Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Regulatory Considerations for Domestic Reprocessing Facility Physical Security

U.S. advanced non-light-water reactor vendors may pursue collocated on-site reprocessing activities. Therefore, these facilities are likely to possess formula quantities, or Category I quantities, of special nuclear material (SNM) during normal operations. The U.S. Nuclear Regulatory Commission (U.S. NRC) has yet to formally establish a regulatory framework for commercial reprocessing. While Category I requirements would explicitly not apply in this circumstance under current regulatory requirements, regulatory certainty does not exist. A novel framework should be developed to ensure public health and safety while also risk-informing the physical security requirements. This report reviews the relevant background of related rulemaking activities and proposes risk-informed physical protection requirements to satisfy these objectives. Insights from NRC security-related rulemaking activities provide a substantial technical basis to approach potential establishment of physical security requirements for reprocessing facilities. If a licensee can provide justification that the material satisfies a sufficient self-protecting radiation dose threshold, the material may not be subject to theft or diversion requirements and only potential sabotage requirements would apply. Furthermore, if the material can be justified to be moderately dilute, a set of risk-informed requirements could provide adequate protection of public health and safety. A revised performance objective for prevention of theft of moderately dilute Category I SNM may be detection to allow prompt recovery by a local law enforcement agency. However, a significant caveat to the proposed categorization scheme is the unknown integration of radiological sabotage with requirements for the protection against theft. Future licensees should consult with the NRC regarding treatment of this regulatory topic. Additionally, the self-protecting radiation dose threshold (either the existing or a proposed future threshold) would need to be considered. An integrated approach may apply graded potential requirements for protection against the design basis threat of radiological sabotage currently applicable to commercial nuclear power plants and Category I SNM facilities defined within 10 CFR 73.1(a).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-DNA radiosensitive targets that initiate persistent behavioral deficits in rats exposed to space radiation

Predicting future CNS risks for astronauts during deep-space missions will rely substantially on ground-based rodent data with space-relevant ions and behaviors. For rats, the accumulated evidence indicates that less densely ionizing radiation, such as 4 He and 12 C ions, induce behavior deficits at lower doses than densely ionizing ions, such as 48 Ti and 56 Fe. However, this observation conflicts with standard somatic radiobiology, in which densely ionizing ions are generally more effective than less densely ionizing ions, and where the DNA/nucleus is the accepted target for radiation-induced tumorigenesis, cytogenetic aberrations, genetic mutations, and reproductive cell death. To gain deeper insight into the subcellular nature of the radiation targets for behavior risks, we compared the effects of dose, fluence, and linear energy transfer (LET) of 4 He and 56 Fe particles using existing datasets for four distinct behavioral outcomes in rats: elevated plus maze (EPM-anxiety), novel object recognition (NOR-memory), operant responding (OR-response to environmental stimuli), and attentional set-shifting (ATSET-cognitive flexibility). We confirmed that less densely ionizing particles (except protons) showed ~100-fold lower threshold doses than densely ionizing particles for behavioral deficits (0.1–1 cGy for 4 He vs. 15–100 cGy for 56 Fe). However, when analyzed by fluence the behavioral responses converged, indicating that 4 He and 56 Fe were equally effective on a per-track basis. When analyzed by LET, there were ~100-fold differences in the LET for maximum effectiveness for behavioral deficits and DNA endpoints (~1 vs ~100 keV/μm, respectively). These unique features of radiation-induced behavioral deficits (high sensitivity to particles in the 1-keV/μm range, insensitivity to protons in the 0.2 keV/μm range, and isofluence dependence for particles with LET>1 keV/μm) provide evidence in support of a new hypothesis of sub-micron sized radiosensitive targets for behavioral effects consistent with the thickness of plasma membranes and/or small subcellular structures, smaller than a whole synapse. Like our behavior findings, mouse immature oocyte killing which is known to have a plasma membrane target was also better explained by fluence, rather than dose. In contrast, fluence analyses for DNA/nuclear endpoints in somatic cells (e.g., tumor induction, chromosome aberrations) showed opposite results, suggesting that behavior targets are not DNA. Our findings raise questions regarding the identity of subcellular targets and the multi-cellular functional unit for behavior risks, low-dose susceptibility, and generalizability from rat to other species and astronauts.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

In Situ Formation of Ripplocations in Hybrid Organic–Inorganic MXenes

Abstract Inorganic–organic hybrid MXenes (h‐MXenes) are a family of 2D transition metal carbides and nitrides functionalized with alkylimido and alkylamido surface groups. Using cryogenic and room temperature scanning transmission electron microscopy (STEM) and electron energy‐loss spectroscopy (EELS), it is shown that ripplocations, a form of a fundamental defect in 2D and layered structures, are abundant in this family of materials. Furthermore, detailed studies of electron probe sample interactions, focusing on structural deformations caused by the electron beam are presented. The findings indicate that at cryogenic temperatures (≈100 K) and below a specific dose threshold, the structure of h‐MXenes remains largely intact. However, exceeding this threshold leads to electron beam‐induced deformation through ripplocations. Interestingly, the deformation behavior, required dose, and resultant structure are highly dependent on temperature. At 100 K, it is demonstrated that the electron beam can induce ripplocations in situ with a high degree of precision.

