Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler broadening effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Doppler Broadening and Other Temperature Effects

In this paper I attempt to document what I have learned and still remember about temperature effects, particularly Doppler broadening, on nuclear data, as it applies to ENDF formatted data. My focus is on the SIGMA1 method of Doppler broadening that I developed over 50 years ago. However, I do realize that there are currently many different methods used in computer codes, and I have tried to keep my discussion general as it applies to ALL of these methods. In particular, ALL of the MYTHS I describe below apply to all Doppler broadening methods: they all solve the parabolic diffusion equation in spherical geometry in (speed, reaction rate) versus temperature. These methods differ only in how the cross section is represented. So, at 85 years old here is what I still remember.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

The Primary Interaction Compton Couple algorithm for sorting GRETINA/GRETA interaction points

The Primary Interaction Compton Couple (PICC) algorithm is presented in this work. The algorithm is used to determine the first-interaction-point position for $γ$-ray events in GRETINA. The first-interaction-point position is crucial for in-beam $γ$-ray spectroscopy experiments with fast beams due to the effect of Doppler broadening on the in-beam energy resolution. The development of the algorithm and its performance compared to a tracking algorithm and the Main Interaction assumption is presented. The PICC algorithm is demonstrated with real data to outperform the $γ$-ray energy tracking algorithm used for comparison here and the Main Interaction assumption in first-interaction-point determinations.

GRETINA↗

Correct Interpretations of ENDF-102 Definitions for Resonance Effects

My Uncle Willie circa 1600 wrote “What’s in a name; a rose by any other name would smell as sweet.” I fear in this case we have a somewhat similar problem in that we may be using the same word but are not using the same definition; specifically, the word Unresolved. The simplest physics definition as it applies to neutron resonances, is the energy point where we can no longer see/measure ALL – let me repeat that – ALL - of the individual resonances. That seems simple and clear, but the question is: how to represent resonances beyond this point in order to accurately reproduce the effects we have seen in measurements and expect/need to reproduce in our applications. We know there are more, unseen resonances, otherwise we wouldn’t say Unresolved. The ENDF approach is well defined in ENDF-102 and simple: for ENDF data the only way to represent Unresolved data is by using a theoretical model to define the distribution of resonances, including those that are too narrow to measure (i.e., are unresolved). It is important to note that in ENDF this is the one and only Unresolved model, e.g., there is no provision in ENDF to accurately define individually ALL resonances above the Resolved energy range – by ALL here I mean both those that we can measure and those that we cannot individually measure, but that theory and integral measurements tells us are present. An alternative approach, which would appear to be equally valid, would be to include the latest measured data as tabulated energy expendent data extending upwards in energy above the Resolved energy range. In this approach the evaluation would not include an ENDF style Unresolved energy range; it would only include a Resolved resonance region, followed by tabulated higher energy points, representing the resonances that could be measured beyond the Resolved range. But an important point to note: By listing these resonances above the resolved energy one admits that at least some resonances in this energy range are missing as Unresolved; i.e., they are too narrow or overlapping to measure. The purpose of this paper is to illustrate that the later approach, while done with good intentions, and appearing to be valid/adequate in plots, does not meet the need of our engineering applications. Why? As we will see below, of these two possible approaches, only the ENDF use of a model to statistically include the missing, i.e., unresolved, resonances, can meet our engineering needs to reproduce the integral effects we have measured and understand. Only with this statistical model can we predict and include in our calculated results the important effects of temperature (Doppler broadening), and energy integrals (self-shielding). Below I will first present results using two ENDF/B-VIII.1 evaluations, U235 and U238, that use the correct ENDF-102 definition of an Unresolved resonance region, using a statistical model to include the effects of resonances that theory predicts are present, but are too narrow to measure. These two evaluations reproduce the expected temperature (Doppler) and energy integral (self-shielding) effects that we expect. Next I will present results using one ENDF/B-VIII.1 evaluation, 26-Fe-56, that does not use an ENDF-102 Unresolved resonance region; instead above its Resolved energy range it lists many tabulated energy points, that look like measured data, but by definition, since they are included above the ENDF Resolved energy range there are missing Unresolved resonances, i.e., there are missing the resonances that are too narrow to resolve, i.e., are unresolved. My conclusion, and I hope yours, is that the below figures illustrate that this approach does not reproduce the temperature and energy integrals that we expect and need to accurately calculate results for our fission reactor calculations. As such this approach should not be used in ENDF formatted evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient Computation of Doppler-Broadened Elastic Scattering Kernel Moments Using Ladder-Operator Formulation

