Search NASA⌕ Search

SEARCH · Search NASA

Results for “Duv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Effects of Mars Analogue Dust Deposition on DUV Raman Spectra: Implications for the Mars2020 Perserverance Rover SHERLOC Instrument

The Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument suite includes a deep ultraviolet (DUV) Raman and fluorescence instrument on the robotic arm of the Mars2020 (M2020) Perseverance rover [1]. When sufficiently thick dust coatings are present, substrate surfaces are not detected, and mineralogical information not obtained. For example, the effect of palagonitic dust coatings as a function of depth to various substrates on thermal emission, VNIR, and Mössbauer spectra are reported by [2, 3]. In this study, we use the same palagonitic dust to study the effect of dust coating thickness on DUV Raman spectra.

N. C. Haney↗

The DUV Stability of Superlattice-Doped CMOS Detector Arrays

JPL and Alacron have recently developed a high performance, DUV camera with a superlattice doped CMOS imaging detector. Supperlattice doped detectors achieve nearly 100% internal quantum efficiency in the deep and far ultraviolet, and a single layer, Al2O3 antireflection coating enables 64% external quantum efficiency at 263nm. In lifetime tests performed at Applied Materials using 263 nm pulsed, solid state and 193 nm pulsed excimer laser, the quantum efficiency and dark current of the JPL/Alacron camera remained stable to better than 1% precision during long-term exposure to several billion laser pulses, with no measurable degradation, no blooming and no image memory at 1000 fps.

silicon detectors↗

Carbon Nanotube Scanning Probe for Surface Profiling of DUV and 193 nm Photoresist Pattern

The continual scaling down of semiconductors to 100 nm and below necessitates a characterization technique to resolve high aspect ratio features in the nanoscale regime. This paper reports the use of atomic force microscope coupled with high aspect ratio multi-walled carbon nanotube scanning probe tip for the purpose of imaging surface profile of photoresists. Multi-walled carbon nanotube tips used in this work are 5-10 nm in diameter and about a micron long. Their exceptional mechanical strength and ability to reversibly buckle enable to resolve steep, deep nanometer-scale features. Images of photoresist patterns generated by 257 nm interference lithography as well as 193 nm lithography are presented to demonstrate multi-walled carbon nanotube scanning probe tip for applications in metrology.

Nguyen, Cattien V.↗

The DUV Stability of Superlattice-Doped CMOS Detector Arrays

In this paper, we present experimental results and band structure calculations that illuminate the unique properties of superlattice-doped detectors. Numerical band structure calculations are presented to analyze the dependencies of surface passivation on dopant profiles and interface trap densities (Figure 3). Experiments and calculations show that quantum-engineered surfaces, grown at JPL by low temperature molecular beam epitaxy, achieve a qualitative as well as quantitative uniqueness in their near-immunity to high densities of surface and interface traps.

doped silicon surfaces↗

Relative Detectability of Iron-Bearing Phases for the Mars 2020 Sherloc Deep UV Raman Instrument: 1. Focusing on Carbonates

A deep ultraviolet (DUV) Raman and fluorescence instrument is a surface standoff instrument mounted on the robotic arm of the Mars 2020 (M2020) rover Perseverance, and it is a key element of the Scanning Habitable Environments with Luminescence for Organics and Chemicals (SHERLOC) investigation [1]. Measurement and science objectives include mineralogical and organic images (~100 μm/pixel) that map sub-millimeter spatial distributions and characterization of primary and secondary minerals, potential organics, and their interaction/alteration products. The results of data analysis pertain to understanding igneous and alteration processes on Mars through time, assessing habitability, evidencing in situ biosignatures, and, along with results from other Perseverance instruments, selecting samples to cache for Mars sample return. Acceptance of the SHERLOC investigation for the NASA M2020 mission [2] created a need for Mars-relevant DUV Raman spectra, particularly for inorganic materials [e.g., 3, 4]. As reported previously [e.g., 4, 5], phases with Fe cations as essential elements (e.g., siderite (FeCO3) and ankerite (FeCa(CO3)2) for carbonates) significantly hinder detection by DUV Raman because of intense absorption of incident and scattered DUV laser radiation by Fe cations. We report here the relative detectability of carbonates (Mg,Ca,Fe,Mn)CO3 by DUV Raman using a SHERLOC analog laboratory instrument.

