Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design package for solar domestic hot water system

The initial design of a solar domestic hot water system is considered. The system performance specification and detailed design drawings are included. The hot water systems consist of the following subsystems: collector, storage, control, transport, auxiliary energy, and government-furnished site data acquisition. The two systems are installed at Tempe, Arizona, and San Diego, California.

Source record↗

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

Source record↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

An economic and performance design study of solar preheaters for domestic hot water heaters in North Carolina

The performance and estimated material costs for several solar preheaters for domestic hot water heaters using isolation levels present in North Carolina are presented. The effects of monthly variations in isolation and the direction of incident radiation are included. Demand is assumed at 13 gallons (49.2 liters) per day per person. The study shows that a closed circulation system with 82 gallons (310 liters) of preheated storage and 53.4 cu ft (4.94 cu m) of collector surface with single cover can be expected to cost about $800 and to repay it capital cost and interest (at 8%) in 5.2 years, assuming present electric rates increase at 5% per year.

Jones, C. B.↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Solar heating and domestic hot water system installed at North Dallas High School

The solar energy system located at the North Dallas High School, Dallas, Texas is discussed. The system is designed as a retrofit in a three story with basement, concrete frame high school building. Extracts from the site files, specification references for solar modification to existing building heating and domestic hot water systems, drawings, installation, operation and maintenance instructions are included.

Source record↗

Prototype solar domestic hot water systems

Construction of a double wall heat exchanger using soft copper tube coiled around a hot water storage tank was completed and preliminary tests were conducted. Solar transport water to tank potable water heat exchange tests were performed with a specially constructed test stand. Work was done to improve the component hardware and system design for the solar water heater. The installation of both a direct feed system and a double wall heat exchanger system provided experience and site data to enable informative decisions to be made as the solar market expands into areas where freeze protection is required.

Source record↗

System design package for IBM system one: solar heating and domestic hot water

This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage. The system was designed for installation into a single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system was packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

Preliminary design package for Sunspot Domestic Hot Water Heating System

The design review includes a drawing list, auto-control logic, measurement definitions, and other document pertaining to the solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control transport, auxiliary energy, and site data acquisition.

Source record↗

System Design Package for SIMS Prototype System 3, Solar Heating and Domestic Hot Water

A collation of documents and drawings are presented that describe a prototype solar heating and hot water system using liquid flat plate collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

System design package for SIMS prototype system 4, solar heating and domestic hot water

The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

Source record↗

Solar domestic hot water system installed at Texas City, Texas

This is the final technical report of the solar energy system located at LaQuinta Motor Inn, Texas City, Texas. The system was designed to supply 63 percent of the total hot water load for a new 98 unit motor inn. The solar energy system consists of a 2100 square feet Raypack liquid flat plate collector subsystem and a 2500 gallon storage subsystem circulating hot water producing 3.67 x 10 to the 8th power Btu/year. Abstracts from the site files, specification references, drawings, installation, operation, and maintenance instructions are included.

Source record↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.