Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct Current (DC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Harnessing distributed GPU computing for generalizable graph convolutional networks in power grid reliability assessments

Although machine learning (ML) has emerged as a powerful tool for rapidly assessing grid contingencies, prior studies have largely considered a static grid topology in their analyses. This limits their application, since they need to be re-trained for every new topology. Here, this paper explores the development of generalizable graph convolutional network (GCN) models by pre-training them across a range of grid topologies and contingency types. We found that a GCN model with auto-regressive moving average (ARMA) layers with a line graph representation of the grid offered the best predictive performance in predicting voltage magnitudes (VM) and voltage angles (VA). We introduced the concept of phantom nodes to consider disparate grid topologies with a varying number of nodes and lines. For pre-training the GCN ARMA model across a variety of topologies, distributed graphics processing unit (GPU) computing afforded us significant training scalability. The predictive performance of this model on grid topologies that were part of the training data is substantially better than the direct current (DC) approximation. Although direct application of the pre-trained model to topologies that are not part of the grid is not particularly satisfactory, fine-tuning with small amounts of data from a specific topology of interest significantly improves predictive performance. In general, this paper highlights the feasibility of training large-scale GNN models to assess the reliability of power grids by considering a wide variety of grid topologies and contingency types. With the advent of foundational models in ML and the exponential increase in GPU computing clusters, generalizable ML models will significantly enhance how utilities manage power systems and make decisions in real-time or near-real-time.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

High-performance photonic transformers for DC voltage conversion

Abstract Direct current (DC) converters play an essential role in electronic circuits. Conventional high-efficiency DC voltage converters, especially step-up type, rely on switching operation, where energy is periodically stored within and released from inductors and/or capacitors connected in a variety of circuit topologies. Since these energy storage components, especially inductors, are fundamentally difficult to scale down, miniaturization of switching converters proves challenging. Furthermore, the resulting switching currents produce significant electromagnetic noise. To overcome the limitations of switching converters, photonic transformers, where voltage conversion is achieved through light emission and detection processes, have been demonstrated. However, the demonstrated efficiency is significantly below that of the switching converter. Here we perform a detailed balance analysis and show that with a monolithically integrated design that enables efficient photon transport, the photonic transformer can operate with a near-unity conversion efficiency and high voltage conversion ratio. We validate the theory with a transformer constructed with off-the-shelf discrete components. Our experiment showcases near noiseless operation and a voltage conversion ratio that is significantly higher than obtained in previous photonic transformers. Our findings point to the possibility of a high-performance optical solution to miniaturizing DC power converters and improving the electromagnetic compatibility and quality of electrical power.

42 ENGINEERING↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternating Current Photovoltaic Effect

It is well known that the photovoltaic effect produces a direct current (DC) under solar illumination owing to the directional separation of light-excited charge carriers at the p–n junction, with holes flowing to the p-side and electrons flowing to the n-side. In this study, we found that apart from the DC generated by the conventional p–n photovoltaic effect, there is another new type of photovoltaic effect that generates alternating current (AC) in the nonequilibrium states when the illumination light periodically shines at the junction/interface of materials. The peak current of AC at high switching frequency can be much higher than that from DC. The AC cannot be explained by the established mechanisms for conventional photovoltaics; instead, it is suggested to be a result of the relative shift and realignment between the quasi-Fermi levels of the semiconductors adjacent to the junction/interface under the nonequilibrium conditions, which results in electron flow in the external circuit back and forth to balance the potential difference between two electrodes. By virtue of this effect, the device can work as a high-performance broadband photodetector with extremely high sensitivity under zero bias; it can also work as a remote power source providing extra power output in addition to the conventional photovoltaic effect.

36 MATERIALS SCIENCE↗

Machine Learning-Assisted Stability Boundary Determination of Multiport Autonomous Reconfigurable Solar Power Plants

The multiport autonomous reconfigurable solar (MARS) power plant is a promising solution to integrate renewable resources and energy storage systems into the alternating current (ac) power grid and an high-voltage direct current (HVdc) link. In the MARS system, various input power sources are connected to the individual submodules (SMs) through direct current (dc)–dc converters. However, the presence of external power sources can result in unbalanced capacitor voltages of SMs, thereby violating stability constraints under multiple/diverse operating conditions. This article aims to address the gap by accurately determining the stability boundary of the MARS system. As such, a novel machine learning (ML)-assisted energy balancing control (EBC) criterion is proposed. Further, in conjunction with a refined EBC, this approach ensures balanced capacitor voltages across various types of SMs, significantly enhancing the overall system efficiency. The proposed EBC criterion effectively controls EBC activation and deactivation, achieving remarkable accuracy. Both power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulations and control hardware-in-the-loop (cHIL) tests are conducted to validate the feasibility and efficiency of the proposed method. By combining the EBC and ML-assisted EBC criterion, efficient energy management is achieved for systems featuring multiple input power sources, such as MARS. This approach enables the system to fully exploit its potential across an expanded operational range while upholding high-efficiency standards.