R V Morris↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗

Implications of Deep UV Raman Spectra of Gypsum and Fe-Bearing Dust Mixtures for Gypsum Detectability by the SHERLOC M2020 Instrument

Key science objectives of the Mars2020 Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument suite include identification and characterization of inorganic and bio-logic phases and investigation of the past habitability of Jezero crater [1, 2]. To fully interpret in situ data received from SHERLOC, databases of deep ultraviolet (DUV) Raman spectra from a wide variety of martian analogue materials are being developed by us and others [e.g., 3]. Ferrous and ferric iron are abundant on the martian surface in bas-alt and, depending on alteration and transport processes, its alteration products. Fe-bearing phases are important to characterize with respect to detect-ability by DUV Raman spectroscopy because they strongly absorb DUV radiation, thereby decreasing Raman peak intensity [3, 4]. Ca-sulfates and Fe-bearing minerals have been commonly detected on the martian surface [5, 6]. In this analogue study, we collected Raman spectra of mechanical mixtures of powders of hematite HMS3 (~120 nm discrete particle diameter [7]), palagonite HWMK919 (<5 μm size fraction [8]) and gypsum WD163 (<150 μm size fraction) t o ex-amine the detectability of gypsum in the presence of relatively finer-grained, Fe bearing material. Be-cause of the difference in particle diameters, hematite and palagonite powders act as surrogates for martian dust, coating at small concentrations and then enveloping larger gypsum particles.

N C Haney↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

UV-B radiation amplification factor determined based on the simultaneous observation of total ozone and global spectral irradiance

The Japan Meteorological Agency started the spectral observation of solar ultraviolet (UV) irradiance on 1 January 1990 at Tateno, Aerological Observatory in Tsukuba (35 deg N, 140 deg E). The observation has been carried out using the Brewer spectrophotometer for the wavelengths from 290 to 325 nm with a 0.5 nm interval every hour from 30 minutes before sunrise to 30 minutes after sunset throughout a year. Because of remarkable similarity within observed spectra, an observed spectrum can be expressed by a simple combination of a reference spectrum and two parameters expressing the deformation of the observed spectrum from the reference. By use of the relation between one of the deformation parameters and the total ozone simultaneously observed with the Dobson spectrophotometer, the possible increase of UV irradiance due to ozone depletion is estimated. For damaging UV, the irradiance possibly increases about 19 percent with the ozone depletion of 10 percent at noon throughout the year in the northern midlatitudes. DUV at noon on the summer solstice possibly increases about 5.6 percent with the ozone depletion of 10 m atm-cm for all latitudes in the Northern Hemisphere.

Ito, T.↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Mapping Organic-Mineral Associations in Jezero crater

The search for potential signs of life on Mars, a primary aim of the Mars 2020 mission, is greatly informed by the detection of organic matter1. The presence of organic matter also provides key information about the habitability and biological potential of the planet throughout its history. The Perseverance rover was designed for in situ science with the ability to collect a suite of promising samples for eventual return to Earth. One of its instruments, Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC), is a deep ultraviolet (DUV) Raman and fluorescence spectrometer designed to map the distribution of organic molecules and minerals on rock surfaces at a resolution of 100 μm2. With its unique spectral mapping capabilities, SHERLOC enables a novel understanding of organic-mineral relationships on Mars to better determine their formation, deposition, and preservation mechanisms. The rover’s landing site within Jezero crater combines a high potential for past habitability as the site of an ancient lake basin with a diverse set of minerals, including carbonates and clays, that may preserve organic materials and potential biosignatures. The Jezero crater floor includes three formations (fm); two of these, Máaz and Séítah, were explored as part of the mission’s first campaign. Here, we report the detection of multiple species of aromatic organic molecules using Raman and fluorescence spectroscopy across ten targets in the two formations. This is the first evidence of organic molecules in Martian materials obtained using Raman spectroscopy, and among the first using fluorescence spectroscopy, beyond Earth3. We report specific spatial patterns and classes of organic molecules in these compositionally distinct formations, potentially indicating different fates of carbon in these environments. Our findings indicate that there is a diversity of aromatic molecules prevalent on the Martian surface and these materials persist despite exposure to surface conditions. These organic molecules are largely found within minerals linked to aqueous processes, suggesting that these processes may have had a key role in organic synthesis, transport from their point of origin, or preservation.

Sunanda Sharma↗

Luminescence Imager for Exploration

The Luminescence Imager for Exploration (LIfE) is an automated bright-field and epifluorescence microscope designed identify and characterize morphological and textural indicators of life and to identify, resolve, and characterize microscale structural features indicative of cells and cell fragments. To achieve these objectives, LIfE uses visible light to image organic and inorganic structures with submicron resolution, combined with, deep ultraviolet (DUV), ultraviolet (UV), and visible-light excitation for autofluorescence characterization of sample organic and mineral content. LIfE also autonomously manipulates samples to stain key molecular and structural indicators of microbial life (e.g., proteins, lipids, and nucleic acids) for fluorescence microscopic detection.

R C Quinn↗