Search NASA⌕ Search

SEARCH · Search NASA

Results for “District heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of thermal energy storage for the proposed Twin Cities District Heating system

The technical and economic feasibility of incorporating thermal energy storage components into the proposed Twin Cities District heating project was evaluated. The technical status of the project is reviewed and conceptual designs of district heating systems with and without thermal energy storage were compared in terms of estimated capital requirements, fuel consumption, delivered energy cost, and environmental aspects. The thermal energy storage system is based on cogeneration and the storage of heat in aquifers.

Meyer, C. F.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Seasonal Thermal Energy Storage Program

The Seasonal Thermal Energy Storage (STES) Program designed to demonstrate the storage and retrieval of energy on a seasonal basis using heat or cold available from waste or other sources during a surplus period is described. Factors considered include reduction of peak period demand and electric utility load problems and establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The initial thrust of the STES Program toward utilization of ground water systems (aquifers) for thermal energy storage is emphasized.

Minor, J. E.↗

A comparison of economic evaluation models as applied to geothermal energy technology

Several cost estimation and financial cash flow models have been applied to a series of geothermal case studies. In order to draw conclusions about relative performance and applicability of these models to geothermal projects, the consistency of results was assessed. The model outputs of principal interest in this study were net present value, internal rate of return, or levelized breakeven price. The models used were VENVAL, a venture analysis model; the Geothermal Probabilistic Cost Model (GPC Model); the Alternative Power Systems Economic Analysis Model (APSEAM); the Geothermal Loan Guarantee Cash Flow Model (GCFM); and the GEOCOST and GEOCITY geothermal models. The case studies to which the models were applied include a geothermal reservoir at Heber, CA; a geothermal eletric power plant to be located at the Heber site; an alcohol fuels production facility to be built at Raft River, ID; and a direct-use, district heating system in Susanville, CA.

Ziman, G. M.↗

In-Service Monitoring of Steam Pipe Systems at High Temperatures

An effective, in-service health monitoring system is needed to track water condensation in real time through the walls of steam pipes. The system is required to measure the height of the condensed water from outside the pipe, while operating at temperatures that are as high as 250 C. The system needs to account for the effects of water flow and cavitation. In addition, it is desired that the system does not require perforating the pipes and thereby reducing the structural integrity. Generally, steam pipes are used as part of the district heating system carrying steam from central power stations under the streets to heat, cool, or supply power to high-rise buildings and businesses. This system uses ultrasonic waves in pulse-echo and acquires reflected signal data. Via autocorrelation, it determines the water height while eliminating the effect of noise and multiple reflections from the wall of the pipe. The system performs nondestructive monitoring through the walls of steam pipes, and automatically measures the height of condensed water while operating at the high-temperature conditions of 250 C. For this purpose, the ultrasonic pulse-echo method is used where the time-of-flight of the wave reflections inside the water are measured, and it is multiplied by the wave velocity to determine the height. The pulse-echo test consists of emitting ultrasonic wave pulses from a piezoelectric transducer and receiving the reflections from the top and bottom of the condensed water. A single transducer is used as a transmitter as well as the receiver of the ultrasonic waves. To obtain high resolution, a broadband transducer is used and the frequency can be in the range of 2.25 to 10 MHz, providing sharp pulses in the time domain allowing for higher resolution in identifying the individual reflections.

Bar-Cohen, Yoseph↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Hot-spot heating in central-station arrays

Hot spot tests performed on the Sacramento Municipal Utility District (SMUD) verificaton array show that current imbalance occurs, resulting in significant hot spot heating. One cause of current imbalance is differences in the average shunt resistances of parallel cell strings due to cell shunt resistance variations. In depth hot spot tests are performed on the verification array with bypass diodes. The tests had several objectives: (1) a comparison of hot spot temperatures achieved under field conditions with those obtained with the present laboratory hot spot test using similar modules; (2) an assessment of current imbalance versus cross tie frequency; and (3) an assessment of different shadow patterns and shadow densities. Instrumented modules are used to vary the number of cross ties and to measure the test-cell current and back-bias voltage. The widths, lengths, and densities of the shadows are varied to maximize the back bias voltage at maximum power current. An infrared camera is used to indicate the existence of hot spots and estimate temperature increases in conjunction with thermocouples. The results of these hot spot tests indicate a sensitivity of back bias heating to the shadow size (amount of cell coverage) and density.

