General Area Dose Rate Maps to Support Advanced Reactor Experiments
Co-op poster project on advanced reactor technology. Results from advanced reactor projects where dose maps were calculated, and dosage fields are displayed.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Co-op poster project on advanced reactor technology. Results from advanced reactor projects where dose maps were calculated, and dosage fields are displayed.
A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.
A microprocessor-controlled on-board TLD system, 'Pille'96', was used during the NASA4 (1997) mission to monitor the cosmic radiation dose inside the Mir Space Station and to measure the extra dose to two astronauts in the course of their extravehicular activity (EVA). For the EVA dose measurements, CaSO4:Dy bulb dosemeters were located in specially designed pockets of the ORLAN spacesuits. During an EVA lasting 6 h, the dose ratio inside and outside Mir was measured. During the EVA, Mir crossed the South Atlantic Anomaly (SAA) three times. Taking into account the influence of these three crossings the mean EVA/internal dose rate ratio was 3.2. Internal dose mapping using CaSO4:Dy dosemeters gave mean dose rates ranging from 9.3 to 18.3 microGy h-1 at locations where the shielding effect was not the same. Evaluation results of the high temperature region of LiF dosemeters are given to estimate the mean LET.
Electron beam (e-beam) irradiation is an advanced method for removing the emerging organic contaminants in wastewater, such as 1,4-dioxane, and per- and polyfluoroalkyl sub?stances (PFAS), which have the potential to be regulated in the near future but are difficult to degrade by conventional treatment methods. This dissertation was based on a collabo?rating study between Jefferson Lab (Jlab) and Hampton Roads Sanitation District (HRSD) to evaluate the impacts of e-beam irradiation on the degradation of 1,4-dioxane and PFAS. It presents the detailed design of an e-beam irradiation beamline, the beamline simulation using general particle tracer (GPT), the installation, and the successful commissioning. The beamline is an extended section to the Upgraded Injector Test Facility (UITF) at Jlab, which is a continuous wave (CW), superconducting radio frequency (SRF) linear accelerator with an energy up to 10 MeV. To let the sample volume receive a significant and uniform dose distribution, the sample target was designed by investigating the dose distribution simulated with a Monte-Carlo code, FLUKA. The optimized beam energy was 8 MeV and the beam current for irradiation was ? 100 nA. With the use of a solenoid and a raster, the electron beam was expanded to the optimized size, 1? ? 15 mm, at the sample target. This dis?sertation also presents the irradiation experiments for 64 1,4-dioxane samples and 48 PFAS samples in different water matrices, including real wastewater, which were prepared and an?alyzed by HRSD. The absorbed doses of samples were obtained by designing a new method that combines the FLUKA simulation and dose mapping experiments. The irradiation re?sults showed that around 95% of 1,4-dioxane was removed at a low dose of ? 2 kGy, and PFAS was possibly removed at a lower dose compared to similar research. This work is a first implementation of SRF technology for wastewater irradiation. It pro?vides a valuable new research platform for wastewater remediation. This will be in support of future industrial applications of advanced SRF technologies and better understanding of the effect of e-beam irradiation on wastewater or water treatment.
This report documents the progress made in simulating the HERMES-III Magnetically Insulated Transmission Line (MITL) and courtyard with EMPIRE and ITS. This study focuses on the shots that were taken during the months of June and July of 2019 performed with the new MITL extension. There were a few shots where there was dose mapping of the courtyard, 11132, 11133, 11134, 11135, 11136, and 11146. This report focuses on these shots because there was full data return from the MITL electrical diagnostics and the radiation dose sensors in the courtyard. The comparison starts with improving the processing of the incoming voltage into the EMPIRE simulation from the experiment. The currents are then compared at several location along the MITL. The simulation results of the electrons impacting the anode are shown. The electron impact energy and angle is then handed off to ITS which calculates the dose on the faceplate and locations in the courtyard and they are compared to experimental measurements. ITS also calculates the photons and electrons that are injected into the courtyard, these quantities are then used by EMPIRE to calculated the photon and electron transport in the courtyard. The details for the algorithms used to perform the courtyard simulations are presented as well as qualitative comparisons of the electric field, magnetic field, and the conductivity in the courtyard. Because of the computational burden of these calculations the pressure was reduce in the courtyard to reduce the computational load. The computation performance is presented along with suggestion on how to improve both the computational performance as well as the algorithmic performance. Some of the algorithmic changed would reduce the accuracy of the models and detail comparison of these changes are left for a future study. As well as, list of code improvements there is also a list of suggested experimental improvements to improve the quality of the data return.
