Digital Radiography

System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

Source record↗

Real-Time Digital Radiography Upgrade

The objective of the task is to upgrade an existing real-time digital radiography system by replacing an aged image intensifier tube with an amorphous silicon digital x-ray imager. The real-time digital radiography system at GSFC is currently fitted with image intensifier tube with a 4 or 2 inch diameter active area with higher resolution at the smaller area. The image intensifier is exhibiting deterioration in sensitivity associated with extended use and is in need of replacement.

Parker, Bradford H.↗

Using Digital Radiography To Image Liquid Nitrogen in Voids

Digital radiography by use of (1) a field-portable x-ray tube that emits low-energy x rays and (2) an electronic imaging x-ray detector has been found to be an effective technique for detecting liquid nitrogen inside voids in thermal-insulation panels. The technique was conceived as a means of investigating cryopumping (including cryoingestion) as a potential cause of loss of thermal insulation foam from space-shuttle external fuel tanks. The technique could just as well be used to investigate cryopumping and cryoingestion in other settings. In images formed by use of low-energy x-rays, one can clearly distinguish between voids filled with liquid nitrogen and those filled with gaseous nitrogen or other gases. Conventional film radiography is of some value, but yields only non-real-time still images that do not show time dependences of levels of liquids in voids. In contrast, the present digital radiographic technique yields a succession of images in real time at a rate of about 10 frames per second. The digitized images can be saved for subsequent analysis to extract data on time dependencies of levels of liquids and, hence, of flow paths and rates of filling and draining. The succession of images also amounts to a real-time motion picture that can be used as a guide to adjustment of test conditions.

Cox, Dwight↗

Application of Digital Radiography to Weld Inspection for the Space Shuttle External Fuel Tank

This slide presentation reviews NASA's use of digital radiography to inspect the welds of the external tanks used to hold the cryogenic fuels for the Space Shuttle Main Engines. NASA has had a goal of replacing a significant portion of film used to inspect the welds, with digital radiography. The presentation reviews the objectives for converting to a digital system from film, the characteristics of the digital system, the Probability of detection study, the qualification and implementation of the system.

Ussery, Warren↗

Digital Radiography Qualification of Tube Welding

The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

Carl, Chad↗

Simulating the X-Ray Image Contrast to Set-Up Techniques with Desired Flaw Detectability

The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is being developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing X-ray detector resolution for crack detection. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

Koshti, Ajay M.↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Material Identification Using Dual Energy X-ray Absorptiometry

Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a 1 , a 2 , a 3 } or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {$\frac{a_{2}}{a_{1}}$, $\frac{a_{3}}{a_{1}}$} or estimated effective atomic number $\hat{Z}$ from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable $\frac{a_{3}}{a_{1}}$ ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.

36 MATERIALS SCIENCE↗

The Steel Equivalency Workbook: An X-Ray Transmission Calculator

The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.

36 MATERIALS SCIENCE↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

X ray attenuation measurements for high-temperature materials characterization and in-situ monitoring of damage accumulation

The scope of this dissertation is to develop and apply x ray attenuation measurement systems that are capable of: (1) characterizing density variations in high-temperature materials, e.g., monolithic ceramics, ceramic and intermetallic matrix composites, and (2) noninvasively monitoring damage accumulation and failure sequences in ceramic matrix composites under room temperature tensile testing. This dissertation results in the development of: (1) a point scan digital radiography system, and (2) an in-situ x ray material testing system. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. Further in-situ radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction bonded silicon nitride matrix. It is concluded that pretest, in-situ, and post test x ray imaging can provide for greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Flight-vehicle materials, structures, and dynamics - Assessment and future directions. Vol. 4 - Tribological materials and NDE

The present volume on tribological materials and NDE discusses liquid lubricants for advanced aircraft engines, a liquid lubricant for space applications, solid lubricants for aeronautics, and thin solid-lubricant films in space. Attention is given to the science and technology of NDE, tools for an NDE engineering base, experimental techniques in ultrasonics for NDE and material characterization, and laser ultrasonics. Topics addressed include thermal methods of NDE and quality control, digital radiography in the aerospace industry, materials characterization by ultrasonic methods, and NDE of ceramics and ceramic composites. Also discussed are smart materials and structures, intelligent processing of materials, implementation of NDE technology on flight structures, and solid-state weld evaluation.

Fusaro, Robert L.↗

Ruggedized Minicamera

When NASA needed a video camera for the Space Shuttle, they turned to Videospection, Inc., a company specializing in cameras for unusual and demanding applications. Videospection developed a "ruggedized" minicamera, measuring 7 1/2" in diameter and enclosed in a sealed aluminum housing. This led to two new commercial models, utilized where ruggedness, high resolution and reliability are required. Other Videospection cameras are used for internal inspection of nuclear reactors, digital radiography and flaw detection applications.

Source record↗

Uses of Computed Tomography in the NASA Materials Science Program

Computed Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used to characterize materials in preparation for flight, to determine thermal expansion values, and to examine long duration space grown materials, i.e. meteorites. The work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. This will include both the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along single crystals of germanium-silicon alloys. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication and installation of a single zone furnace incorporating a heat pipe to ensure of high temperature uniformity. At the time of writing the thermal expansion of lead has been measured from room temperature to 900 C. Three methods are available. Digital radiography enable length changes to be determined. Prior to melting the sample is small than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the lead alloyed with antimony is ready for scanning. This corresponds to the planned composition of Dr. Poirier's flight experiment. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the iron-nickel phase has coarsened during slow cooling over hundreds of millions of years.

Engel, H. Peter↗

Spinoff from Space Astronomy

American Science and Engineering (AS&E) built NASA's first x-ray telescope, flown on OSO-4 (Orbiting Solar Observatory), and developed the x-ray detectors that operated flawlessly for four years aboard SAS-1 (Small Astronomy Satellite). The experience AS&E acquired in detecting and processing cosmic x-rays gave the company a broad technology base for commercial applications. Among the commercial products that stemmed from AS&E's space technology are: Micro Dose x-ray scanner for medical use; a digital radiography diagnosis, a system for nondestructive testing of manufactured products; a system of load management for electric utilities; and additional specialized instruments.

Source record↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