Chemistry↗

Non-thermal structural transformation of diamond driven by x-rays

Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

TCAD-Machine Learning Enabled TID Compact Model Development for Commercial SiC MOSFET

We propose a TCAD (Technology Computer Aided Design)-machine learning coupled approach that combines a TCAD tool (Charon), optimization/uncertainty quantification tool (Dakota), surrogate models, and Bayesian learning capabilities. The coupling approach is used for accurate modeling and calibration of total ionizing dose (TID) induced threshold voltage (V th ) shifts in Commercial-Off-The-Shelf (COTS) semiconductor devices and to develop physics-informed TID compact models. This versatile approach is applied to model the TID effect in an exemplar COTS 3.3 kV SiC power MOSFET (Metal-Oxide-Semiconductor Field-Effect Transistor). With the Charon-Dakota coupling, we can determine key device geometry and doping values based on device physics, which are difficult to obtain or not available for COTS devices but important for TCAD simulation; additionally, we can efficiently generate thousands of simulation results in a large parameter space, which makes it possible to develop data-driven surrogate models and perform Bayesian calibration. Utilizing the full tool-coupling approach, we achieve calibrated TCAD simulation models that accurately capture the average TID-induced V th shifts behavior with total doses and V th shifts saturation at high doses as observed in experimental data. More importantly, the calibrated TCAD simulations are obtained with determined TID model parameters (e.g., hole trap density and capture cross section) values that contain well quantified uncertainties. Furthermore, we can isolate and quantify the noises that are not captured by the TCAD models but exist in the measured data due to measurements and devices variabilities. Lastly, the calibrated surrogate models are used to develop physics-informed TID compact models. The method is generalizable to other devices and/or radiation conditions with few modifications and can provide well-determined uncertainties.

COTS↗

Estimation Methodology to Evaluate Hypothetical Downwind Impacts from Fusion Plants

The continuing move toward establishing fusion systems for power generation and the associated research to that end is prompting examination of the potential health and safety impacts of such plants to the environment and human health. As many fusion facilities will have tritium inventories on site as part of the fusion fuel, evaluating the potential for downwind impacts from fusion facilities or power plants resulting from accident or routine emissions is a general requirement for assessing location and impacts to workers and the public. As part of siting considerations and permitting, the fusion facilities would be evaluated for potential for downwind concentration and dose impacts. For accident assessment scenarios, the downwind impacts are usually modeled as an instantaneous (or near-instantaneous) release of material transported following the wind. A range of meteorological conditions are usually assessed to determine a bounding case which results in a dose exceeding a specified threshold (e.g., 95 th or 99 th percentile; DOE 2015). This report provides initial estimates of the downwind dose impacts from a potential tritium release at a fusion power plant-relevant facility and identifies potential distances required to limit impacts to nearby population. This effort is meant to provide a bounding analysis and theoretical understanding of impacts of tritium releases for facilities subject to various environmental and atmospheric conditions. Using a Gaussian dispersion model to simulate a brief plume, downwind concentration and dose is projected for tritium oxide. Releases are assumed to consist entirely of tritium oxide due to the increased dose impacts from the oxide form relative to the elemental form of tritium. We also briefly identify how climatological conditions could potentially be used to support risk profile determination.

54 ENVIRONMENTAL SCIENCES↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

URC/HRC Selection Guidance

Given the importance of the URC and HRC thresholds as part of a physical security program that is designed to protect against radiological sabotage, it is important to provide guidance on how to assign those thresholds consistent with a State’s level of risk tolerance. Without such guidance, most States will be challenged to establish appropriate thresholds or appropriately establish regulations. This document provides guidance on establishing dose limits and where they apply, as well as the timeframe for which the dose limits should be measured. For dose limits, it offers examples of established thresholds based on safety and emergency response thresholds. Whereas, for timeframes, a process to identify possible timeframes is offered.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Impact of amorphous pockets on displacement damage evolution in silicon

