Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Temperature Sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗

Characterizing soil water content variability across spatial scales from optimized high-resolution distributed temperature sensing technique

Fiber-optic Distributed Temperature Sensing, when combined with the Single-probe Heat-pulse technique can measure soil moisture (θ) across spatial scales. The key limitation of this system is in obtaining the relationship between soil thermal conductivity (λ) and θ for a specific field. Using the Department of Energy Atmospheric Radiation Measurement (ARM) site, this study tested a new methodology to account for the spatial variability in the λ-θ relationship using a Gaussian processes model. The resulting accurate θ measurements (RMSE = 0.03 m 3 m –3 ) were used to characterize the spatial variability of θ across scales and to develop an empirical equation that can correct for the changes in the θ spatial variability observed at different spatial resolutions. In addition, the number of required samples to accurately characterize θ and its variability over scales ranging from 5 m and 350 m were estimated. Finally, these findings provide key information to scale soil moisture from centimeters to hundreds of meters for process understanding.

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE: Well 16B(78)-32 Distributed Temperature Sensing Data from April and May 2024

This dataset includes Neubrex Energy Services fiber optic distributed temperature sensing (DTS) data from well 16B(78)-32 during stimulation and circulation, including interaction with well 16A(78)-32, during April and May 2024. The DTS data are stored in HDF5 file format and are accompanied by a PowerPoint report on the study. All times in this dataset are in UTC. Depths are in MD relative to Kelly Bushing Height, and temperatures are in degrees Fahrenheit. All DTS measurements were made using a Yokogawa 3000DTSX Distributed Temperature Sensing Interrogator Unit, with a spatial sampling interval of 3.28 feet and a temporal sampling rate of 129 seconds. The third-party Pressure-Temperature Gauge data should be used with caution after April 20, 2024, as its performance is not considered reliable beyond this date.

15 GEOTHERMAL ENERGY↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

Highly cascaded first-order fiber Bragg gratings in highly multimode optical fibers for distributed temperature sensing under harsh environment conditions

This study presents a pioneering technique for fabricating highly cascaded first-order fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method in highly multimode optical fibers, specifically Sapphire crystalline fiber, and pure silica coreless fiber. Notably, it marks the first successful demonstration of a distributed array comprising 10 FBGs within highly multimode fibers. This achievement is facilitated by a high-power laser technique that yields larger reflectors characterized by a Gaussian intensity profile. These first-order FBGs offer various advantages, including enhanced reflectivity, reduced fabrication time, and simplified spectral characteristics, enhancing their accessibility for interpretation when contrasted with higher-order FBGs. In addition to that it encompasses a comprehensive analysis of the robustness and efficacy of these FBGs, with particular emphasis on their ability to endure extreme temperatures. These FBGs demonstrate an advantageous capability for localized multi-point temperature monitoring, reaching temperatures up to 1500°C with sapphire crystalline fiber and 1100°C with pure silica coreless fiber. This resilience makes them suitable for deployment in harsh environmental conditions. This innovative approach substantially broadens the potential applications of highly multimode optical fibers, particularly in the arena of sensing and communication, where challenges related to thermal gradients and harsh environments prevail. Furthermore, these groundbreaking first-order FBGs signify a substantial advancement in the realm of distributed temperature sensing, offering supreme capabilities for temperature monitoring and signal stability. As such, our work holds the promise of a substantial impact on industries and applications that demand unwavering reliability under extreme conditions.

47 OTHER INSTRUMENTATION↗

Optical monitoring to detect contamination of power grid components

A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.

Mostafavi, Saman↗

Optical monitoring to detect contamination of power grid components

A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.

Mostafavi, Saman↗