Anefficient routine for computing Legendre moments of the Doppler-broadened elastic scattering kernel, including resonance scattering effects, has been implemented in the ISOXML module of Griffin. Isotropic scattering in the center-of-mass system and the ideal gas model for target motion are assumed. A ladder-operator formulation is introduced to compute all Legendre moments from order 0 to N simultaneously, enabling near-linear scaling of computational cost with respect to the maximum Legendre order. A physics-based strategy for constructing outgoing energy grids has also been developed, in which a tailored base grid is combined with adaptive refinement to maintain accuracy while limiting the number of outgoing energy points. For energies between resonances, a constant cross-section model is employed to further reduce computational cost. In addition, a quantitative criterion is derived to determine isotope-wise cut-off incident energies based on a prescribed up-scattering probability coverage. For 238U, up to incident energies of approximately 75, 230, and 661 eV at 294, 900, and 2500 K (corresponding to a 2% up-scattering probability threshold), computation of P0 kernels requires 1–8 s and computation of P0–P5 kernels requires 0.4–4 min using a single thread, while maintaining 1–3% relative error in up-scattering probability. These results demonstrate that the proposed formulation enables accurate and computationally practical Doppler-broadened kernel generation for online multigroup cross-section production in Griffin.

Doppler-broadening↗

Thermomechanics coupling to Monte Carlo particle transport on unstructured mesh geometries using Cardinal

Geometry deformation due to thermal expansion influences neutron transport in many systems. Studying this phenomenon involves coupling models for neutronics, thermal hydraulics, and solid mechanics. To enable high fidelity modeling of these coupled physics, new capabilities were introduced in Cardinal, coupling OpenMC Monte Carlo particle transport models with MOOSE thermomechanical physics on unstructured moving-mesh geometries. In this work, we present a fully open-source capability leveraging on-the-fly mesh skinning to automatically regenerate OpenMC geometry, which allows multiphysics feedback from temperature, density, and geometry changes. The new capability is verified using an analytic benchmark slab problem, which couples S 2 neutron transport with thermal conduction, convective boundary conditions, Doppler-broadened cross sections, and nonlinear thermal expansion effects along the heated slab. Cardinal reproduces the analytic solutions for the neutron flux, heating, k eff , and temperature with demonstrated convergence in various error terms including mesh resolution and cross section temperature library spacing. For the nominal benchmark conditions and with a fine mesh, maximum relative errors for neutron flux, temperature, and heating are lower than 1%, while errors in integral quantities such as k eff and slab length are within 1 pcm and 48 µm, respectively. This work (i) presents a new numerical approach to thermomechanics coupling with OpenMC models, (ii) is the first (to our knowledge) to utilize a mechanical partial differential equation (PDE) solution to solve the (Griesheimer and Kooreman, 2022) analytic benchmark, and (iii) develops this verified capability within an open-source package.

97 - MATHEMATICS AND COMPUTING↗

The XRISM first-light observation: Velocity structure and thermal properties of the supernova remnant N 132D

Abstract We present an initial analysis of the X-Ray Imaging and Spectroscopy Mission (XRISM) first-light observation of the supernova remnant (SNR) N 132D in the Large Magellanic Cloud. The Resolve microcalorimeter has obtained the first high-resolution spectrum in the 1.6–10 keV band, which contains K-shell emission lines of Si, S, Ar, Ca, and Fe. We find that the Si and S lines are relatively narrow, with a broadening represented by a Gaussian-like velocity dispersion of $\sigma _v \sim 450$ km s$^{-1}$. However, the Fe He$\alpha$ lines are substantially broadened with $\sigma _v \sim 1670$ km s$^{-1}$. This broadening can be explained by a combination of the thermal Doppler effect due to the high ion temperature and the kinematic Doppler effect due to the SNR expansion. Assuming that the Fe He$\alpha$ emission originates predominantly from the supernova ejecta, we estimate the reverse shock velocity at the time when the bulk of the Fe ejecta were shock heated to be $-1000 \lesssim V_{\rm rs}$ (km s$^{-1}$) $\lesssim 3300$ (in the observer frame). We also find that Fe Ly$\alpha$ emission is redshifted with a bulk velocity of $\sim 890$ km s$^{-1}$, substantially larger than the radial velocity of the local interstellar medium surrounding N 132D. These results demonstrate that high-resolution X-ray spectroscopy is capable of providing constraints on the evolutionary stage, geometry, and velocity distribution of SNRs.

