Doppler broadening effect on collision cross section functions - Deconvolution of the thermal averaging

The surprising feature of the Doppler problem in threshold determination is the 'amplification effect' of the target's thermal energy spread. The small thermal energy spread of the target molecules results in a large dispersion in relative kinetic energy. The Doppler broadening effect in connection with thermal energy beam experiments is discussed, and a procedure is recommended for the deconvolution of molecular scattering cross-section functions whose dominant dependence upon relative velocity is approximately that of the standard low-energy form.

Bernstein, R. B.↗

Correction of Doppler-broadened Rayleigh backscattering effects in H2O dial measurements

A general method of solutions for treating effects of Doppler-broadened Rayleigh backscattering in H2O Differential Absorption Lidar (DIAL) measurements are described and discussed. Errors in vertical DIAL measuremtns caused by this laser line broadening effect can be very large and, therfore, this effect has to be accounted for accurately. To analyze and correct effects of Doppler-broadened Rayleigh backscattering in DIAL experiments, a generalized DIAL approximation was derived starting from a lidar equation, which includes Doppler broadening. To evaluate the accuracy of H2O DIAL measurements, computer simulations were performed. It was concluded that correction of Doppler broadened Rayleigh backscattering is possible with good accuracy in most cases of tropospheric H2O DIAL measurements, but great care has to be taken when layers with steep gradients of Mie backscattering like clouds or inversion layers are present.

Ansmann, A.↗

Doppler Broadening and Other Temperature Effects

In this paper I attempt to document what I have learned and still remember about temperature effects, particularly Doppler broadening, on nuclear data, as it applies to ENDF formatted data. My focus is on the SIGMA1 method of Doppler broadening that I developed over 50 years ago. However, I do realize that there are currently many different methods used in computer codes, and I have tried to keep my discussion general as it applies to ALL of these methods. In particular, ALL of the MYTHS I describe below apply to all Doppler broadening methods: they all solve the parabolic diffusion equation in spherical geometry in (speed, reaction rate) versus temperature. These methods differ only in how the cross section is represented. So, at 85 years old here is what I still remember.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theoretical studies of lasers and converters

Discussed here is Doppler broadening and its effects upon the stimulated emission cross-section connecting an upper level with a lower level in an iodine laser. The stimulated emission cross section is given. The level transitions for the iodine laser are illustrated as are the relative intensities of these transitions. Also discussed is the Voigt profile, which considers the effect of both Doppler broadening and collision broadening upon the absorption line shape. The equations describing the Voigt profile were added to the continuous flow laser model laser simulation program. The results were compared with the standard absorption profile reported in an earlier study. There seems to be no advantage to using the Voigt profile as the laser power output is relatively insensitive to changes in the absorption cross section at the pressures being considered for a space laser. One disadvantage of using the Voigt profile is the excessive numerical computations required by the additional equations.

Heinbockel, John H.↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Laser-induced line-narrowing effects in coupled Doppler-broadened transitions. II - Standing-wave features.

Previous theoretical results on the influence of a laser on the line shape of a coupled transition (laser-induced line narrowing) have been restricted to the case where the laser is detuned from the center of its atomic gain profile or is in the form of a traveling wave. The present paper extends these results to the case where the laser is an intense standing-wave field tunable to the center of its atomic gain profile (conditions for Lamb dip). A theoretical solution of the problem is developed, and a detailed discussion of line shapes and physical processes involved is included.

Feldman, B. J.↗

Abundances in late-type giants.

The narrow-band photometry of Spinrad and Taylor (1969) is analyzed by the synthetic spectra technique. Surface gravities, Doppler broadening velocities, effective temperatures, and metal abundances are determined for 131 K giants. Evolutionary tracks and gravities determined from the photometry are used to give space positions, space velocities, and absolute magnitudes of the 131 stars. We conclude that a class of stars exists with metals and/or nitrogen significantly enhanced with respect to the sun; further that these stars have average space motions similar to those of moderately old Population I stars. The Doppler broadening velocity is found to be a strong function of temperature for K giants, and in some cases, possibly a function of surface gravity.

