At least 19 records

Wideband Spectroscopy: The Design and Implementation of a 3 GHz, 2048 Channel Digital Spectrometer

A state-of-the-art digital Fourier Transform spectrometer has been developed, with a combination of high bandwidth and fine resolution unavailable elsewhere. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved Analog-to-Digital Converters (ADC). This 6 Gsps (giga sample per second) digital representation of the analog signal is then processed through an FPGA-based streaming Fast Fourier Transform (FFT), the key development described below. Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers. The implementation, results and underlying math for this spectrometer, as well as potential for future extension to even higher bandwidth, resolution and channel orthogonality, needed to support proposed future advanced atmospheric science and radioastronomy, are discussed.

field programmable gate array↗

Wideband Spectroscopy: The Design and Implementation of a 3 GHz Bandwidth, 8192 Channel, Polyphase Digital Spectrometer

A family of state-of-the-art digital Fourier transform spectrometers has been developed, with a combination of high bandwidth and fine resolution unavailable elsewhere. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved Analog-to-Digital Converters, (ADC). This 6 Gsps (giga-sample per second) digital representation of the analog signal is then processed through an FPGA-based streaming Fast Fourier Transform (FFT), the key development described below. Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers. the implementation, results and underlying math for this spectrometer, as well as, potential for future extension to even higher bandwidth, resolution and channel orthogonality, needed to support proposed future advanced atmospheric science and radioastronomy, are discussed.

field programmable gate array↗

Digital Spectrometers for Interplanetary Science Missions

A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

polyphase filter bank spectrometer (PFB)↗

Low-Power CMOS Digital Autocorrelator Spectrometer

Prototype digital autocorrelator spectrometer circuit designed and built as assembly of few very-large-scale integrated (VLSI) complementary metal oxide/semiconductor (CMOS) circuit chips. Spectrometer contains 128 frequency channels and operates at clock rate of as much as 40 MHz. Total dc power needed is only 6 W. Digital autocorrelator spectrometer consists of four 32-channel autocorrelator chips that collectively produce 128-point spectrum of input signal as computed by use of Fourier transform.

Chandra, Kumar M.↗

Broad-Bandwidth FPGA-Based Digital Polyphase Spectrometer

With present concern for ecological sustainability ever increasing, it is desirable to model the composition of Earth s upper atmosphere accurately with regards to certain helpful and harmful chemicals, such as greenhouse gases and ozone. The microwave limb sounder (MLS) is an instrument designed to map the global day-to-day concentrations of key atmospheric constituents continuously. One important component in MLS is the spectrometer, which processes the raw data provided by the receivers into frequency-domain information that cannot only be transmitted more efficiently, but also processed directly once received. The present-generation spectrometer is fully analog. The goal is to include a fully digital spectrometer in the next-generation sensor. In a digital spectrometer, incoming analog data must be converted into a digital format, processed through a Fourier transform, and finally accumulated to reduce the impact of input noise. While the final design will be placed on an application specific integrated circuit (ASIC), the building of these chips is prohibitively expensive. To that end, this design was constructed on a field-programmable gate array (FPGA). A family of state-of-the-art digital Fourier transform spectrometers has been developed, with a combination of high bandwidth and fine resolution. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved analog-to-digital converters (ADCs). This 6-Gsps (gigasample per second) digital representation of the analog signal is then processed through an FPGA-based streaming fast Fourier transform (FFT). Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers.

Jamot, Robert F.↗

Low power, CMOS digital autocorrelator spectrometer for spaceborne applications

A 128-channel digital autocorrelator spectrometer using four 32 channel low power CMOS correlator chips was built and tested. The CMOS correlator chip uses a 2-bit multiplication algorithm and a full-custom CMOS VLSI design to achieve low DC power consumption. The digital autocorrelator spectrometer has a 20 MHz band width, and the total DC power requirement is 6 Watts.

Chandra, Kumar↗

Analysis of a crossed Bragg cell acousto-optical spectrometer for SETI

The search for radio signals from extraterrestrial intelligent beings (SETI) requires the use of large instantaneous bandwidth (500 MHz) and high resolution (20 Hz) spectrometers. Digital systems with a high degree of modularity can be used to provide this capability, and this method has been widely discussed. Another technique for meeting the SETI requirement is to use a crossed Bragg cell spectrometer as described by Psaltis and Casasent. This technique makes use of the Folded Spectrum concept, introduced by Thomas. The Folded Spectrum is a 2-D Fourier Transform of a raster scanned 1-D signal. It is directly related to the long 1-D spectrum of the original signal and is ideally suited for optical signal processing. The folded spectrum technique has received little attention to date, primarily because early systems made use of photographic film which are unsuitable for the real time data analysis and voluminous data requirements of SETI. An analysis of the crossed Bragg cell spectrometer is presented as a method to achieve the spectral processing requirements for SETI. Systematic noise contributions unique to the Bragg cell system will be discussed.

NASA Discipline Number 52-60↗

Analysis of a crossed Bragg-cell acousto optical spectrometer for SETI

The search for radio signals from extraterrestrial intelligent (SETI) beings requires the use of large instantaneous bandwidth (500 MHz) and high resolution (20 Hz) spectrometers. Digital systems with a high degree of modularity can be used to provide this capability, and this method has been widely discussed. Another technique for meeting the SETI requirement is to use a crossed Bragg-cell spectrometer as described by Psaltis and Casasent (1979). This technique makes use of the Folded Spectrum concept, introduced by Thomas (1966). The Folded Spectrum is a two-dimensional Fourier Transform of a raster scanned one-dimensional signal. It is directly related to the long one-dimensional spectrum of the original signal and is ideally suited for optical signal processing.