14 SOLAR ENERGY↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Electrorefining Bismuth Using AC Superimposed DC Waveforms

Bismuth has been successfully electrorefined using both direct current (DC) and alternating current (AC) superimposed DC waveforms on a kilogram scale at Brigham Young University (BYU) in Provo, Utah. Finding a suitable surrogate for Pu Electrorefining has always been a technical challenge. This work allows the possibility to improve Pu electrorefining with nonradioactive material at universities, which greatly reduces the cost at Lawrence Livermore National Laboratory (LLNL) for improving Pu Electrorefining. Several possible surrogates (Ce, In, Sn, Zn, and Bi) were selected based on their ability to mimic the Pu electrorefining process. Ce and In electrorefining experiments were conducted at the same temperature as Pu electrorefining in CaCl 2 while Sn, Zn, and Bi, electrorefining experiments were conducted at a lower temperature in a eutectic molten salt composed of LiCl, KCl, and CaCl 2 . The electrorefining experiments using Ce with a Ga impurity did not produce a cathode ring. While the remaining Ce anode after electrorefining was significantly less than what was initially added, Scanning Electron Microscopy with Energy Dispersive X-Ray (SEM-EDX) analysis showed that the Ce had been oxidized and formed a colloid with the surrounding molten salt. This is supported in the literature by analysis of Ce-rich CaCl 2 mixtures. All the electrorefining experiments except for the Ce electrorefining experiments did not introduce an impurity to the system. Electrorefining experiments with In showed that the InCl 3 volatilized out of the molten salt to an extent that only a low current (<<1 A) could be supported without decomposing the molten salt. Zn electrorefining experiments had marginal success, however an easily separable product was not formed. The Zn had to be rinsed from the salt after the experiment. Of the identified potential surrogates. Investigated, only Bi and Sn yielded an easily separable product ring, which enables quantitative analysis of yields and coulombic efficiencies. Bismuth was first identified as a surrogate at BYU, while Sn was identified as a surrogate at LLNL later. Thus, the electrorefining experiments conducted at BYU using AC superimposed DC waveforms used Bi as the metal to be electrorefined.

36 MATERIALS SCIENCE↗

An SF 6 gas-insulated −500 kV DC conical insulator vacuum feedthrough

A test electrode was biased to −500 kV direct current (DC) by means of a novel SF 6 gas-insulated conical alumina insulator feedthrough. The design enables the extreme high vacuum conditions required by spin-polarized electron sources by reducing the photogun vacuum chamber volume compared to coaxial cylindrical insulators. In contrast to conventional inverted-insulator photogun designs that rely on solid dielectric interfaces for high-voltage terminations, the present design employs a pressurized SF 6 intervening volume between a conical alumina insulator and a modified commercial epoxy high-voltage cable receptacle. Here, this approach enables the use of commercially available cable hardware while extending the demonstrated operating voltage of solid feedthroughs. A maximum voltage of −500 kV was applied to a test electrode attached to the narrow end of the feedthrough inside a chamber filled with SF 6 at 170.3 kPa (10 psig) and later under vacuum to −259 kV, limited by field emission. The results demonstrate that a commercial high-voltage cable combined with a custom-designed SF 6 gas-insulated vacuum feedthrough can be used to bias photogun electrodes to −500 kV DC.

Palacios-Serrano, Gabriel [Thomas Jefferson Nation↗

Soft-switching, high performance single-phase AC-DC converter

A soft-switching, high-performance single-phase alternating current (AC)-direct current (DC) converter is provided. The AC-DC converter described herein provides a new circuit topology for single-stage, single-phase or multi-phase AC-DC power conversion with power factor correction (PFC) and galvanic isolation using a high-frequency isolation transformer. The AC-DC converter improves power conversion efficiency and power density—two of the most important metrics for a power converter. It achieves soft switching for high frequency switches in the circuit, leading to higher efficiency and lower electromagnetic interference (EMI).