Gottlieb, D. M.↗

The Primary Interaction Compton Couple algorithm for sorting GRETINA/GRETA interaction points

The Primary Interaction Compton Couple (PICC) algorithm is presented in this work. The algorithm is used to determine the first-interaction-point position for $γ$-ray events in GRETINA. The first-interaction-point position is crucial for in-beam $γ$-ray spectroscopy experiments with fast beams due to the effect of Doppler broadening on the in-beam energy resolution. The development of the algorithm and its performance compared to a tracking algorithm and the Main Interaction assumption is presented. The PICC algorithm is demonstrated with real data to outperform the $γ$-ray energy tracking algorithm used for comparison here and the Main Interaction assumption in first-interaction-point determinations.

GRETINA↗

Correlation effects in the theory of combined Doppler and pressure broadening. I - Classical theory

An investigation is conducted of the combined effects of radiator-perturber collisions and radiator translational motion in the context of foreign gas broadening of optical transitions in neutral radiators. Questions concerning the speed-dependent collision frequency are considered and aspects of general theory are explored, taking into account the correlation function, the ensemble average, and the kinetic equation formalism. An elementary solution is discussed along with a one-perturber approximation, inverse power law model calculations, and a comparison with the Voigt profile.

Ward, J.↗

Correct Interpretations of ENDF-102 Definitions for Resonance Effects

My Uncle Willie circa 1600 wrote “What’s in a name; a rose by any other name would smell as sweet.” I fear in this case we have a somewhat similar problem in that we may be using the same word but are not using the same definition; specifically, the word Unresolved. The simplest physics definition as it applies to neutron resonances, is the energy point where we can no longer see/measure ALL – let me repeat that – ALL - of the individual resonances. That seems simple and clear, but the question is: how to represent resonances beyond this point in order to accurately reproduce the effects we have seen in measurements and expect/need to reproduce in our applications. We know there are more, unseen resonances, otherwise we wouldn’t say Unresolved. The ENDF approach is well defined in ENDF-102 and simple: for ENDF data the only way to represent Unresolved data is by using a theoretical model to define the distribution of resonances, including those that are too narrow to measure (i.e., are unresolved). It is important to note that in ENDF this is the one and only Unresolved model, e.g., there is no provision in ENDF to accurately define individually ALL resonances above the Resolved energy range – by ALL here I mean both those that we can measure and those that we cannot individually measure, but that theory and integral measurements tells us are present. An alternative approach, which would appear to be equally valid, would be to include the latest measured data as tabulated energy expendent data extending upwards in energy above the Resolved energy range. In this approach the evaluation would not include an ENDF style Unresolved energy range; it would only include a Resolved resonance region, followed by tabulated higher energy points, representing the resonances that could be measured beyond the Resolved range. But an important point to note: By listing these resonances above the resolved energy one admits that at least some resonances in this energy range are missing as Unresolved; i.e., they are too narrow or overlapping to measure. The purpose of this paper is to illustrate that the later approach, while done with good intentions, and appearing to be valid/adequate in plots, does not meet the need of our engineering applications. Why? As we will see below, of these two possible approaches, only the ENDF use of a model to statistically include the missing, i.e., unresolved, resonances, can meet our engineering needs to reproduce the integral effects we have measured and understand. Only with this statistical model can we predict and include in our calculated results the important effects of temperature (Doppler broadening), and energy integrals (self-shielding). Below I will first present results using two ENDF/B-VIII.1 evaluations, U235 and U238, that use the correct ENDF-102 definition of an Unresolved resonance region, using a statistical model to include the effects of resonances that theory predicts are present, but are too narrow to measure. These two evaluations reproduce the expected temperature (Doppler) and energy integral (self-shielding) effects that we expect. Next I will present results using one ENDF/B-VIII.1 evaluation, 26-Fe-56, that does not use an ENDF-102 Unresolved resonance region; instead above its Resolved energy range it lists many tabulated energy points, that look like measured data, but by definition, since they are included above the ENDF Resolved energy range there are missing Unresolved resonances, i.e., there are missing the resonances that are too narrow to resolve, i.e., are unresolved. My conclusion, and I hope yours, is that the below figures illustrate that this approach does not reproduce the temperature and energy integrals that we expect and need to accurately calculate results for our fission reactor calculations. As such this approach should not be used in ENDF formatted evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser amplification of incoherent radiation

