Wind Tunnel PSD and MVD Characterization Using New 1D2D Optical Array Probes

This work explores characterization of the liquid clouds using a combination of a forward scattering probe and two Optical Array Probes. Current OAP probes provide particle shape, size, and number concentration from two-dimensional shadow images. However, past studies have shown that such images are subject to distortion when outside of the focal plane. This affects the retrieval of particle size distributions, particularly in the Supercooled Large Droplet size range. In this article, the use of a Droplet Measurement Technologies Cloud Droplet Probe and two new OAPs produced by Science Engineering Associates, is examined using wind tunnel data, to assess suitability for use in a wind tunnel calibration in SLD conditions. The new OAP probes exploit a flexible and simple grey scale imaging method to eliminate some present shortcomings of commonly used OAPs, and to reduce correction factors. Spinning disk measurements were used to specify probe depth of field, and average size errors. Composite spectra covering the nominal 2-3200 µm size range were formed by crossing over from the CDP to 1D2D-X at 48 µm, and then to the 1D2D-Y at about 400 µm. A good overlap was found at the crossover points without any artificial scaling. Composite spectra adequately closed the liquid water content distribution, and provided integrated LWCs within about 35% of the hot-wire LWCs used for tunnel calibration. This discrepancy was at least partially attributed to LWC underestimation by the hot-wire at high MVD. A model of probe performance was used to show an example of expected accuracy of ideal probes subject to the same OAP distortions and using the same mitigating procedures and corrections, predicting PSD Median Volume Diameter and integrated LWC errors of less than 10%.

Aircraft Icing↗

Effect of vaporization on cryogenic spray dropsize measurement

The fluid mechanics of multi-phase flow breakup of liquid nitrogen, LN2, jets injected into sonic velocity nitrogen gasflow, was experimentally investigated. A scattered-light scanning instrument was used to measure the characteristic dropsize, D(sub v.5), of LN2 sprays and to determine the effect of droplet vaporization on experimental dropsize measurements. Under sonic gas-velocity conditions, liquid-jet breakup occurred in the regime of aerodynamic stripping. As a result, the following correlation of volume-median drop diameter, D(sub v.5), with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers; with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers; (D(sub v.5))(exp -1) = k(sub c)(W(sub g))(sup n), where proportionally constant k(sub c) and exponent n are functions of droplet vaporization rate. Partially vaporized sprays were investigated and it was found that n = 1.11, which is considerably less than the value of 1.33 that is predicted by atomization theory. This was attributed to the evaporative loss of very small droplets. As a result, the following expression was obtained experimentally: (D(sub v.5e))(exp -1) = 301(W(sub g))(sup 1.11). Values of D(sub v.5), that existed prior to partial vaporization of the LN2 sprays, were calculated and the following expression was derived for originally unvaporized LN2 sprays: (D(sub v.5))(exp -1) = 285(W(sub g))(sup 1.33). This expression agrees well with atomization theory that predicts n = 1.33, for liquid jet breakup in high-velocity gasflow.

Ingebo, Robert D.↗

Effect of vaporization on cryogenic spray dropsize measurement

The fluid mechanics of multi-phase flow breakup of liquid nitrogen, LN2, jets injected into sonic velocity nitrogen gasflow, was experimentally investigated. A scattered-light scanning instrument was used to measure the characteristic dropsize, D(sub v.5), of LN2 sprays and to determine the effect of droplet vaporization on experimental dropsize measurements. Under sonic gas-velocity conditions, liquid-jet breakup occurred in the regime of aerodynamic stripping. As a result, the following correlation of volume-median drop diameter, D(sub v.5), with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers: (D(sub v.5)) (exp -1) = k(sub c) (W(sub g)) (sup n), where proportionally constant k(sub c) and exponent n are functions of droplet vaporization rate. Partially vaporized sprays were investigated and it was found that n = 1.11, which is considerably less than the value of 1.33 that is predicted by atomization theory. This was attributed to the evaporative loss of very small droplets. As a result, the following expression was obtained experimentally: (D(sub v.5e)) (exp -1) = 301 (W(sub g)) (sub 1.11). Values of D(sub v.5), that existed prior to partial vaporization of the LN2 sprays, were calculated and the following expression was derived for originally unvaporized LN2 sprays: (D(sub v.5)) (exp -1) = 285 (W(sub g)) (sub 1.33). This expression agrees well with atomization theory that predicts n = 1.33, for liquid jet breakup in high-velocity gasflow.

Ingebo, Robert D.↗

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x=1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogrn gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x =1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogen gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

An experimental investigation of air-assist non-swirl atomizer sprays

Detailed measurements and comparisons were made of air-assist nonswirl atomizer sprays currently being used in aircraft icing research. The critical liquid to air mass flowrate ratio to achieve a good quality of atomization and the most suitable mean dropsize correlation equation has been determined. Two of the most sophisticated and effective instruments, the Laser Diffraction particle sizer (Malvern) and Phase/Doppler particle analyzer (Aerometrics), have been successfully employed in spray characterization over a wide range of operating conditions. Results obtained by line-of-sight measurements using the Laser Diffraction sizer are compared with point measurements obtained by using the Phase/Doppler analyzer as well as with photographs. The accuracy and limitations of using the various instruments for spray characterization are discussed.

Wang, Geng↗