Gonzalez, C. C.↗

A GIS approach to urban heat island research: The case of Huntsville, Alabama

The urban heat island represents a case of inadvertent human modification of climate in an urban environment. Urbanization changes the nature of the surface and atmospheric properties of a region. As a result, radiation balance in the urban areas is altered and sensible heat is added to the point that urban areas are warmer than surrounding rural areas. At the boundary between the rural and urban area, a sharp rise in temperature occurs, culminating to a peak temperature at the central business district of the city, hence the name 'urban heat island'. The extent and intensity of the urban heat island are a function of population size, land use, and topography. Because the urban heat island exhibits spatial variations of temperatures, the use of Geographic Information System (GIS) is appropriate. The research on the urban heat island focuses on the acquisition of 15 bands of visible and thermal infrared data (ranging from 0.45 to 12.2 microns) from an aerial platform using NASA's ATLAS (Airborne Thermal/Visible Land Application Sensor) over Huntsville, Alabama. The research reported in this paper is an analysis of the impact of population, land use, and topography on the shape of the urban heat island that could be developed in Huntsville using the GIS approach. The outcome of this analysis can then be verified using the acquired remotely sensed data.

Lo, Chor Pong↗

A technical analysis for cogeneration systems with potential applications in twelve California industrial plants

In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass

Moretti, V. C.↗

Land Use and Land Cover Change, Urban Heat Island Phenomenon, and Health Implications: A Remote Sensing Approach

Land use and land cover maps of Atlanta Metropolitan Area in Georgia were produced from Landsat MSS and TM images for 1973,1979,1983,1987,1992, and 1997, spanning a period of 25 years. Dramatic changes in land use and land cover have occurred with loss of forest and cropland to urban use. In particular, low-density urban use, which includes largely residential use, has increased by over 119% between 1973 and 1997. These land use and land cover changes have drastically altered the land surface characteristics. An analysis of Landsat images revealed an increase in surface temperature and a decline in NDVI from 1973 to 1997. These changes have forced the development of a significant urban heat island effect and an increase in ground level ozone production to such an extent, that Atlanta has violated EPA's ozone level standard in recent years. The urban heat island initiated precipitation events that were identified between 1996 and 2000 tended to occur near high-density urban areas but outside the I-285 loop that traverses around the Central Business District, i.e. not in the inner city area, but some in close proximity to the highways. The health implications were investigated by comparing the spatial patterns of volatile organic compounds (VOC) and nitrogen oxides (NOx) emissions, the two ingredients that form ozone by reacting with sunlight, with those of rates of cardiovascular and chronic lower respiratory diseases. A clear core-periphery pattern was revealed for both VOC and NOx emissions, but the spatial pattern was more random in the cases of rates of cardiovascular and chronic lower respiratory diseases. Clearly, factors other than ozone pollution were involved in explaining the rates of these diseases. Further research is therefore needed to understand the health geography and its relationship to land use and land cover change as well as urban heat island effect. This paper illustrates the usefulness of a remote sensing approach for this purpose.

Lo, C. P.↗

The Past and Future Changes in Climate of the Rice-Wheat Cropping Zone in Punjab, Pakistan