The amplification of noise in a laser amplifier is treated theoretically. The model for the active medium and its description using density-matrix techniques, are taken from the theory of laser operation. The spectral behavior of the radiation in the nonlinear regime is studied and the formalism is written from the onset in the frequency domain. The statistics of the light are gradually modified by the nonlinear amplification process, and expressions are derived for the rate of change of fluctuations in intensity as a measure of statistical changes. In addition, the range of validity of Litvak's Gaussian-statistics approximation is discussed. In the homogeneous-broadening case, the evolution of initially broadband Gaussian radiation toward quasimonochromatic oscillations with laserlike statistics is explored in several numerical examples. The connections of this study with the time-domain work on self-pulsing in a ring-laser configuration, are established. Finally, spectral-narrowing and -rebroadening effects in Doppler-broadened media are discussed both analytically and with numerical examples. These examples show the distinct contribution of pulsations in the population ('Raman-type terms'), and saturation phenomena.

Menegozzi, L. N.↗

Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial-off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy so long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C and 1 atm). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0-10.2 PSIA) or spacesuit (4.1-8.0 PSIA), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the basis of the exponential loss in accuracy is developed theoretically considering thermal, Doppler, and Lorentz broadening effects which arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. As a result, this manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application.

Swickrath, Michael J.↗

Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy as long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C (70.0 F) and 1 atmosphere). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0{10.2 pounds per square inch absolute (psia)) or spacesuit (4.1{8.0 psia), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the source of the exponential loss in accuracy is developed theoretically. The basis of the loss can be explained through thermal, Doppler, and Lorentz broadening effects that arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. This manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application.

Swickrath, Michael J.↗

Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Carbon dioxide produced through respiration can accumulate rapidly within closed spaces. If not managed, a crew's respiratory rate increases, headaches and hyperventilation occur, vision and hearing are affected, and cognitive abilities decrease. Consequently, development continues on a number of CO2 removal technologies for human spacecraft and spacesuits. Terrestrially, technology development requires precise performance characterization to qualify promising air revitalization equipment. On-orbit, instrumentation is required to identify and eliminate unsafe conditions. This necessitates accurate in situ CO2 detection. Recursive compensation algorithms were developed for sub-ambient detection of CO2 with commercial off-the-shelf (COTS) non-dispersive infrared (NDIR) sensors. In addition, the source of the exponential loss in accuracy is developed theoretically. The basis of the loss can be explained through thermal, Doppler, and Lorentz broadening effects that arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. The objective was to develop a mathematical routine to compensate COTS CO2 sensors relying on NDIR over pressures, temperatures, and compositions far from calibration conditions. The routine relies on a power-law relationship for the pressure dependency of the sensors along with an equivalent pressure to account for the composition dependency. A Newton-Raphson iterative technique solves for actual carbon dioxide concentration based on the reported concentration. Moreover, first principles routines were established to predict mixed-gas spectra based on sensor specifications (e.g., optical path length). The first principles model can be used to parametrically optimize sensors or sensor arrays across a wide variety of pressures/temperatures/ compositions. In this work, heuristic scaling arguments were utilized to develop reasonable compensation techniques. Experimental results confirmed this approach and provided evidence that composition broadening significantly alters spectra when pressure is reduced. Consequently, a recursive compensation technique was developed with the Newton-Raphson method, which was subsequently verified through experimentation.

Swickrath, Michael J.↗

Deconvolution of diode-laser spectra

A new technique has been developed for deconvolving diode-laser spectra. This technique treats Doppler broadening, collisional broadening, and instrumental effects simultaneously. This technique is superior to previous deconvolution methods in the recovery of line-strength and transition-frequency information. A section of the ethane spectrum near 12 microns is used as an example. This new approach applies to any spectroscopy in which the instrumental resolution is narrower than actual linewidths.

Halsey, G. W.↗