Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler shift spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

The influence of laser energy on deuterium emission characteristics from a Zircaloy-4 plasma

Laser-produced plasma coupled with optical emission spectroscopy (OES) is a promising technique for detecting certain isotopes, with unique capabilities such as standoff and rapid detection and minimal to no sample preparation requirements. The key figure-of-merit for isotopic analysis using optical spectroscopy tools is the linewidth relative to the isotope shift. Although the isotopes of hydrogen (1H, 2H, and 3H) possess large isotopic shifts (1H–2H ≈ 180 pm, 1H–3H ≈ 240 pm), being a light element, the H transitions are susceptible to various broadening mechanisms in the plasma environment. One of the critical parameters that influence the linewidth of a transition in an LPP is the incident laser energy. In the present study, we evaluated the role of laser energy on plume expansion dynamics, deuterium emission intensity, and linewidth in a nanosecond laser-produced Zircaloy-4 plasma. The changes in 2Hα emission intensity and linewidth were investigated for varying laser fluence and time after plasma onset. Spatially resolved and spatially integrated OES were performed and compared to investigate the emission spectral features and linewidth of 2Hα. Monochromatic two-dimensional time-resolved imaging was also performed to understand the morphology of the deuterium and protium emission relative to all species in the plume. Our results showed that 1Hα and 2Hα emissions predominantly occur closer to the target. Measurements of 2Hα linewidth approached similar values at later times of plasma evolution regardless of the laser energy. The linewidths of the 2Hα transition showed insignificant differences between spatially resolved and spatially integrated measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Precision Spectroscopy of 20 O Benchmarking Ab Initio Calculations in Light Nuclei

The excited states of unstable 20 O were investigated via γ-ray spectroscopy following the 19 O(d, p) ⁢20 O reaction at 8 A⁢ MeV. By exploiting the Doppler shift attenuation method, the lifetimes of the $2^+_2$ and $3^+_1$ states were firmly established. From the γ-ray branching and E⁢2/M⁢1 mixing ratios for transitions deexciting the $2^+_2$ and $3^+_1$ states, the B⁡(E⁢2) and B⁡(M⁢1) were determined. Various chiral effective field theory Hamiltonians, describing the nuclear properties beyond ground states, along with a standard USDB interaction, were compared with the experimentally obtained data. Such a comparison for a large set of γ-ray transition probabilities with the valence space in medium similarity renormalization group ab initio calculations was performed for the first time in a nucleus far from stability. It was shown that the ab initio approaches using chiral effective field theory forces are challenged by detailed high-precision spectroscopic properties of nuclei. Finally, the reduced transition probabilities were found to be a very constraining test of the performance of the ab initio models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D

A 16 channel spectroscopy system has been installed on DIII-D to provide information about the energy distribution of the atomic neutrals using the Doppler shift and broadening of passive Balmer-α emission. Here, the lines of sight are dominantly in the toroidal direction, with tangencies near the lowest point on closed magnetic flux surfaces moving from the lower divertor upward into the confined plasma. This allows the system to provide details of the neutrals as they undergo various atomic physics processes while traveling upward from the lower divertor. The spectrally resolved measurements provide several advantages that complement typical optical filter based measurements of hydrogenic spectral lines. These include more direct measurements of the neutrals that fuel deeper in the plasma and capturing neutral velocity distribution information via the Doppler broadened and shifted line. In addition, the spectral separation of higher energy “thermal” neutrals and bright cold emission from the scrape-off layer allows for a more straightforward calculation of the underlying neutral densities based on the emission because of the dependence of the thermal emission on confined plasma properties that are approximately flux functions and well measured.