individual objects↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

Feasibility of main thermal ion heating by ICRF waves using a top launcher in a tokamak with deuterium–tritium plasmas

A scenario of ion cyclotron range of frequency (ICRF) wave injection from a top launcher is proposed as an efficient and direct heating method for thermal deuterium ions in deuterium–tritium tokamak plasmas. Positioned between the tritium cyclotron layer and ion–ion hybrid layer, the top launcher allows effective wave penetration to the ion–ion hybrid layer and enables significant power transfer to thermal deuterium. This is achieved through favorable wave polarization for fundamental cyclotron damping. There is a Doppler broadening around the cyclotron resonance and this overlaps with the ion–ion hybrid layer. Low toroidal mode numbers and ion temperature in the range of 5–20 keV are favorable for enhancing the main ion damping relative to electron damping. In contrast to the neutral beam injection, which penetration strongly depends on machine size and plasma density, the proposed ICRF-based direct ion heating scenario is shown to be scalable and applicable to both larger and smaller tokamak devices within practical constraints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Discrete Hankel Transform Approach to Nuclear Data Processing for Fusion Applications

This study introduces advancements to the numerical solutions employed in the processing of nuclear data for fusion applications. It leverages the convolution theorem and Fourier transform techniques to enhance computational efficiency and broaden applicability. Building upon a previously reported discrete Hankel transform approach for Doppler broadening, this work refines the solution of convolution integrals central to these applications. The methodology provides a general and unified framework for evaluating any convolution operation, regardless of whether the underlying problem involves temperature effects in nuclear reactions. The applicability to the nuclear data processing for fusion is demonstrated by deriving the convolution integrals for some of the fusion-related quantities. As before, the convolution operation utilizes a Gaussian-based kernel; however, the discrete Hankel transform of order $𝛼$ = $\frac{1}{2}$ is now applied to the forward Fourier transform of the nonkernel argument, rather than the inverse Fourier transform. This modification eliminates the need for the integration of the nonkernel, cross section–based function, which is a step that posed challenges for certain pointwise cross-section representations. It also removes the requirement for cross-section linearization. Optimized for graphics processing unit architectures, the approach significantly improves computational performance. These advancements are currently under evaluation as the foundation for the next-generation thermonuclear data file processing codes being developed at Lawrence Livermore National Laboratory.

Nuclear science and engineering↗

Effects of Nonzero-frequency Fluctuations on Turbulence Spectral Observations

In situ observations of turbulence spectra in space plasmas are usually interpreted as wavenumber spectra, assuming that the fluctuation frequency is negligible in the plasma flow frame. We explore the effects of nonzero frequency in the plasma flow frame on turbulence spectral observations. The finite frequency can be caused by either propagating waves or nonlinear broadening of nonpropagating structures. We show that the observed frequency spectrum can be modified by the nonzero frequency of turbulent fluctuations in several ways. Specifically, (i) frequency broadening results in a minor modification to the observed spectrum, primarily acting as a smoothing kernel of the spectrum near the spectral break, while the asymptotic spectral index remains unchanged; (ii) wave propagation can affect the observed spectral index for anisotropic turbulence. The effect is significant at low frequencies and weaker at high frequencies, leading to a "concave" shape of the observed perpendicular spectrum; (iii) the Doppler shift for forward- and backward-propagating Elsasser modes can result in a nonzero cross helicity for critical-balanced turbulence since the effect of the Doppler shift favors outward-propagating waves systematically, resulting in an observed imbalance. These results may have important implications for the interpretation of solar wind flows observed by Parker Solar Probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Stark-split beam and carbon charge exchange emissions for simultaneous B-field and temperature/rotation analysis at DIII-D

