Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution-level phasor measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution-Level Phasor Measurement Units Application to Composite Load Model Validation

The paper presents the results of composite load model validation based on the distribution level micro- phasor measurement units (PMU) measurements. The actual micro-PMU measurements from the distribution feeders are collected by Lawrence Berkley National Laboratory (LBNL). The composite load model parameters are initially generated using the load model data tool developed by Pacific Northwest National Laboratory (PNNL). The generated load models are calibrated to match the performances with the micro-PMU measurements using disturbance records “play-in” capabilities available in a GE PSLF simulation package. A trial-and-error approach based on engineering judgement is proposed in this paper to benchmark the generated load model parameters and is implemented in the prototype of load model validation tool, which would be a supplement to the load model data tool.

Liu, Yuan↗

Dynamic Performance Comparison and Prediction based on Distribution-level Phasor Measurement Units

This paper introduces a new distribution level Phasor Measurement Unit (PMU) which adopts advanced hardware components and structure. The hardware parameters from the new PMU and the existing PMU are used to build a simulation model to predict the PMU performance. Therefore, a real-world testbench is built and four distribution level PMUs are tested under the steady-state and dynamic tests. The quantitative experiment result confirms the prediction model which could guide future PMU design, and also verifies the accuracy of the new PMU on the synchrophasor and frequency measurements in multiple scenarios.

Wu, Yuru↗

Low cost, flexible, and distribution level universal grid analyser platform: designs and implementations

This study presents the designs and implementations of a distribution level open-universal grid analyser (Open-UGA) platform. The proposed Open-UGA platform consists of distribution-level phasor measurement units (PMUs), a standard signal generator, a router, and a server. Firstly, an overall introduction for the software, hardware, and server architectures of the Open-UGA platform is given. To give a detailed design, the software, hardware, server block diagrams, flowcharts, and printed circuit board photo of the Open-UGA platform are presented in detail. Then, four different types of distribution level PMU algorithms are introduced and implemented in the Open-UGA platform to verify the flexibility and reconfigurability. The flowcharts and functionalities of these four UGAs with different PMU algorithms are given as example implementations. Lastly, a performance comparison is conducted with both quantitative and illustrative results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locating the Source of Events in Power Distribution Systems Using Micro-PMU Data

A novel method is proposed to locate the source of events in power distribution systems by using distribution-level phasor measurement units, a.k.a., micro-PMUs. An event in this paper is defined rather broadly to include any major change in any component across the distribution feeder. The goal is to enhance situational awareness in distribution grid by keeping track of the operation (or misoperation) of various grid equipment, assets, distribution energy resources, loads, etc. The proposed method is built upon the compensation theorem in circuit theory to generate an equivalent circuit to represent the event by using voltage and current synchrophasors that are captured by micro-PMUs. Importantly, this method makes critical use of not only magnitude but also synchronized phase angle measurements, thus, it justifies the need to use micro-PMUs, as opposed to ordinary RMS-based voltage and current sensors. The proposed method can work with data from as a few as only two micro-PMUs. The effectiveness of the developed method is demonstrated through computer simulations on the IEEE 123-bus test system, and also on micro-PMUs measurements from a real-life 12.47 kV test feeder in Riverside, CA. In conclusion, the results verify that the proposed method is accurate and robust in locating the source of different types of events on power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Graph Laplacian Based Anomaly Detection for Spatiotemporal MicroPMU Data

This letter develops a novel anomaly detection method using the generalized graph Laplacian (GGL) matrix to visualize the spatiotemporal relationship of distribution-level phasor measurement unit (uPMU) data. The uPMU data in a specific time horizon is segregated into multiple segments. An optimization problem formulated as a Lagrangian function is utilized to estimate the GGL matrix. During the iterative process, an optimal update is constituted as a quadratic program (QP) problem. To perform the uPMU-based spatiotemporal analysis, normalized diagonal elements of GGL matrix are proposed as a quantitative metric. The effectiveness of the developed method is demonstrated through real-world uPMU measurements gathered from test feeders in Riverside, CA.

97 MATHEMATICS AND COMPUTING↗

Situational Awareness in Distribution Grid Using Micro-PMU Data: A Machine Learning Approach

The recent development of distribution-level phasor measurement units, a.k.a. micro-PMUs, has been an important step towards achieving situational awareness in power distribution networks. The challenge however is to transform the large amount of data that is generated by micro-PMUs to actionable information and then match the information to use cases with practical value to system operators. This open problem is addressed in this paper. First, we introduce a novel data-driven event detection technique to pick out valuable portion of data from extremely large raw micro-PMU data. Subsequently, a datadriven event classifier is developed to effectively classify power quality events. Importantly, we use field expert knowledge and utility records to conduct an extensive data-driven event labeling. Moreover, certain aspects from event detection analysis are adopted as additional features to be fed into the classifier model. In this regard, a multi-class support vector machine (multi-SVM) classifier is trained and tested over 15 days of real-world data from two micro-PMUs on a distribution feeder in Riverside, CA. In total, we analyze 1.2 billion measurement points, and 10,700 events. Here, the effectiveness of the developed event classifier is compared with prevalent multi-class classification methods, including k-nearest neighbor method as well as decision-tree method. Importantly, two real-world use-cases are presented for the proposed data analytics tools, including remote asset monitoring and distribution-level oscillation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UPS: Unified PMU-Data Storage System to Enhance T+D PMU Data Usability

The emerging distribution-level phasor measurement unit (D-PMU) is expected to play an important role in enhancing distribution system observability and situational-awareness. It is a demanding yet challenging task to develop advanced D-PMU data management and analytics tools to improve D-PMU data usability and further promote D-PMU projects deployment. This paper focuses on D-PMU data processing and storage. It presents a brief review of existing D-PMU data storage systems and points out their limitations on high-performance, flexibility, and scalability. To overcome the limitations, a unified PMU-data storage system (UPS) is proposed. Specifically, a unified I/O interface between storage servers and computing jobs is developed to effectively reduce the overhead of managing various computing jobs and data analytics over multiple storage infrastructures; and PMUCache with PMUCache partitioning and PMUCache replacement algorithms are designed to support in-situ data processing and shared distributed data storage and further serve the computing jobs/queries with different Quality of Service (QoS) requirements. Through a series of experiments, it is demonstrated that UPS achieves high performance on fast and big data processing and storage, and efficiently increases the flexibility and scalability of PMU data management systems.

42 ENGINEERING↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

Development of a High Resolution, Real Time, Distribution-Level Metering System and Associated Visualization, Modeling, and Data Analysis Functions

NREL is developing measurement devices and a supporting data collection network specifically targeted at electrical distribution systems to support research in this area. This paper describes the measurement network which is designed to apply real-time and high speed (sub-second) measurement principles to distribution systems that are already common for the transmission level in the form of phasor measurement units and related technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