Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dosimetry for Advanced Reactors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175C: Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 175C

Results of neutron dosimetry measurements in ATR for cycle 175C are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accurate Dosimetry for Future Advanced Reactor Deployment and Operation

Accurate Dosimetry for Future Advanced Reactor Deployment and Operation from a customer's perspective. The main discussion points will be why we should be interested in this topic of nuclear renaissance, practical examples, and Dosimetry's role in advance reactor operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Test Reactor Neutron Dosimetry Report - 173B (Rev. 1)

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175B-1

Results of neutron dosimetry measurements in ATR for cycle 175B-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175B↗

Advanced Test Reactor Neutron Dosimetry Report - 173B

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B↗

Advanced Test Reactor Neutron Dosimetry Report

Results of neutron dosimetry measurements in ATR for cycle 173A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173A↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175A-1

Results of neutron dosimetry measurements in ATR for cycle 175A-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175A↗

Advancements in PTFE/EPR Reactor Dosimetry

Discussion of current efforts by Radiation Metrology Laboratory at Sandia to continue development and deployment of an EPR/PTFE dosimetry system.

Vehar, David W. [Sandia National Laboratories (SNL↗

Advanced Test Reactor Neutron Dosimetry Report – 174 A & B

Results of neutron dosimetry measurements in ATR for cycle 174 A B are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 172A-1

Results of neutron dosimetry measurements in ATR for cycle 172A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

172A↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 173-C

Results of neutron dosimetry measurements in ATR for cycle 173-C are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out [Slides]

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

In-Canal Assay of High Specific Activity 60 Co at the Advanced Test Reactor

Production of high specific activity (HSA) 60 Co has recently resumed at the Advanced Test Reactor (ATR) at the Idaho National Laboratory. The technical steps of performing in-canal assay of HSA 60 Co targets at the ATR are described herein. The HSA targets are assayed on a regular basis, between cycles at the ATR, in order to assess the progress of activation. The targets are also assayed at the conclusion of the irradiation in order to provide activity estimates for the distributor and to be used for safety and shipping evaluations. These target assay activities must take place in the ATR canal to provide sufficient radiological shielding. Furthermore, a specialized assay fixture is used in conjunction with custom 60 Co radiation standards to assess the irradiated target. The specific activity of each irradiated target was determined by first measuring the 60 Co standards to determine a sensitivity factor. Then, each irradiated target was measured, and the integrated measurement was multiplied by the sensitivity factor to determine the total activity of the irradiated target. Finally, a correction factor was determined to adjust the reported activity, accounting for differences in the physical geometries of the standards and targets. These methods were used to accurately assay the gross activity of nine irradiated 60 Co targets, two of which were delivered to the distributor where confirmatory hot-cell assays were performed verifying the accuracy of the in-canal assay method.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