Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mutations induced in Tradescantia by small doses of X-rays and neutrons - Analysis of dose-response curves.

Dose-response curves for pink somatic mutations in Tradescantia stamen hairs were analyzed after neutron and X-ray irradiation with doses ranging from a fraction of a rad to the region of saturation. The dose-effect relation for neutrons indicates a linear dependence from 0.01 to 8 rads; between 0.25 and 5 rads, a linear dependence is indicated for X-rays also. As a consequence the relative biological effectiveness reaches a constant value (about 50) at low doses. The observations are in good agreement with the predictions of the theory of dual radiation action and support its interpretation of the effects of radiation on higher organisms. The doubling dose of X-rays was found to be nearly 1 rad.

Sparrow, A. H.↗

The effect of modeling dose uncertainty on low-boom community noise dose-response curves

In logistic dose-response modeling, failing to account for uncertainty in estimated doses can cause an artificial flattening or attenuation of the slope of the summary curve. In Lee et al. [J. Acoust. Soc. Am. 147(4), pp. 2222-2234 (2020)], data from two NASA low-amplitude sonic boom community noise survey tests were modeled using a Bayesian multilevel logistic regression (MLR) statistical model that assumed there was no uncertainty in the noise dose estimates. However, in these community tests, the noise dose uncertainty was estimated by Page et al. [NASA/CR-2014-218180 and NASA/CR-2020-220589/Volume I] using a leave-one-out method. In the current work, a term was added to extend the Bayesian MLR model to account for the estimated noise dose uncertainty quantified in the Page et al. analyses. This uncertainty term was included in two ways, either as classical or as Berkson uncertainty, and yield similar results. When the uncertainty is accounted for in the Bayesian MLR model, the dose-response curves become 5-10% steeper, but the difference in the noise dose that elicits a 5% highly annoyed response is small (less than 1 dB). This result is encouraging for future X-59 community tests whose survey area will be sparsely populated with noise monitors.

X-59↗

Dose-response relationship for light intensity and ocular and electroencephalographic correlates of human alertness

Light can elicit both circadian and acute physiological responses in humans. In a dose response protocol men and women were exposed to illuminances ranging from 3 to 9100 lux for 6.5 h during the early biological night after they had been exposed to <3 lux for several hours. Light exerted an acute alerting response as assessed by a reduction in the incidence of slow-eye movements, a reduction of EEG activity in the theta-alpha frequencies (power density in the 5-9 Hz range) as well as a reduction in self-reported sleepiness. This alerting response was positively correlated with the degree of melatonin suppression by light. In accordance with the dose response function for circadian resetting and melatonin suppression, the responses of all three indices of alertness to variations in illuminance were consistent with a logistic dose response curve. Half of the maximum alerting response to bright light of 9100 lux was obtained with room light of approximately 100 lux. This sensitivity to light indicates that variations in illuminance within the range of typical, ambient, room light (90-180 lux) can have a significant impact on subjective alertness and its electrophysiologic concomitants in humans during the early biological night.

Clinical Trial↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-Response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗

Modeling Measurement Error in Dose-Response Models of Community Annoyance to Low-Noise Supersonic Flight

The primary research goal of the forthcoming NASA Quesst mission community test campaign is to collect representative community response data in support of the development of supersonic overflight noise certification standards. Beginning in 2026, NASA will fly the novel X-59 demonstrator aircraft over select communities in United States in order to demonstrate the possibility of low-noise supersonic flight over land and to collect objective measurements and subjective data on the perceptual experience of this new noise source. It is believed that a regression of a binary perceptual response (‘highly annoyed’ or ‘not’) on estimated noise levels (doses, measured in decibels) will provide a useful dose-response relationship for regulators. However, as these estimated doses will be subject to measurement error, naïve estimators of regression coefficients are inconsistent and slopes may be subject to attenuation bias. In this presentation, I contrast functional modeling of measurement error via simulation extrapolation (SIMEX) with structural Bayesian measurement error models. These methods are applied to available data collected during two NASA risk reduction studies in California in 2011 and Texas in 2018. I’ll conclude noting that in the presence of nonnegligible measurement errors, probabilities of annoyance may be overpredicted for low noise levels and underpredicted for high noise levels, therefore, methods of correcting for measurement error will be necessary to improve the utility of the dose-response relationship for policy-making purposes.

simulation↗

Comparison of Two Statistical Models for Low Boom Dose-response Relationships with Correlated Responses