Gulkis, S.↗

Fully-polarimetric millimeter-wave spectrometers for measurement of Earth's magnetic field

Earth’s ionosphere responds dynamically over a wide range of temporal and spatial scales to changes in the magnetosphere and solar wind from above, and to neutral atmospheric dynamics from below. Determining the dynamics and coupling of Earth's magnetosphere, ionosphere, and atmosphere by vector magnetic field measurements at all altitudes is essential, as the field plays a major role in controlling the distribution of ionospheric plasma. It is difficult to measure the magnetic B-field, either locally or globally, at the altitudes of the upper mesosphere and lower thermosphere (UMLT) where the transfer of energy and momentum between the plasma and neutral components of the system occur. The 118-GHz imaging magnetometer will measure all four Stokes parameters as a function of frequency about the Zeeman-split center of the 118-GHz molecular oxygen line. We are developing an array of fully-polarimetric millimeterwave radiometer/spectrometers operating near 118 GHz. These low cost, low power, low mass polarimetric 118 GHz millimeter-wave array receivers do not require cooling to meet the sensitivity requirements. With digital spectrometers we will be able to integrate the complete end-to-end system. This work will enable a second generation small satellite mission with an off-nadir viewing instrument comprised of 120 such receivers (arranged so that each spot on the Earth is observed simultaneously by four receivers each) that will globally map the magnetic field in the mesosphere at 42-76 km altitude at a horizontal resolution ~100 km with 1-sigma error of 40-120 nT, in typical mesospheric temperature conditions.

Mannucci, Anthony↗

COSMIR-H: an Airborne Hyperspectral Microwave Sounder for Thermodynamic Sensing of the Planetary Boundary Layer

The NASA Planetary Boundary Layer (PBL) Incubation Study Team Report lists hyperspectral microwave (HMW) sensors as one of the “essential components” of a future global PBL observing system. HMW sensors will provide profiles of the PBL thermodynamic (temperature and water vapor) structure in synergy with passive infrared sounders and to complement active measurements (e.g., lidar and radar). While many simulation studies have been performed showing the benefit of HMW observations, measurements are needed to demonstrate the efficacy of hyperspectral retrievals. The Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) is an airborne sensor that is currently being modified with digital spectrometers to create a HMW sounder with 4-MHz spectral resolution at 50.0-58.0 GHz and 175-191 GHz. The new CoSMIR-Hyperspectral (CoSMIRH) will collect measurements in July 2024 on the highaltitude NASA ER-2 aircraft. These measurements will advise on current knowledge gaps in HMW sounding and inform decisions on future spaceborne HMW sensors

radiometry↗

Remote sensing of Earth's atmosphere and surface using a digital array scanned interferometer: A new type of imaging spectrometer

The capabilities of the digital array scanned interferometer (DASI) class of instruments for measuring terrestrial radiation fields over the visible to mid-infrared are evaluated. DASI's are capable of high throughput, sensitivity and spectral resolution and have the potential for field-of-view spatial discrimination (an imaging spectrometer). The simplicity of design and operation of DASI's make them particularly suitable for field and airborne platform based remote sensing. The long term objective is to produce a versatile field instrument which may be applied toward a variety of atmospheric and surface studies. The operation of DASI and its advantages over other spectrometers are discussed.

Hammer, Philip D.↗

Applications of correlator chips in radio science

Spectral line observations in radio astronomy require simultaneous power estimation in many (often hundreds to thousands) frequency bins. Digital autocorrelation spectrometers, which appeared thirty years ago, are now being implemented in VLSI. The same architecture can be used to implement transversal digital filters. This was done at the Arecibo Observatory for pulse compression in radar observations of Venus.

Hagen, John B.↗

Electric Field Induced Spectra of H sub 2 and D sub 2

The frequencies of four Q-branch lines of H2 and five Q-branch lines of D2 were measured as a function of density, and their shifts were observed to be in the linear region. The individual slopes and extrapolated zero density frequency of each line was determined. Hydrogen was measured for polarizability using the integrated intensity of the Q1(0) and S1(1), H2 absorption line. A highly automated technique for determining the response function of the spectrometer using digitally recorded data is presented. For the Q1(0) and Q1(1) lines of H2 the halfwidths were measured as a function of electric field intensity at constant pressure, and again at several densities and compared to previously measured widths. Technical and operational details of equipment built for this experiment, and for the five-meter Littrow spectrometer used, are described. Modifications of the spectrometer optics to accept the Stark cell are discussed.

Boyd, William Joseph↗

Further development and testing of the metabolic gas analyzer

Continued development of a metabolic monitor utilizing a mass spectrometer and digital computer to perform measurements and data reduction, is reported. The device prints-out breath-by-breath values for 02 consumption, C02 production, minute volume and tidal volume. The flow is measured by introduction of a tracer gas to the expired gas stream. Design modifications to reduce pressure drop in the flow splitter to one inch of water at 600 liters/min flow and to extend the range of linear flow measurement to 1000 liters/min are discussed.

Source record↗