Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 538: International Dosimetry Intercomparison Exercise with Godiva-IV [Slides]

Presentation on International Dosimetry Intercomparison Exercise with Godiva-IV. This presentation details Department of Energy (DOE) requirements and irradiation. Graphs show Neutron dose conversion factors, Neutron dose characterization, and Photon dose characterization. Results of 2m, 3m, and 4m tests are then compared to DOE standards. Findings show photon dose measurements were limited by instrumentation not available. Additionally, there has been a turnover of staff in dosimetry. However, funding is being provided for Universal Nuclear Accident Dosimeter (U-NAD).

61 RADIATION PROTECTION AND DOSIMETRY↗

Saturn Radiation Dose Environment Characterization

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

IER 484: AFRRI Field Characterization Measurements [Slides]

This lecture includes discussion on the future work of finalizing the data analysis with dose as a function of radial distance and ion chamber integral. Further on agenda is to write manuscript of AFRRI dose characterization and write manuscripts of all NCSP-funded NAD work. Finally, it talks on the goal to publish in Radiation Measurements special issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atom Probe Tomography Characterization of High-Dose Ion Irradiated MA957

This paper presents a comprehensive characterization study of the microstructural responses to ion irradiation of the oxide dispersion strengthened (ODS) ferritic alloy MA957 using atom probe tomography (APT). The MA957 specimens were irradiated by 1.8 MeV Cr3+ ions to doses and temperatures relevant to advanced fast reactors (100 and 500 dpa at 400-500 °C). The average sizes of the YTiO particles decreased slightly after irradiation at all temperatures, with the most pronounced change at 400 °C. The particle number densities for 400 and 500 °C were slightly below number densities for the unirradiated condition, while the values were slightly higher at 420 and 450 °C. This behavior is consistent with the Nelson-Hudson-Mazey rate theory model that considers the competing effects between recombination and dissolution. An increase in the Y/Ti ratio of the YTiO particles was observed at the two lower temperatures. The formation of Cr-rich precipitates (a') was observed in specimens irradiated at temperatures up to 450 °C. Irradiation-induced segregation on grain boundaries was also investigated. Grain boundary element concentration profiles and ion maps demonstrate differences among the irradiation temperatures, with most datasets differing from the unirradiated condition. A key focus of this ion irradiation study is the high-dose response, and this quantitative assessment revealed relatively small but distinct effects of irradiation on microstructure evolution. Overall, these results showing minor second phase evolution suggest that MA957 should retain mechanical performance generally well up to 500 dpa for the irradiation temperatures studied.

Wang, Jing↗

A Comparison of Cs-137 γ Rays and 320-kV X-Rays in a Mouse Bone Marrow Transplantation Model

US homeland security concerns regarding the potential misuse of some radiation sources used in radiobiological research, for example, cesium-137 ( 137 Cs), have resulted in recommendations by the National Research Council to conduct studies into replacing these sources with suitable X-ray instruments. The objective of this research is to compare the effectiveness of an X-RAD 320 irradiator (PXINC 2010) with a 137 Cs irradiator (Gammacell-1000 Unit) using an established bone marrow chimeric model. Using measured radiation doses for each instrument, we characterized the dose–response relationships for bone marrow and splenocyte ablation, using a cytotoxicity-hazard model. Our results show that the X-RAD 320 photon energy spectrum was suitable for ablating bone marrow at the 3 exposure levels used, similar to that of 137 Cs photons. However, the 320-kV X-rays were not as effective as the much higher energy γ rays at depleting mouse splenocytes. Furthermore, the 3 X-ray levels used were less effective than the higher energy γ rays in allowing the successful engraftment of donor bone marrow, potentially as a result of the incomplete depletion of the spleen cells. More defined studies are warranted for determining whether bone marrow transplantation in mice can be successfully achieved using 320-kV X-rays. A higher X-ray dose then used is likely needed for transplantation success.