This study compares two statistical models to construct summary dose-response curves for low boom community noise surveys. Data from two NASA field surveys are used that consist of multiple responses per survey participant. These data require an approach that accounts for the correlation among repeated annoyance observations from the same participant. A multilevel model accounts for the correlation by allowing estimated parameters to vary with each survey participant. On the other hand, a population average model utilizes generalized estimating equations and accounts for the correlation via a userspecified within-subject correlation structure. A visual comparison of the dose-response curves for these two methods reveals similar results. When comparing specific points along the summary curves, the multilevel model yields more precise confidence bounds than the population average model. The similarity between the summary curves derived from each model lends validity to both approaches for approximating a population representative summary curve, though modeling assumptions may lend favor to the multilevel logistic modeling approach over the population average model.

dose-response↗

Dose Error Correction Using Simulation Extrapolation for Community Noise Dose-Response Modeling

The objective of this work is to provide a framework to account and correct for dose error in dose-response modeling due to measurement uncertainty. Error in noise measurements, especially in the case of limited monitoring locations in a community, can lead to an attenuation or misestimation of parameters in dose-response models. This error can result in overpredicted annoyance at lower doses and underpredicted annoyance at higher doses. Simulated data in the present work are based on previous NASA community studies and incorporate a notional design for future studies with the X-59 aircraft. Several populations of different annoyance response sensitivities are included. Simulation extrapolation (SIMEX, Cook and Stefanski 1994) is used to correct for the dose error in a simple, fully pooled logistic regression. Results indicate the negative impact of attenuation is greatly diminished for all amounts of dose error considered, regardless of a population’s annoyance sensitivity. Therefore, SIMEX can help produce a more accurate dose-response relationship.

SIMEX↗

Comparing Two Statistical Models for Low Boom Dose-response Relationships with Correlated Responses

This study compares two statistical modeling approaches to construct summary dose-response curves for low boom community noise surveys. NASA field survey data were used that consist of multiple responses from a survey participant. These data require an approach that accounts for the correlation among repeated annoyance observations from the same participant. A multilevel model accounts for the correlation by allowing estimated parameters to vary with each survey participant. On the other hand, a population average model utilizes generalized estimating equations and accounts for the correlation via a user-specified within-subject correlation structure. A visual comparison of the dose-response curves for these two methods reveals similar results. When comparing specific points along the summary curves, the multilevel model yields more precise confidence bounds than the population average model. The similarity between the summary curves derived from each model lends validity to both approaches for approximating a population representative summary curve.

X-59↗

Accounting for Dose Uncertainty in Dose-Response Curve Estimation Using Hierarchical Bayes Models

As part of their development of the technology for low-boom supersonic flight, the National Aeronautics and Space Administration (NASA) is planning to conduct a set of supersonic aircraft annoyance surveys in select communities in the United States, to measure public perception of the reduced sonic boom. The relationship between a noise exposure level of a supersonic flight event and the probability of an individual being highly annoyed by the event is quantified by a dose-response curve, which is usually based on logistic regression modeling. Unavoidable amounts of estimation error are expected in the upcoming noise measurements, which can bias the results of the logistic regression if ignored. Hence, the development of an estimation approach that accounts for such error when estimating the dose-response curve is imperative. In this paper, an evaluation study is conducted to assess the impact of measurement error on dose-response curve estimation. For this, hierarchical Bayes models using different specifications are fit to data collected by NASA in 2018, as part of a risk-reduction study of supersonic flights affecting Galveston, Texas. It is observed that the estimated dose-response curve appears sensitive to uncertainty in dose measurements, being subject to attenuation bias.

community response↗

Evaluation of the Emergency Response Dose Assessment System(ERDAS)

The emergency response dose assessment system (ERDAS) is a protype software and hardware system configured to produce routine mesoscale meteorological forecasts and enhanced dispersion estimates on an operational basis for the Kennedy Space Center (KSC)/Cape Canaveral Air Station (CCAS) region. ERDAS provides emergency response guidance to operations at KSC/CCAS in the case of an accidental hazardous material release or an aborted vehicle launch. This report describes the evaluation of ERDAS including: evaluation of sea breeze predictions, comparison of launch plume location and concentration predictions, case study of a toxic release, evaluation of model sensitivity to varying input parameters, evaluation of the user interface, assessment of ERDA's operational capabilities, and a comparison of ERDAS models to the ocean breeze dry gultch diffusion model.