Agriculture is ranked top among Pakistan economic sectors vulnerable to the potential impacts of climate change. The agricultural production system is directly affected by weather inputs (temperature, solar radiation, and rainfall) that are projected to change in future (following increases in carbon dioxide and other greenhouse gasses). Although Climatic extremes such as drought, floods and heat waves, are expected to increase with detrimental consequences for agriculture and livestock production, yet changes in mean climates also pose challenges to sustainable development. This study presents climate change results for five districts within the major rice-wheat productivity zone of Punjab province in Pakistan. The results are focused on RCP8.5 mid-century (2040-2069) scenarios derived from five global climate models (GCMs) output and the Kharif (June-October) and Rabi (November-April) seasons. Analysis of recent historical weather data of Sialkot and Sheikhupura districts shows an increase in minimum temperatures and maximum temperatures and a large variation in rainfall. This temperature change and variability in rainfall are expected to enhance further as we approach 2050s. The mean maximum temperature is projected to increase by 2-2.5 ºC during the rice growing (Kharif) season and 2.4-2.7ºC during the wheat growing (Rabi) season. Rainfall during the rice growing season is more uncertain, with projections indicating an increase of 25%-35 % in the study region, while a minimal change is expected during the Rabi season. Climax of the rice growing season corresponds with the projected increase in monsoon intensity, leaving no doubt about the crop water demand satisfaction. However, a simultaneous increase in the day and night temperature may affect the growth and development of some critical phenological stages and thus could impact final yield.

Climate Change↗

Remote estimation of surface moisture over a watershed

The author has identified the following significant results. Contoured analyses of moisture availability, moisture flux, sensible heat flux, thermal inertia, and day and nighttime temperatures over a Missouri watershed for a date in June and in September show that forests and creeks exhibit the highest values of moisture availability, whereas farmlands and villages are relatively dry. The distribution of moisture availability over agricultural districts differs significantly between the two cases. This difference is attributed to a change in the surface's vegetative canopy between June and September, with higher moisture availabilities found in the latter case. Horizontal variations of moisture, however, do indicate some relationship between moisture availability and both local rainfall accumulations and the nature of the terrain.

Kocin, P. J.↗

Contribution to the Study of Regional Magnetization of Satellite Magnetic Measurement: Magsat, Orsted, and Champ (with Gravity Field)

A discussion of and introduction to satellite-altitude geopotential field studies and their interpretation with emphasis on results from metalliferous regions will be given. The magnetic and gravimetric measurements from satellite altitudes show heterogeneity in deeper parts of the lithosphere. These patterns of magnetic anomalies do not only reveal the largest iron ore deposits such as Kiruna, Sweden, Kursk, Russia, and Banugi, Central African Republic but also linear features indicating structural discontinuities. Changes of magnetic amplitude of these patterns are caused by intersecting transverse fractures localizing magmatism and concentration of metals. In addition satellite altitude data are related to variations in crustal thickness and heat flow. Deep-rooted structural discontinuities, defined by combination of geological and geophysical criteria, with spacing of several hundred kilometers, reveal a quite uniform pattern in the deeper parts of the lithosphere. As these structures provide favorable pathways for the ascent of heat, magmas and ore-forming fluids, their recognition is of crucial importance and can be used in the compilation of a new type of mineral prognosis map. An example from Europe includes a pattern of east west trending structural discontinuities or belts and their junction with the NW-trending Tornqvist-Teisseyre Line. The Upper Silesian-Cracovian Zn-Pb district occurs along one of the latitudinal belts. Leslaw Teper of the University of Silesia has been invited to show the fractures in crystalline basement beneath the sediments hosting the Zn-Pb ores.

Taylor, Patrick T.↗

Proceedings of the Alternate Energy Systems Seminar

The Alternative Energy Systems Seminar was held on March 30, 1978, and was sponsored jointly be the Southwest District Office of the U.S. Department of Energy and JPL. The seminar was an experiment in information exchange with the aim of presenting, in a single day, status and prospects for a number of advanced energy systems to a diverse, largely nontechnical audience, and to solicit post-seminar responses from that audience as to the seminar's usefulness. The major systems presented are: (1) Solar Photovoltaic; (2) Geothermal; (3) Cogeneration Power; (4) Solar Thermal; (5) Solar Heating and Cooling; (6) Wind Energy; and (7) Systems Considerations.