Silicon has long been known to exhibit amorphization in response to heavy particle bombardment. For doses below the total amorphization threshold, partial amorphization is observed in the form of scattered amorphous pockets. While extensive research has gone into modeling the formation and evolution of amorphous pockets in response to irradiation, no studies yet investigate their impact on the evolution of other damage such as interstitial supersaturation and clustering. In this study, we survey the impact of amorphous pockets on defect evolution in silicon when treated as static sinks. MD is first used to show that amorphous pockets provide energetically favorable sites for point defects relative to the crystalline bulk, supporting the hypothesis that they act as sinks. A 0-D cluster dynamics model is then constructed, taking an interstitial clustering model from the literature and including amorphous pockets as a sink species. We conduct our survey for temperatures between 30 and 400 °C and sink strengths between 1 to 6 x 10 10 cm −2 . Both implantation- and radiation-induced damage states are investigated using interstitial and vacancy concentrations as initial condition variables. We find that, due to the differing migration rates of the interstitial and the vacancy, amorphous pockets have a non-monotonic impact on the final damage state depending on the effective sink strength of the amorphous pockets, resulting in increased damage formation in regimes of intermediate amorphization. In conclusion, this result emphasizes the important role of amorphous pockets in governing the evolution of damage in partially amorphized crystalline materials.

36 MATERIALS SCIENCE↗

Integrated Security-Safety Consequence Study of a Heat Pipe Reactor

This report presents a preliminary demonstration of integrated security/safety consequence modeling to support potential physical security exemption justifications under the new Title 10 Code of Federal Regulations Part 53 licensing pathway, which allows exemptions if sabotage-induced radiological consequences do not exceed 25 rem at the site boundary two hours after release without mitigative actions. A hypothetical heat pipe microreactor subjected to direct sabotage by a 150 lbs. TNT-equivalent high-explosive device was analyzed using a simplified radionuclide release estimate based on DOE-HDBK-3010-94, implemented in the MELCOR severe accident analysis code to model release transport and attenuation through reactor/building compartments, with MELCOR outputs coupled to MACCS to compute offsite doses and the distance-to-threshold metric D 25rem . Six scenarios were evaluated to examine sensitivities to release pathway/building configuration and radionuclide form (vapor versus aerosols with different size distributions). Results show a positive correlation between leak path factor and D 25rem and indicate that reactor building compartmentalization can substantially reduce consequences (a single-story configuration reduced D 25rem by roughly an order of magnitude relative to a cavity-only configuration), while vapor versus aerosol assumptions had limited impact for the modeled two-story case on the spatial grid used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Psychosomatic Bias in Low-dose Radiation Epidemiology: Assessing the Role of Radiophobia and Stress in Cancer Incidence

Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025

Environmental Sciences & Ecology↗

The Effects of Threshold Voltage and Number of Fins per Transistor on the TID Response of GF 12LP Technology

This abstract presents a comprehensive analysis of total ionizing dose (TID) response in GlobalFoundries’ 12LP 12nm bulk FinFET technology using 10keV X-rays. Devices with higher threshold voltages (VTs) demonstrated lower increases in off-state leakage current (IDS,OFF) post-irradiation, highlighting the mitigating role of high VT in TID response. Our data shows that transistors with fewer fins exhibit superior TID resistance, implying lower susceptibility to radiation effects. Our study also probed two bias conditions, "Gate-On" and "Pass-Gate," with the former displaying more severe TID degradation. Interestingly, p-type devices displayed negligible degradation, underscoring their inherent resilience to TID effects. Additionally, medium thick n-type devices echoed the fin-count-dependent TID response observed in other transistor types, further strengthening our findings. These results underscore the importance of strategic transistor selection and design for enhancing the TID resilience of future CMOS FinFET architectures, particularly critical in radiation-intense environments.

42 ENGINEERING↗

Impact of 12-nm FinFET Technology Variations on TID Effects: A Comparative Study of GF 12LP and 12LP+ at the Transistor Level

Here, this article presents a comparative analysis of total ionizing dose (TID) response in GlobalFoundries’ (GF) 12 low-power (LP) and 12LP+12-nm bulk fin field effect transistor (FinFET) technologies using 10-keV X-rays. Our findings show that 12LP+ n-type transistors demonstrate higher sensitivity to TID degradation of the off-state leakage drain current compared to 12LP. Data indicate that for both 12LP and 12LP+, transistors with higher threshold voltages (VTs) exhibit lower off-state drain-source leakage postirradiation compared to transistors with lower VTs. Data consistently show that transistors with fewer fins per transistor show superior TID tolerance, in both 12LP and 12LP+ technologies. Lower VT transistors in both technologies display similar preirradiation leakage currents. On the other hand, higher VT transistors in 12LP+ show lower preirradiation leakage currents than those in 12LP, highlighting that the front-end-of-line of 12LP+ technology has been modified compared to 12LP. p-type devices in 12LP+ presented negligible degradation. Larger TID sensitivity in 12LP+ might be attributed to the implementation of dual-metal gate work functions, reduced halo doping, deeper source/drain (S/D) doping profiles, and/or 12LP+ having narrower fins compared to 12LP.

Dual-metal gate work functions↗