Atomic and molecular physics↗

Measurement and analysis of the Doppler broadened energy spectra of gamma radiation originating from the annihilation of positrons incident on clean and adsorbate-covered surfaces

We present measurements and theoretical modeling demonstrating the capability of coincidence Doppler broadened (CDB) annihilation gamma spectroscopy to provide element-specific information from the topmost atomic layer of surfaces. Our measurements show that the energy spectra of Doppler-shifted annihilation gamma photons emitted following the annihilation of positrons from the topmost atomic layers of clean and adsorbate covered surfaces of gold (Au), silver (Ag) and copper (Cu) differ significantly. The shape of the Doppler-broadened gamma spectrum, as analyzed using ratio curves, indicates that the elemental composition of the surface can still be identified despite contributions from positronium annihilation and a significant reduction in core electron annihilation. We estimate the chemical composition of the various probed surfaces by modeling the ratios of the measured Doppler spectra with respect to the Doppler spectra from a clean Cu surface using a linear combination of calculated ratio curves. The fitting of the experimental ratio curves was used to obtain an estimate of the elemental composition of Cu surfaces with sulfur segregation, oxygen adsorption, a thin film of Selenium (Se), and a single layer of graphene (SLG). A similar analysis was performed on the Ag surface with environmental adsorbates, the same surface after argon ion sputtering, as well as a sputter cleaned Au surface. The surface compositions obtained from the analysis of the CDB data were compared to the compositions obtained using positron annihilation induced Auger electron spectroscopy (PAES). Our results show that CDB can detect, identify, and quantify, sub-monolayer adsorbates and a single atomic layer deposited on metal substrates.

Lotfimarangloo, Sima [Univ. of Texas, Arlington, T↗

Utilizing Quantum Cascade Lasers for Ultranarrow Velocity Resolution and Quantum-State Selectivity in Molecular Beam Scattering and Spectroscopy

Here, we demonstrate the capability of a narrow linewidth quantum cascade laser (QCL) to selectively excite a very narrow velocity range of nitric oxide (σ ≤ 7(3) m/s) with a pure ro-vibrational quantum state. By implementing a counter-propagating geometry, the molecules are selectively excited according to the Doppler shift of the ro-vibrational transition frequency such that the velocity width associated with the excited molecules depends only on the QCL linewidth. We demonstrate a velocity distribution limited by the effective linewidth of our free-running QCL (Γ = 3.2 MHz). Our development provides a cost-effective, flexible approach to resolve quantum-state selective chemical dynamics with excellent velocity resolution in a wide variety of molecules with infrared-active transitions. This technique has been formulated to provide ultrahigh collisional energy resolution in molecular beams to delineate final quantum-state product pairs in studies of molecular collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ORNL Portable Diagnostic Package for Evaluating Mirror Performance

Oak Ridge National Laboratory (ORNL) and Realta Fusion successfully executed a one-year collaborative effort to deploy the Portable Diagnostic Package (PDP) on the Wisconsin HTS Axisymmetric Mirror (WHAM) and to assess future diagnostic needs. The PDP consists of an optical emission spectroscopy (OES) subsystem and a Thomson scattering (TS) subsystem. Within the first two months, the PDP OES subsystem was installed, integrated with WHAM timing, and handed over to trained Realta personnel. It immediately delivered multi-channel impurity surveys and the first spatially resolved plasma-rotation profiles inferred from C III Doppler shifts. The TS subsystem was commissioned within the first six months; transportation of the class IV laser system, approval of the safety plan, and the integration with WHAM timing with 100 ns resolution. The TS subsystem provided the first localized electron temperature measurements in WHAM commissioning shots. Leveraging these results, the team has discussed a diagnostic concept map for Realta’s next-step facility, Anvil, identifying line-of-sight constraints, required temporal resolution, and hardware upgrades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗

Measurement of small island characteristics using high resolution ECE and CER at DIII-D

Abstract The measurements using the high resolution electron cyclotron emission radiometry and the charge exchange and recombination spectroscopy are processed using analytic formulas to allow for the detection of islands as small as 1.9 cm. In contrast to large, saturated magnetic islands which are relatively well understood to be governed by the loss of bootstrap current inside the island, small islands are less well understood due to the difficulty of their accurate measurement in tokamaks. Here, ‘small’ islands are islands comparable in size to the ion banana width, which can be as small as 0.8 cm at DIII-D. The new measurement methods allow for the detection of small island widths when the predicted increase of mode frequency to match the Doppler shifted ion diamagnetic frequency is observed. Therefore, for the first time, the mode frequency increase can be unambiguously associated to the acceleration of the magnetic island propagation. Such association allows for a further development and validation of the much-debated theory of ion polarization currents, which is thought to govern the small island growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