Ayyanar, Rajapandian↗

A study on dc fault handling of dc-dc converter based on series and parallel connected DABs in MVdc applications

With the increase of direct current (dc) based power generating stations and loads, multi-terminal medium voltage dc (MT-MVdc) systems are gaining popularity. The dc sources and loads are interfaced with the MT-MVdc systems using series and parallel connected dual-active-bridge (SP-DAB). In this paper, the dc fault ride through procedure of SP-DAB meant for MT-MVdc application is analyzed. The need for dc breaker (DCB) under the requirements of MT-MVdc is established through EMT simulation studies. It is shown that an additional dc filter capacitor is essential at the output terminals of the SP-DAB to ride through the dc faults.

Jaldanki, Sreenivasa [ORNL] (ORCID:000000028122322↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector.Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation.The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

Vossos, Evangelos↗

NETL Plastic Pipes Project (Final Report)

Plastic or composite pipelines have been the bane of the utility locating industry because they are neither conductive nor magnetic which are the properties traditionally used to locate buried utilities. Ground penetrating radar (GPR) is an effective geophysical tool for locating plastic/composite pipelines where resistive cover allows for adequate penetration of radar energy. However, GPR has limited applicability in areas where the soil cover is conductive due to significant clay and/or salt content. This study examines complementary near-surface geophysical methods that are potentially useful for locating buried plastic/composite pipelines, either singly or in combination. Specifically, this modeling study used computational numerical methods to forward model the response of GPR, resistivity, seismic, gravity gradiometry, and photoacoustic/thermoacoustic imaging methods to plastic/composite pipelines for various scenarios including: (1) pipe diameters ranging between 2 in. to 12 in.; (2) burial depths ranging between 3 ft. to 4 ft.; (3) various degrees in contrast in physical properties (i.e., electrical permittivity, elasticity, resistivity, density); and (4) various experimental acquisition choices (e.g., GPR radar and seismic source frequencies, electrode spacing). Numerical modeling performed herein reconfirmed that GPR is the preferred method for detecting/locating plastic pipelines. A caveat for GPR detection is that the material covering the plastic pipe (trench fill material and adjacent soil) must be sufficiently resistive to allow the two-way propagation to the required depth of investigation and back to the surface. GPR was the only method modeled in this study that can be used to directly detect plastic pipelines of 2-in.-diameter and larger when buried 3-ft-deep. GPR data processing and imaging also can determine pipe depth, pipe diameter, trench dimensions, and moisture conditions. Seismic modeling results suggest that direct detection of a 12-in.-diameter plastic pipe at 3-ft.-depth may be possible under favorable conditions; however, the associated signature would be weak (e.g., surface- to S-wave, backscattered surface-waves, and/or forward scattered surface-waves to S-wave). Direct pipe detection under field conditions with noise and strong lateral geologic heterogeneity is doubtful. Numerical modeling also suggests that plastic pipelines can be indirectly located by detecting the trench in which they are buried. GPR, direct current (DC) resistivity, and seismic methods have the potential to locate the pipeline trench if there is sufficient contrast between the trench-wall and trench-fill materials for the physical property being measured by each method (i.e., electrical permittivity for GPR; resistivity for DC resistivity; or density, compressional velocity, or shear velocity for seismic). Modeling also indicated that currently available (commercial) gravity gradiometers would be unable to directly detect/locate plastic pipelines ≤ 8-in.-diameter when buried 3-ft.-deep given the typical instrument noise floor for field surveying as well as the expected density variations due to geologic heterogeneity. The numerical modeling performed in this project did not identify a universal geophysical technology that can locate buried plastic pipelines in all parts of the United States (although GPR is suggested for all areas with resistive cover). However, the project results suggest that a towed land streamer simultaneously acquiring multiple geophysical data types including multi-offset GPR, multi-channel DC resistivity, seismic geophone- and/or distributed acoustic sensing (DAS), and potentially photoacoustic/thermoacoustic data would be an appropriate platform for locating buried plastic pipeline. Moreover, the complementary multiphysics data acquired by a towed land streamer would permit the use of joint and/or cooperative inversion frameworks for a more rigorous and consistent data interpretation.

42 ENGINEERING↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