Commercial-scale production of Mo-99 demands a facility-wide assessment of radiation-induced degradation across process equipment, instrumentation, and purification media. Key factors— total ionizing dose, dose rate, radiolysis-driven chemistry, thermal loads, activation, and any neutron-related effects—should inform material selection, shielding, and component layout. Purification materials (sorbents, resins, filters, seals, housing) require particular attention to ensure that irradiation does not alter selectivity or capacity, generate fines, or introduce leachables that could compromise Mo-99 purity or downstream Tc-99m generator performance. Dose mapping, accelerated irradiation testing, and studies of extractables/leachables together provide the basis for setting maintenance, calibration, and replacement intervals and for qualifying materials that retain mechanical integrity, chemical compatibility, and radiopurity over their service life.
The data obtained in earth orbit by the Radiation and Meteoroid Satellite (RMS) were interpreted and reduced to a form which will be usable by future space experimenters. The required tasks are detailed. Computer programs were written which lifted the raw data and associated emphemeris data from the GFE magnetic tapes. The engineering data was then used to evaluate the performance of the spacecraft and the experiments. The radiation data was used to prepare flux, spectral, and dose maps of the South Atlantic magnetic anomaly where possible. The meteoroid data was used to determine a rough estimate of the meteoroid flux and in general evaluate the performance of the thin-film meteoroid sensors. The degree of success of the RMS mission was evaluated in light of the separation anomaly which occurred between RMS and OFO during launch.
Objective: To develop an easy-to-use software application to predict and mitigate radiation effects in research environment, space instruments, nuclear plants and medical facilities and help nonproliferation and national security efforts. Tech-X will develop standalone software libraries and command-line tools for ( 1) translating CAD into tessellated surfaces and tetrahedral meshes in GDML (for Geant4 and MARS 15), ROOT (for MARS 15) and HDF5 (for compact representation and for the visualization) formats, (2) healing CAD geometries to make them suitable for Monte Carlo simulations; (3) creating uniform and variable Cartesian and cylindrical meshes for detailed scoring; and ( 4) efficient Monte Carlo navigation in CAD geometries. JLAB will finish automation of simulations of residual dose in CAD geometries and integrate Tech-X software into Geant4 and MARS15. Finally, Tech-X will develop a Graphical User Interface to set up and heal CAD geometries, create input files, run and visualize simulations for residual dose. This application will run on local desktops, local and remote clusters and supercomputers and will be made available through public clouds, such as Amazon Web Services.
In this paper, we have developed a methodology to estimate the spatiotemporal distribution of radiation air dose rates around the Fukushima Daiichi Nuclear Power Plant (FDNPP). In our exploratory data analysis, we found that (1) the temporal evolution of dose rates is composed of a log-linear decay trend and fluctuations of air dose rates that are spatially correlated among adjacent monitoring posts; and (2) the slope of the log-linear environmental decay trend can be represented as a function of the apparent initial dose rates, coordinate position, land-use type, and soil type. From these observations, we first estimated the log-linear decay trend at each location based on these predictors, using the random forest method. We then developed a modified Kalman filter coupled with a Gaussian process model to estimate the dose-rate time series at a given location and time. We applied this method to the Fukushima evacuation zone (as of March 2017), which included 17 monitoring post locations (with monitoring datasets collected between 2014 and 2018) and generated a time series of dose-rate maps. Our results show that this approach allows us to produce accurate spatial and temporal predictions of radiation dose-rate maps using limited spatiotemporal measurements.
The Moon has a harsh radiation environment that poses significant challenges to future science and exploration activities. Exposure hazards from space radiation are primarily due to galactic cosmic rays (GCRs) and solar energetic particles (SEPs) that are incident at the lunar surface from all directions. The Lunar Reconnaissance Orbiter’s (LRO) Cosmic Ray Telescope for Effects of Radiation (CRaTER) instrument has been observing space radiation around the Moon since 2009. The CRaTER observations show a steady GCR flux with intermittent SEP events that have much higher fluxes. During solar minimum, the GCR flux is higher, while the SEP events are less common. On the other hand, during solar maximum, the SEP events have are more frequent and the GCR flux is lower. This is due to variations in solar activity. GCRs have characteristic energies spanning from 1 MeV to 10s of GeV. SEPs, however, have much lower energy ranges of 50 keV to 100s of MeV.