Source record↗

Deep Structure of the Earth and Concentration of Metals in the Lithosphere: A Geodynamic Approach

A discussion of and introduction to satellite-altitude geopotential fields studies and their interpretation with emphasis on results from metalliferous regions will be given. The magnetic and gravimetric measurements from satellite altitudes show heterogeneity in deeper parts of the lithosphere. These patterns of magnetic anomalies do not only reveal the largest iron ore deposits such as Kiruna, Sweden and Kursk, Russia, but also linear features indicating structural discontinuities. Changes of magnetic amplitude of these patterns are caused by intersecting transverse fractures localizing magmatism and concentration of metals. The role of trans-regional mantle-rooted structural discontinuities in the concentration of metals will be discussed and a new type of mineral prognosis map will be presented. Deep-rooted structural discontinuities, defined by combination of geological and geophysical criteria, with spacing of several hundred kilometers, reveal a quite uniform pattern in the deeper parts of the lithosphere. As these structures provide favorable pathways for the ascent of heat, magmas and ore-forming fluids, their recognition is of crucial importance and can be used in the compilation of a new type of mineral prognosis map. Examples are shown from the United States, Canada, China, Burma, South America, Europe and Australia. The European example includes a pattern of east west trending structural discontinuities or belts and their junction with the NW-trending Tornqvist-Teisseyre Line. The Upper Silesian-Cracovian Zn-Pb district occurs along one of the latitudinal belts. Leslaw Teper of the University of Silesia has been invited to show the fractures in crystalline basement beneath the sediments hosting the Zn-Pb ores.

Taylor, Patrick T.↗

A Downscaling Analysis of the Urban Influence on Rainfall: TRMM Satellite Component AMS Conference on Satellite Meteorology and Oceanography

A recent publication by Shepherd et al. (2002) demonstrated the feasibility of using TRMM precipitation radar (PR) estimates to identify precipitation anomalies caused by urbanization. The approach is particularly useful for investigating this global process because TRMM data span large portions of the globe and comprise an extended temporal dataset. Recent literature suggests that urbanized regions of Houston, Texas may be influencing lightning and precipitation formation over and downwind of the city. Possible mechanisms include: (1) enhanced convergence through interactions between the sea breeze, Galveston bay breeze, and urban heat island circulations, (2) enhanced convergence due to increased surface roughness over the city and/or destabilization of the boundary layer by the UHI, or (3) enhanced cloud condensation nuclei due to urban and industrial aerosol sources. In this study, a downscaling analysis of spatial and temporal trends in rainfall around the Houston Area is being conducted. The downscaling analysis concept involves identifying and quantifying urban rainfall anomalies at progressively smaller spatial and temporal scales using the TRMM satellite, ground-based radar, and a dense network of rain gauges. The goal is to test the hypothesis that the Houston urban district and regions in the climatological downwind region of the city exhibit enhanced rainfall amounts relative to the climatological upwind regions. TRMM was launched in 1997 and currently operates in a low-inclination (35 deg), non-sun-synchronous orbit at an altitude of 402 km (350 km prior to August 2001). The satellite analysis follows the methodologies described in Shepherd et al. (2002). Nearly five years of TRMM PR-derived mean monthly rainfall estimates are utilized to produce annual and warm season isohyetal analyses around Houston. Early results indicate that rainfall rates (mm/h) for the entire period are largest within 100 km northeast and east of Houston (e.g. the "hypothesized downwind region"). The mean rainfall rate over the Houston urban center is 30.5% larger than the upwind control region. The mean rainfall rate in the downwind region is 34.4% larger than the upwind region. An analysis of a parameter called the urban rainfall ratio (URR) illustrates that 65% (88%) of the satellite-derived rainfall rates in the downwind (upwind control) region are greater (less) than the mean background rainfall rate of the entire study region. When the data is stratified by summer months from 1998 to 2001 (June-August), even greater influence over and downwind of the urban area is observed in the statistics. This result is consistent with published reports of urban-generated rainfall being more prevalent in the warm season. The research demonstrates that the evolving TRMM satellite climatology is a credible way to detect mesoscale precipitation signatures that may be linked to urbanization. Early results also corroborate recent findings on Houston-induced convection/drainfall anomalies. Burian and Shepherd will report on other aspects of the downscaling analysis in future forums, but early rain gauge results are consistent with the satellite-based observations.

Shepherd, J. Marshall↗