Evans, Randolph J.↗

Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts After Exposure to Very Low Dose of High Let Radiation

The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivor with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (0.01 - 0.20 Gy) of 170 MeV/u Si-28 ions or 600 MeV/u Fe-56 ions, including doses where on average less than one direct ion traversal per cell nucleus occurs. Chromosomes were analyzed using the whole-chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). The responses for doses above 0.1 Gy (more than one ion traverses a cell) showed linear dose responses. However, for doses less than 0.1 Gy, both Si-28 ions and Fe-56 ions showed a dose independent response above background chromosome aberrations frequencies. Possible explanations for our results are non-targeted effects due to aberrant cell signaling [1], or delta-ray dose fluctuations [2] where a fraction of cells receive significant delta-ray doses due to the contributions of multiple ion tracks that do not directly traverse cell nuclei where chromosome aberrations are scored.

Hada, M.↗

Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

Hada, M.↗

Heavy particle irradiation, neurochemistry and behavior: thresholds, dose-response curves and recovery of function

Exposure to heavy particles can affect the functioning of the central nervous system (CNS), particularly the dopaminergic system. In turn, the radiation-induced disruption of dopaminergic function affects a variety of behaviors that are dependent upon the integrity of this system, including motor behavior (upper body strength), amphetamine (dopamine)-mediated taste aversion learning, and operant conditioning (fixed-ratio bar pressing). Although the relationships between heavy particle irradiation and the effects of exposure depend, to some extent, upon the specific behavioral or neurochemical endpoint under consideration, a review of the available research leads to the hypothesis that the endpoints mediated by the CNS have certain characteristics in common. These include: (1) a threshold, below which there is no apparent effect; (2) the lack of a dose-response relationship, or an extremely steep dose-response curve, depending on the particular endpoint; and (3) the absence of recovery of function, such that the heavy particle-induced behavioral and neural changes are present when tested up to one year following exposure. The current report reviews the data relevant to the degree to which these characteristics are common to neurochemical and behavioral endpoints that are mediated by the effects of exposure to heavy particles on CNS activity. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Review↗

Dose-Response Data Collection Preparation for the NASA Quesst Mission With the X-59

Supersonic flight has the potential to cut travel times in half; however, community annoyance to sonic booms led to the ban on overland commercial supersonic flight by the Federal Aviation Administration in 1973. As part of its Quesst mission, NASA is developing the X-59 aircraft to demonstrate quiet supersonic flight and collect dose-response data to inform regulators in their efforts to establish noise standards to replace the current supersonic speed limit. This talk presents an overview of the NASA Quesst mission and poses some challenges in collecting and analyzing X-59 dose-response data. For the upcoming community flight campaign, the noise dose is the loudness of a supersonic overflight of the X-59 and the perceptual response from participants is captured via surveys after the flyover events. Establishing a relationship between noise dose and perceptual response will be a key product of these efforts.

X-59↗

Oxidative Stress and Neuroconsequences of the Spaceflight Environment –A 5-ion GCRsim Dose-response Study

The overall scope of this project is to test the hypothesis that Ionizing Radiation (IR), microgravity and social isolation combine synergistically to trigger an oxidative stress response that alters immune homeostasis, brain structure/function, and neurobehavioral/cognitive performance. Specific Aims for this project are to: (1) Determine dose-response curves for acute ‘Five-Ion GCR Simulation’ exposure for immune, brain and performance responses in crew age-matched adult male and female mice; (2) Determine effects of acute ‘Five-Ion GCR Simulation’ exposure singly and in combination with simulated microgravity and social isolation, on immune, brain and performance responses in crew age-matched male and female mice mimicking deep space missions; and (3) Determine efficacy of the dietary antioxidant, Nicotinamide Mononucleotide (NMN), a key intermediate in nicotinamide adenine dinucleotide (NAD+) biosynthesis. Here we exposed mature (23-24-week-old) male and female mice to simulated 5-Ion GCR (either 0, 5, 15, or 50cGy) at the NASA Space Radiation Laboratory (NSRL). Across ‘Acute’ (IR+72hrs and IR+14 days) and ‘Delayed’ (IR+28 to IR+124 days) phases of the 6-month-long study, we assessed immune, neural, and functional (sensorimotor/behavioral/cognitive) responses anticipated during a transit to Mars. This presentation will report on dose-response curves for 5-ion GCRsim related to potential biomarkers; structural/functional changes in the immune and nervous systems; and behavioral/cognitive performance deficits. This project addresses NASA’s efforts to characterize risks and identify appropriate countermeasures in anticipation of future deep space missions. Ensuring crew health and performance during extended transits necessitates that sensorimotor and cognitive abilities remain strong to avoid potentially catastrophic health and safety outcomes.

deep space↗