Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic Scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Accurate quantification of lattice temperature dynamics from ultrafast electron diffraction of single-crystal films using dynamical scattering simulations

In ultrafast electron diffraction (UED) experiments, accurate retrieval of time-resolved structural parameters, such as atomic coordinates and thermal displacement parameters, requires an accurate scattering model. Unfortunately, kinematical models are often inaccurate even for relativistic electron probes, especially for dense, oriented single crystals where strong channeling and multiple scattering effects are present. This article introduces and demonstrates dynamical scattering models tailored for quantitative analysis of UED experiments performed on single-crystal films. As a case study, we examine ultrafast laser heating of single-crystal gold films. Comparison of kinematical and dynamical models reveals the strong effects of dynamical scattering within nm-scale films and their dependence on sample topography and probe kinetic energy. Applying to UED experiments on an 11 nm thick film using 750 keV electron probe pulses, the dynamical models provide a tenfold improvement over a comparable kinematical model in matching the measured UED patterns. Also, the retrieved lattice temperature rise is in very good agreement with predictions based on previously measured optical constants of gold, whereas fitting the Debye–Waller factor retrieves values that are more than three times lower. Altogether, these results show the importance of a dynamical scattering theory for quantitative analysis of UED and demonstrate models that can be practically applied to single-crystal materials and heterostructures.

36 MATERIALS SCIENCE↗

Quantification of Dynamic Scattering Effects in Molecular Crystals using Large Angle Rocking Beam Electron Diffraction

Electron crystallography provides a pathway to solve structure of small crystals (< 1um) in size, and thus overcomes difficult synthesis constraints involved in growing large crystals. Generally, electron diffraction data is collected in the form of integrated intensity using continuous rotation or by precession. The measured intensities in 3D are utilized for structure solution. Using this approach, structure solution of difficult crystals, such as small crystals of zeolites, metal-organic frameworks, molecular crystals, and proteins , can be solved by electron diffraction. However, electron structure solutions are regularly reported with higher Rvalues than x-ray or neutron diffraction. While similar structures are found despite the high R-values, the differences in the measure intensity and theory calculated intensity limit information that can be extracted by electron diffraction. Previous work demonstrated that including multiple-scattering effects significantly reduce the R-values . Thus, it is critical to be able to quantify the dynamical diffraction effects in molecular crystals.

Crystallography↗

Quantum Dynamics Scattering Study of AB+CDE Reactions: A Seven Dimensional Treatment for the H2+C2H Reaction

A time-dependent wave-packet approach is presented for the quantum dynamics study of the AB+CDE reaction system for zero total angular momentum. A seven-degree-of-freedom calculation is employed to study the chemical reaction of H2+C2H yields H + C2H2 by treating C2H as a linear molecule. Initial state selected reaction probabilities are presented for various initial ro-vibrational states. This study shows that vibrational excitation of H2 enhances the reaction probability, whereas the excitation of C2H has only a small effect on the reactivity. An integral cross section is also reported for the initial ground states of H2 and C2H. The theoretical and experimental results agree with each other very well when the calculated seven dimensional results are adjusted to account for the lower transition state barrier heights found in recent ab initio calculations.

Wang, Dunyou↗

3D strain field reconstruction by inversion of dynamical scattering

Strain governs not only the mechanical response of materials but also their electronic, optical, and catalytic properties. For this reason, the measurement of the 3D strain field is crucial for a detailed understanding and for further development of material properties through strain engineering. However, measuring strain variations along the electron beam direction has remained a major challenge for (scanning-) transmission electron microscopy (S/TEM). In this article, we present a method for 3D strain field determination using 4D-STEM. The method is based on the inversion of dynamical diffraction effects, which occur at strain field variations along the beam direction. We test the method against simulated data with a known ground truth and demonstrate its application to an experimental 4D-STEM dataset from an inclined pseudomorphically grown Al0.47Ga0.53N layer.

Niermann, Laura↗

Protection against UV and X-ray cataracts using dynamic light scattering

Static and dynamic light scattering (SLS and DLS) analysis was used to investigate the aggregation of lens proteins in a hyperbaric oxygen (HBO)/guinea pig in vivo model for nuclear cataract. Nuclear cataract, an opacity which occurs in the center of the lens, is a major type of human maturity-onset cataract for which the cause is not well-understood. HBO is commonly used in major hospitals for treating complications such as poor wound healing due to impaired blood circulation. It is known that treatment of human patients with HBO for extended periods of time can produce nuclear cataract. Guinea pigs, initially 18 months old, were treated with HBO (2.5 atm of 100% O2 for 2.5 hr) 3x per week for 7 months to increase tie level of lens nuclear light scattering. Age-matched animals were used for controls. The eyes of the animals were analyzed in vivo using an integrated static and DLS fiber optic probe in collaboration with the NASA group. DLS in vivo was used to measure the size of lens proteins at 50 different locations across the optical axis of the guinea pig lens.