320-kV X-rays↗

Congenital Malformations and Perinatal Deaths Among the Children of Atomic Bomb Survivors: A Reappraisal

From 1948 to 1954, the Atomic Bomb Casualty Commission conducted a study of pregnancy outcomes among births to atomic bomb survivors (Hiroshima and Nagasaki, Japan) who had received radiation doses ranging from 0 Gy to near-lethal levels. Past reports (1956, 1981, and 1990) on the cohort did not identify significant associations of radiation exposure with untoward pregnancy outcomes, such as major congenital malformations, stillbirths, or neonatal deaths, individually or in aggregate. We reexamined the risk of major congenital malformations and perinatal deaths in the children of atomic bomb survivors (n = 71,603) using fully reconstructed data to minimize the potential for bias, using refined estimates of the gonadal dose from Dosimetry System 2002 and refined analytical methods for characterizing dose-response relationships. The analyses showed that parental exposure to radiation was associated with increased risk of major congenital malformations and perinatal death, but the estimates were imprecise for direct radiation effects, and most were not statistically significant. Nonetheless, the uniformly positive estimates for untoward pregnancy outcomes among children of both maternal and paternal survivors are useful for risk assessment purposes, although extending them to populations other than the atomic bomb survivors comes with uncertainty as to generalizability.

60 APPLIED LIFE SCIENCES↗

Improving Dose-Optimization Processes Used in Oncology Drug Development to Minimize Toxicity and Maximize Benefit to Patients

This review highlights strategies to integrate dose optimization into premarketing drug development and discusses the underlying statistical principles. Poor dose optimization can have negative consequences for patients, most commonly because of toxicity, including poor quality of life, reduced effectiveness because of inability of patients to stay on current therapy or receive subsequent therapy because of toxicities, and difficulty in developing combination regimens. We reviewed US Food and Drug Administration initial approvals (2019-2021) of small molecules and antibody-drug conjugates for oncologic indications to determine the proportion with a recommended dosage at the maximum tolerated dose or the maximal administered dose, to characterize the use of randomized evaluations of multiple dosages in dose selection, to describe the frequency of dose modifications at the recommended dosage, and to identify case examples that highlight key principles for premarket dose optimization during drug development. Herein, we highlight major principles for dose optimization and review examples of recent US Food and Drug Administration approvals that illustrate how investigation of dose- and exposure-response relationships and use of randomized dose trials can support dose optimization. Although there has been some progress, dose optimization through randomized dose evaluation in oncology trials is not routinely conducted. Dose optimization is essential to ensure that patients receive therapies which maximize efficacy while minimizing toxicity.

Oncology↗

Modeling Cell Survival Fraction and Other Dose-Response Relationships for Immunodeficient C.B-17 SCID Mice Exposed to 320-kV X Rays

US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.

Scott, Bobby R.↗

Shielding Thickness Recommendations for an Activated Target Segment Vertical Stave

This analysis examines the shielding requirements needed to plan maintenance and handling operations of the target segment assembly vertical stave. It provides the analyses and results that fulfill the requirements of Task Order TO-150. The vertical stave is a stainless-steel welded assembly that carries cooling water to and from the target block. In this report, we characterize the dose rates and shielding requirements for the vertical stave only, i.e., separated from the target block. Shielding and dose rates for the target block only have been calculated in response to TO-008.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of chronic low-dose radiation on cataract prevalence and characterization in wild boar (Sus scrofa) from Fukushima, Japan

This study evaluated cataracts in wild boar exposed to chronic low-dose radiation. We examined wild boar from within and outside the Fukushima Exclusion Zone for nuclear, cortical, and posterior subcapsular (PSC) cataracts in vivo and photographically. Plausible upper-bound, lifetime radiation dose for each boar was estimated from radioactivity levels in each animal’s home range combined with tissue concentrations of 134+137Cesium. Fifteen exposed and twenty control boar were evaluated. There were no significant differences in overall prevalence or score for cortical or PSC cataracts between exposed and control animals. Nuclear (centrally located) cataracts were significantly more prevalent in exposed boar (p<0.05) and had statistically higher median scores. Plausible upper-bound, lifetime radiation dose ranged from 1 to 1,600 mGy in exposed animals, with no correlation between dose and cortical or PSC score. While radiation dose and nuclear score were positively associated, the impact of age could not be completely separated from the relationship. Additionally, the clinical significance of even the highest scoring nuclear cataract was negligible. Based on the population sampled, wild boar in the Fukushima Exclusion Zone do not have a significantly higher prevalence or risk of cortical or PSC cataracts compared to control animals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferring relative dose-dependent color center populations in proton irradiated thoria single crystals using optical spectroscopy

