Search NASA⌕ Search

SEARCH · Search NASA

Results for “Discomfort glare”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)

LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.

59 BASIC BIOLOGICAL SCIENCES↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correspondence: A new two-step approach for evaluating discomfort from glare

While there are several rating scales commonly used to measure discomfort from glare sources, there are issues in the design of these scales that lead to noise in the data and in turn contribute to continued disagreement about the prediction of discomfort. Problems with rating scales include uncertainty about the meaning of magnitude descriptors, limited analysis opportunities available for some rating scales, inconsistent labelling of scale descriptors between studies that are using the “same” scale, the inability for subjects to indicate the lack of discomfort, and that it is uncertain where lies the borderline between comfort and discomfort. This paper proposes a new two-step scale for rating discomfort from glare.

99 GENERAL AND MISCELLANEOUS↗

What to measure and report in studies of discomfort from glare for pedestrian applications

We report in outdoor environments after dark, pedestrians may experience discomfort from glare caused by lighting. Several models to predict discomfort from glare have been proposed or extended for pedestrian applications; these models use different luminous and geometrical quantities to predict discomfort. Consistent measurements and reporting in studies of discomfort from glare are important for identifying best performing models; however, previous studies proposing a new model tended to only report the performance of the new model and its quantities. This practice makes it difficult to evaluate how a new model performs compared to other existing models. To promote more consistent and complete reporting, this research note proposes measuring and reporting all relevant quantities that are used in existing models. This can make it easier for researchers to use a study dataset to compare the performance of several models or to combine datasets from several studies to address between-study variance.

42 ENGINEERING↗

Predicting discomfort from glare with pedestrian-scale lighting: A comparison of candidate models using four independent datasets

After dark, pedestrians may experience discomfort from glare caused by outdoor lighting. While several models for measuring discomfort have been proposed, there is no consensus as to which model should be used. The performances of different models were investigated using datasets from four independent studies, comparing the degree of association between model predictions and subjective ratings, and the ability of a model to distinguish between discomfort and non-discomfort situations. The models tested are those proposed by Petherbridge and Hopkinson in 1950, Schmidt-Clausen and Bindels in 1974, Bullough et al. in 2008 and Lin et al. in 2014 and 2015. They also include two quantities: direct illuminance at the eye from the glare source and average source luminance. Of the models tested, the best performance was found using either the model proposed by Bullough et al. in 2008 or by direct illuminance at the eye.

Abboushi, B.↗

The Position Index of Overhead LED Sources Under Different Spectral Power Distributions and Background Luminances

The position index was developed by Luckiesh and Guth in 1949 and is widely used in discomfort glare models to account for the position of the glare source when predicting the presence and magnitude of visual discomfort. The applicability of this index to modern LED sources has not been evaluated; however, it is of concern due to potentially higher luminance levels of LEDs compared to the sources used by Luckiesh and Guth. Furthermore, the position index of overhead sources beyond 60° above the line of sight has not been quantified. An experiment was conducted using a hemispherical apparatus with LED sources. The position of the light source, background luminance, the spectral power distribution, and anchor (starting luminance level before adjustment) were varied and two procedures were used to determine the position index of these sources. Data from 29 participants indicate that overhead sources located 60° or 80° above the line of sight were detectable and their position index can be quantified. The position index values were found to be higher than those reported in previous studies, suggesting that anchor bias and the small luminance range in previous studies likely influenced their position index values. No differences were found in position index values by spectral power distribution, background luminance, participant age group, or eyeglass wearing. In conclusion, the position index values reported in this study account for range and anchor bias, providing a better estimate that should be incorporated into discomfort glare models.

Discomfort glare↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design evaluation in technology assessment: Illustrated by auditory impedance and sound distribution problems

Technology is considered as a culture for changing a physical world and technology assessment questions the inherent cultural capability to modify power and material in support of living organisms. A comprehensive goal-parameter-synthesis-criterion specification is presented as a basis for a rational assessment of technology. The thesis queries the purpose of the assessed problems, the factors considered, the relationships between factors, and the values assigned those factors to accomplish the appropriate purpose. Stationary and sequential evaluation of enviro-organismic systems are delegated to the responsible personalities involved in design; from promoter/designer through contractor to occupant. Discussion includes design goals derived from organismic factors, definitions of human responses which establish viable criteria and relevant correlation models, linking stimulus parameters, and parallel problem-discipline centered design organization. A consistent concept of impedance, as a degradation in the performance of a specified parameter, is introduced to overcome the arbitrary inoperative connotations of terms like noise, discomfort, and glare. Applications of the evaluative specification are illustrated through design problems related to auditory impedance and sound distribution.

Halldane, J. F.↗