis and sharing of information to achieve common goals. Improving the performance of the team necessitates the operators to focus on the system, the surrounding environment, and situational awareness about the system states. Collaboration of team members is critical when employing the digital operating systems as the acute awareness of the overall progress of the group and individual activities of the operators drives the team to the desired end-states of the plant operations. Out-of-the loop (OOTL) performance problems can be referred to as the lack of supervisory control, system monitoring, and information processing in the digital HMIs. Under some circumstances Senior Reactor Operators (SRO) struggle to follow the actions of other Reactor Operators (RO) because with the new digital interfaces SROs lose track of how the procedures are carried out by ROs, which results in the loss of three way communication. Mutual awareness plays a significant role in keeping the SROs in the loop of plant operations. This paper will investigate, through literature review and expert interviews, the impact and human errors attributed to the increasing complexity of new digital main control rooms. Comparison of the new digital interfaces with the analog interfaces in nuclear power plants has the potential to shed light on increasing mutual awareness and three way communications between the SROs and ROs. Further, identification of the human errors and human actions can provide beneficial information, suggesting significant and critical improvements that can be implemented in the main control rooms to increase safety and reliability of new technology. Additionally, insights on mutual awareness for analog vs. digital control rooms can serve to improve human reliability.
No abstract prepared.
Monolithic nanoporous metals, derived from dealloying, have a unique bicontinuous solid/void structure that provides both large surface area and high electrical conductivity, making them ideal candidates for various energy applications. However, many of these applications would greatly benefit from the integration of an engineered hierarchical macroporous network structure that increases and directs mass transport. We report on 3D (three-dimensional)–printed hierarchical nanoporous gold (3DP-hnp-Au) with engineered nonrandom macroarchitectures by combining 3D printing and dealloying. The material exhibits three distinct structural length scales ranging from the digitally controlled macroporous network structure (10 to 1000 μm) to the nanoscale pore/ligament morphology (30 to 500 nm) controlled by dealloying. Supercapacitance, pressure drop, and catalysis measurements reveal that the 3D hierarchical nature of our printed nanoporous metals markedly improves mass transport and reaction rates for both liquids and gases. Our approach can be applied to a variety of alloy systems and has the potential to revolutionize the design of (electro-)chemical plants by changing the scaling relations between volume and catalyst surface area.
The Advanced Reactor Control and Operations (ARCO) facility was constructed in January 2018 to serve as a test bed for advanced reactor control rooms and operator support systems. Since then, it has supported human-machine interface user experience research, fault detection and mitigation technology development, control room concept of operations development, and remote operations research. ARCO serves as the control room for the Compact Integral Effects Test (CIET) facility, which replicates the primary-side flow paths and thermal-hydraulic behavior of a fluoride-salt-cooled high-temperature reactor (FHR) using simulant fluids and scaling principles. New reactor designs feature different operating conditions and scenarios than those in existing reactors. ARCO supports the research and development of digital tools for operator communications, intuitive real-time data analysis, online health monitoring and prognostics, and control room cybersecurity. By integrating these different technologies, ARCO acts as a prototypical control system to iteratively develop methods and tools of operation in advanced small modular nuclear reactors. This paper describes the features of and challenges to operating advanced small modular reactors underlying the design basis for ARCO and its operator support systems.
The U.S. fleet of nuclear power plants is aging, and efforts are being made to modernize instrumentation and control systems including integration of digital human-machine interfaces (HMIs) into the control room. Automation and control technologies have advanced since original systems were installed in the plants. This presents unique opportunities and challenges in ensuring the replacements are a benefit to the operators and the overall safe and reliable operation of the plant. We discuss trends we have observed from assisting utilities in their modernization efforts. Automation and evolving control rooms come with their own host of problems that existing human factors and engineering methods fail to capture. Traditional approaches are analytical approaches to ensuring reliability. Here we discuss some of the shortfalls of these traditional approaches as plants become increasingly more complex. We suggest that ensuring reliability for modernized and next generation control room will require expanding the scope of what was traditionally considered human factors as well as exploring novel approaches and methodologies for dealing with complexity and rapidly advancing technology. (authors)
SLAC National Accelerator Laboratory has built and is currently operating a first generation prototype Marx klystron modulator to meet ILC specifications. Under development is a second generation prototype, aimed at improving overall performance, serviceability, and manufacturability as compared to its predecessor. It is designed around 32 cells, each operating at 3.75 kV and correcting for its own capacitor droop. Due to the uniqueness of this application, high voltage gate drivers needed to be developed for the main 6.5 kV and droop correction 1.7 kV IGBTs. The gate driver provides vital functions such as protection of the IGBT from over-voltage and over-current, detection of gate-emitter open and short circuit conditions, and monitoring of IGBT degradation (based on collector-emitter saturation voltage). Gate drive control, diagnostic processing capabilities, and communication are digitally implemented using an FPGA. This paper details the design of the gate driver circuitry, component selection, and construction layout. In addition, experimental results are included to illustrate the effectiveness of the protection circuit.
Not Available