The NASA Space Radiation Laboratory (NSRL) facility has been used successfully for many years to generate ion beams for radiation research experiments by NASA investigators. Recently, modifications were made to the beam lines to allow rapid switching between different types of ions and energies, with the aim to simulate the Galactic Cosmic Rays (GCR) environment. As this will be a focus of space radiation research for upcoming years, the stochastic radiation track structure code RITRACKS (Relativistic Ion Tracks) was modified to simulate beams of various ion types and energies during time intervals specified by the user at the microscopic and nanoscopic scales. For example, particle distributions of a mixed 344.1-MeV protons (18.04 cGy) and 950-MeV/n iron (5.64 cGy) beam behind a 20 g/cm(exp 2) aluminum followed by a 10 g/cm(exp 2) polyethylene shield as calculated by the code GEANT4 were used as an input field in RITRACKS. Similarly, modifications were also made to simulate a realistic radiation environment in a spacecraft exposed to GCR by sampling the ion types and energies from particle spectra pre-calculated by the code HZETRN. The newly implemented features allows RITRACKS to generate time-dependent differential and cumulative 3D dose voxel maps. These new capabilities of RITRACKS will be used to investigate dose-rate effects and synergistic interactions of various types of radiations for many end points at the microscopic and nanoscopic scales such as DNA damage and chromosome aberrations.
The estimate of absorbed dose to individual organs of a space crewmember is affected by the geometry of the anatomical model of the astronaut used in the radiation transport calculation. For astronaut dosimetry, NASA currently uses the computerized anatomical male (CAM) and computerized anatomical female (CAF) stylized phantoms to represent astronauts in its operational radiation dose analyses. These phantoms are available in one size and in two body positions. In contrast, the UF Hybrid Adult Male and Female (UFHADM and UFHADF) phantoms have organ shapes based on actual CT data. The surfaces of these phantoms are defined by non-uniform rational B-spline surfaces, and are thus flexible in terms of body morphometry and extremity positioning. In this study, UFHADM and UFHADF are scaled to dimensions corresponding to 5th, 50th, and 95th percentile (PCTL) male and female astronauts. A ray-tracing program is written in Visual Basic 2008, which is then used to create areal density maps for dose points corresponding to various organs within the phantoms. The areal density maps, along with appropriate space radiation spectra, are input into the NASA program couplet HZETRN/BRYNTRN, and organ doses are calculated. The areal density maps selected tissues and organs of the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared. In addition, the organ doses for the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared to organ doses for CAM and CAF.
The flight of a human phantom torso with head that containing active dosimeters at 5 organ sites and 1400 TLDs distributed in 34 1" thick sections is described. Experimental dose rates and quality factors are compared with calculations for shielding distributions at the sites using the Computerized Anatomical Male (CAM) model. The measurements were complemented with those obtained from other instruments. These results have provided the most comprehensive data set to map the dose distribution inside a human and to assess the accuracy of radiation transport models and astronaut radiation risk.
The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.
The REID quantifies the lifetime risk of death from radiation-induced cancer in an exposed astronaut. The NASA Space Cancer Risk (NSCR) 2012 mode incorporates elements from physics, biology, epidemiology, and statistics to generate the REID distribution. The current model quantifies the space radiation environment, radiation quality, and dose-rate effects to estimate a NASA-weighted dose. This weighted dose is mapped to the excess risk of radiation-induced cancer mortality from acute exposures to gamma rays and then transferred to an astronaut population. Finally, the REID is determined by integrating this risk over the individual's lifetime. The calculated upper 95% confidence limit of the REID is used to restrict an astronaut's permissible mission duration (PMD) for a proposed mission. As a statistical quantity characterized by broad, subjective uncertainties, REID estimates for space missions result in wide distributions. Currently, the upper 95% confidence level is over 350% larger than the mean REID value, which can severely limit an astronaut's PMD. The model incorporates inputs from multiple scientific disciplines in the risk estimation process. Physics and particle transport models calculate how radiation moves through space, penetrates spacecraft, and makes its way to the human beings onboard. Epidemiological studies of exposures from atomic bombings, medical treatments, and power plants are used to quantify health risks from acute and chronic low linear energy transfer (LET) ionizing radiation. Biological studies in cellular and animal models using radiation at various LETs and energies inform quality metrics for ions present in space radiation. Statistical methodologies unite these elements, controlling for mathematical and scientific uncertainty and variability. Despite current progress, these research platforms contain knowledge gaps contributing to the large uncertainties still present in the model. The NASA Space Radiation Program Element (SRPE) defines the knowledge gaps that impact our understanding of the cancer risks. These gaps are outlined in NASA's Human Research Roadmap [4], which identifies the research questions and actions recommended for reducing the uncertainty in the current NSCR model and for formulation of future models. The greatest contributors to uncertainty in the current model include radiation quality, dose rate effects, and the transfer of exposure-based risk from other populations to an astronaut population. Future formulations of the risk model may benefit from including other potential sources of uncertainty such as space dosimetry, errors in human epidemiology data, and the impact of microgravity and other spaceflight stressors. Here, we discuss the current capabilities of the NSCR-2012 model and several immediate research needs, highlighting areas expected to have an operational impact on the current model schema. The following subway-style route map outlines the NSCR-2012 model (Green Line), emphasizing the research gaps in the Human Research Roadmap for risk of radiation-induced carcinogenesis (Stops on Dashed Lines). The map diagrams how these research gaps feed specific portions of the model.