A set of two newly designed, single-channel Czerny–Turner spectrometers has been deployed at the DIII-D tokamak for measurements of the motional Stark effect (MSE) split beam emission and the C6+ (CVI) carbon charge exchange recombination (CER) emission at high spectral (δλ = 0.13 nm) and temporal (1–5 kHz) resolution. High throughput optics (f/# = 2.8) allow for good signal-to-noise at high time resolution using fast EMCCD detectors. The MSE emission allows for spectral fitting of the magnitude and direction of the local B-field, while the carbon emission yields local ion temperature and toroidal rotation information. To reduce so-called Doppler broadening of the MSE emission, a new channel-specific variable lens-masking approach has been developed. Experimental data collected from the 2023 DIII-D experimental campaign demonstrate the signal quality and instrument fidelity for both diagnostic measurements. Moreover, initial CER data analysis shows a clear evolution of the toroidal rotation during edge localized modes. Initial progress on the advanced MSE model, including a new validated ray-trace model of the DIII-D collection optics, is shown via sensitivity analysis.

Instruments & Instrumentation↗

How Bright in Gravitational Waves are Millisecond Pulsars for the Galactic Center GeV Gamma-Ray Excess? A Systematic Study

The existence of dark matter (DM) is supported by various macroscopic observations, but its microscopic nature remains elusive. The Galactic Center GeV gamma-ray excess (GCE) has been a leading candidate signal for particle dark matter annihilation. However, an unresolved population of millisecond pulsars (MSPs) in the bulge provides the alternative explanation for the excess. Identifying these MSPs in electromagnetic bands is difficult due to source confusion, pulse broadening, and extinction. Gravitational waves (GWs) provide a complementary probe: a steadily rotating, non-axisymmetric MSP emits a nearly monochromatic GW signal in the sensitive band of ground-based detectors, with amplitude set by its ellipticity. In this work, we systematically investigate the GW emission from the MSP population proposed to explain the GCE and its detectability with current and future detectors. We consider three major scenarios for the origin of ellipticity and model the population properties of these MSPs. We also consider both isolated MSPs and MSPs in binary systems, as well as Doppler effects in the detection. We find that while the signal is below the reach of current interferometers, next-generation detectors such as the Einstein Telescope (ET) and Cosmic Explorer (CE) can detect a fraction of those MSPs, offering a novel test of the MSP interpretation of the GCE. Future directed searches toward the Galactic Center with continued improvements in sensitivities will either uncover this long-sought MSP population or place stringent limits on their ellipticities and abundance, with important implications for both the astrophysical and dark-matter interpretations of the GCE.

Lei, Ming-Yu [Purple Mountain Observ.; USTC, Hefei↗

The influence of laser energy on deuterium emission characteristics from a Zircaloy-4 plasma

Laser-produced plasma coupled with optical emission spectroscopy (OES) is a promising technique for detecting certain isotopes, with unique capabilities such as standoff and rapid detection and minimal to no sample preparation requirements. The key figure-of-merit for isotopic analysis using optical spectroscopy tools is the linewidth relative to the isotope shift. Although the isotopes of hydrogen (1H, 2H, and 3H) possess large isotopic shifts (1H–2H ≈ 180 pm, 1H–3H ≈ 240 pm), being a light element, the H transitions are susceptible to various broadening mechanisms in the plasma environment. One of the critical parameters that influence the linewidth of a transition in an LPP is the incident laser energy. In the present study, we evaluated the role of laser energy on plume expansion dynamics, deuterium emission intensity, and linewidth in a nanosecond laser-produced Zircaloy-4 plasma. The changes in 2Hα emission intensity and linewidth were investigated for varying laser fluence and time after plasma onset. Spatially resolved and spatially integrated OES were performed and compared to investigate the emission spectral features and linewidth of 2Hα. Monochromatic two-dimensional time-resolved imaging was also performed to understand the morphology of the deuterium and protium emission relative to all species in the plume. Our results showed that 1Hα and 2Hα emissions predominantly occur closer to the target. Measurements of 2Hα linewidth approached similar values at later times of plasma evolution regardless of the laser energy. The linewidths of the 2Hα transition showed insignificant differences between spatially resolved and spatially integrated measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