In this work, we have utilized photoluminescence spectroscopy and optical ellipsometry to characterize the dose-dependence of the photoluminescence emission intensity and changes in optical absorption of thoria single crystals subject to irradiation with energetic protons at room- and elevated-temperatures. The photoluminescence peaks and the optical absorption bands are attributed to creation of new electronic states emerging from defects resulting from displacement damage. These bands are most likely associated with electrons trapped at the oxygen vacancy sites similar to color centers formed in other irradiated oxides and halides. Our experimental observations are supported by a standard density functional theory calculation of the electronic structure in pristine and oxygen vacancy-bearing thoria crystals. The dose-dependence of the intensity of the photoluminescence peaks is used to parameterize a rate theory model that estimates the concentration of color centers in the irradiated crystals. This parameterization provides optimized migration barrier parameters for oxygen interstitials and vacancies that simultaneously capture the optical response of the crystals irradiated at room- and elevated-temperature. These optical spectroscopy techniques offer a promising pathway to characterize the population of color centers formed at the sites of oxygen anion vacancies, particularly in irradiated nuclear fuels, where atomic-level defects cannot be readily imaged using electron microscopy. When combined with other direct and indirect characterization tools, our approach can provide new insight into defect formation and accumulation in energy materials over single atomic to extended length scales.

36 MATERIALS SCIENCE↗

Plasmonic Ag nanocomposite phosphate glasses produced via γ-ray irradiation as reduction route

This paper reports on the impact of γ-ray irradiation (10, 100 kGy) on melt-quenched Ag + -doped phosphate glass and the effects of subsequent thermal processing leading to the production of plasmonic Ag nanocomposites. The γ-irradiated glasses were characterized alongside the pristine by differential scanning calorimetry (DSC), Raman spectroscopy, electron paramagnetic resonance (EPR) spectroscopy, optical absorption, and photoluminescence (PL) spectroscopy. DSC characterization showed consistent glass transition temperatures (T g ) before and after γ-irradiation whereas the crystallization temperatures tended to decrease with increasing γ-ray dose. However, a lack of alteration of the glass network structure was supported by Raman spectroscopy. Room temperature EPR spectra clearly showed the formation of phosphorus oxygen hole center (POHC) defects in the undoped host, in addition to another doublet likely associated with a P 3 defect. The presence of paramagnetic silver species encompassing Ag 2+ and 107/109 Ag 0 atoms was also indicated in the silver-activated glass together with POHC defects. Optical absorption spectra were also consistent with the presence of various radiation-induced centers. Further analyzing the glass absorption edge via Tauc plots suggested the formation of electron center (EC) defects in γ-irradiated samples wherein the silver-doped glass exhibited decreasing band gap energies with increasing γ-ray dose. The PL characterization showed the silver-related radio-PL effect was induced exhibiting broad band emission with two maxima around 500 and 625 nm stemming from various molecular Ag$^{x+}_{n}$ clusters. Emission decay analyses revealed that the longer wavelength emission exhibited slower decay. The highest radiation dose of 100 kGy however resulted in weaker emission and faster decay kinetics attributed to energy transfer between the luminescent silver species and POHC defects. Finally subjecting the γ-irradiated Ag-doped glasses to heat treatment near the T g at 490 °C led to the development of the surface plasmon resonance of Ag nanoparticles (NPs) and the vanishing of the Ag$^{x+}_{n}$ clusters luminescence. In conclusion, the presence of the matrix-related EC defects was deemed accountable for the thermally induced reduction and consequent precipitation of Ag NPs making the plasmonic glasses attractive for photonic applications such as nonlinear optics.

36 MATERIALS SCIENCE↗