Various robotic tooling options have been evaluated for the NRIC DOME concept of operations (ConOps). Framatome was contracted to develop a wide-ranging list of commercial off the shelf (COTS) and custom robotic systems to be considered for performing the DOME ConOps functions. Subsequent project tasks from Framatome narrowed down the list and scored the most viable options. The abbreviated list, and associated scoring, has been reviewed and assessed to provide formal recommendations for the robotic ConOps functions of DOME. The overhead telescoping mast & Kraft arm assembly is recommended as the primary system for reactor demobilization and removal. The estimated cost is $\$700$K with a timeline to develop and deliver of about 2.5 years. The mast & Kraft arm would still require an overhead lift system for mobilization and installation. Either the refurbished polar crane or a new gantry crane delivery platform could both serve as the overhead lift and delivery system. The estimated costs for the refurbishment polar crane and new gantry crane systems are, respectively, $\$4.4$M and $\$3$M with about 2.5 years to develop and deliver. A Brokk + Kraft crawler & arm is recommended as a secondary robotic system to support the overhead mast & Kraft arm system. The Brokk + Kraft crawler & arm would cost an estimated $\$726$k and would take about 1.5 years to develop and deliver. The Boston Dynamics SPOT robot is also recommended for the in-service monitoring during experimentation operations. The estimated cost is $\$220$K with a timeline to deliver of 8-14 months. The Elios 3 aerial drone is recommended to perform large area radiation dose rate mapping and visual inspections. The estimated cost is a $\$100$K and will also need about 8-14 months to develop and deliver. A mockup rig is also recommended to be procured an employed to test & verify the robotic capabilities as well as provide needed training for operations personnel. It is estimated that a mockup rig would cost about $\$500$k and would take up to a year to develop and build.
Mission and vehicle integration tradeoffs involving the use of the pellet bed reactor (PBR) for nuclear powered vehicles is discussed, with much of the information being given in viewgraph form. Information is given on propellant tank geometries, shield weight requirements for conventional tank configurations, effective specific impulse, radiation mapping, radiation dose rate after shutdown, space transfer vehicle design data, a Mars mission summary, sample pellet bed nuclear orbit transfer vehicle mass breakdown, and payload fraction vs. velocity increment.
A major health risk for human deep space exploration is central nervous system (CNS) damage by ionizing radiation. Simulated galactic cosmic rays or their components, especially high-linear energy transfer particles such as 56Fe ions, have been shown to cause CNS damage, neuroinflammation and cognitive dysfunction in rodent models, but their effects on human CNS remain to be investigated. CNS damage from any insult, including ionizing radiation, is partially mediated by the blood-brain barrier (BBB), which regulates interactions between CNS and the rest of the body. Astrocytes are major cellular regulators of BBB permeability and also modulate neuroinflammation and neurodegeneration. However, BBB and astrocyte functions in regulating CNS responses to space radiation remain little investigated, especially in human organ analogs. Therefore, we developed and utilized a high-throughput 3D human neurovascular organ-on-a-chip model, seeded with induced pluripotent stem cell-derived cells. The effects of time course, ionizing radiation dose and dose rate were mapped by exposing the model to either acute, high dose rate radiation with simulated galactic cosmic rays or 600 MeV/n 56Fe particles, or protracted, low dose rate gamma radiation using a 57Co sealed source setup. We investigated BBB permeability, oxidative stress, cellular damage and secreted factors over the time period between 24 hours – 2 weeks after 0.1 – 0.8 Gy irradiation. We observed that ionizing radiation exposure increased BBB permeability, caused oxidative stress, damaged endothelial cells and altered expression of inflammatory cytokines with a subset of outcomes dependent on ionizing radiation dose rate. Furthermore, our results indicated that astrocyte functions were primarily deleterious at early time points and protective later after irradiation, resembling CNS responses to injury in vivo. Our findings in organ models were complemented by studies on true spaceflight using mouse spatial and single cell multi-omics, which similarly indicated spaceflight-mediated changes in astrocyte functions. In summary, our study evaluates the regulation of neurovascular responses to simulated space radiation, suggesting astrocytes as targets for countermeasures to mitigate CNS damage in deep space exploration.