Giblin, Frank J.↗

Interactions in Undersaturated and Supersaturated Lysozyme Solutions: Static and Dynamic Light Scattering Results

We have performed multiangle static and dynamic light scattering studies of lysozyme solutions at pH=4.7. The Rayleigh ratio R(sub g) and the collective diffusion coefficient D(sub c) were determined as function of both protein concentration c(sub p) and salt concentration c(sub s) with two different salts. At low salt concentrations, the scattering ratio K(sub c)(sub p)/R(sub theta) and diffusivity increased with protein concentration above the values for a monomeric, ideal solution. With increasing salt concentration this trend was eventually reversed. The hydrodynamic interactions of lysozyme in solution, extracted from the combination of static and dynamic scattering data, decreased significantly with increasing salt concentration. These observations reflect changes in protein interactions, in response to increased salt screening, from net repulsion to net attraction. Both salts had the same qualitative effect, but the quantitative behavior did not scale with the ionic strength of the solution. This indicates the presence of salt specific effects. At low protein concentrations, the slopes of K(sub c)(sub p)/R(sub theta) and D(sub c) vs c(sub p) were obtained. The dependence of the slopes on ionic strength was modeled using a DLVO potential for colloidal interactions of two spheres, with the net protein charge Z(sub e) and Hamaker constant A(sub H) as fitting parameters. The model reproduces the observed variations with ionic strength quite well. Independent fits to the static and dynamic data, however, led to different values of the fitting parameters. These and other shortcomings suggest that colloidal interaction models alone are insufficient to explain protein interactions in solutions.

Muschol, Martin↗

Quantitative molecular characterization of bovine vitreous and lens with non-invasive dynamic light scattering

The non-invasive technique of dynamic light scattering (DLS) was used to quantitatively characterize vitreous and lens structure on a molecular level by measuring the sizes of the predominant particles and mapping the three-dimensional topographic distribution of these structural macromolecules in three spatial dimensions. The results of DLS measurements in five fresh adult bovine eyes were compared to DLS measurements in model solutions of hyaluronan (HA) and collagen (Coll). In the bovine eyes DLS measurements were obtained from excised samples of gel and liquid vitreous and compared to the model solutions. Measurements in whole vitreous were obtained at multiple points posterior to the lens to generate a three-dimensional 'map' of molecular structure. The macromolecule distribution in bovine lens was similarly characterized.In each bovine vitreous (Bo Vit) specimen, DLS predominantly detected two distinct particles, which differed in diffusion properties and hence size. Comparisons with model vitreous solutions demonstrated that these most likely corresponded to the Coll and HA components of vitreous. Three-dimensional mapping of Bo Vit found heterogeneity throughout the vitreous body, with different particle size distributions for Coll and HA at different loci. In contrast, the three-dimensional distribution of lens macromolecules was more homogeneous. Thus, the non-invasive DLS technique can quantitate the average sizes of vitreous and lens macromolecules and map their three-dimensional distribution. This method to assess quantitatively the macromolecular structure of vitreous and lens should be useful for clinical as well as experimental applications in health and disease. Copyright 2001 Academic Press.

Models, Molecular↗

Unraveling the Effects of Cobalt on Crystal Growth and Solution Behavior of Nb 6 P 2 W 12 -based Dimeric Clusters

We report the synthesis, characterization, and solution self-assembly of plenary Nb 6 P 2 W 12 -based transition-metal substituted polyoxometalate, which is obtained by simply adding transition metals (Co 2+ ) into aqueous solution containing cluster [(NbO 2 ) 6 P 2 W 12 O 56 ] 12- , which is obtained by an in situ synthetic method. The incorporation of Co 2+ ions significantly affects the crystal structure, resulting in the formation of a 1D chain-like crystal and the first example of a niobotungstate-based cobalt derivative cluster. The behavior and stability of this cluster in solution are confirmed by time-resolved static light scattering, dynamic light scattering, small-angle X-ray scattering, and electrospray mass spectrometry studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating the quaternary structure of a homomultimeric catechol 1,2-dioxygenase: An integrative structural biology study

The structural analysis of catechol 1,2 dioxygenase from Stutzerimonas frequens GOM2, SfC12DO, was conducted using various structural techniques. SEC-SAXS experiments revealed that SfC12DO, after lyophilization and reconstitution processes, can form multiple enzymatically active oligomers, including dimers, tetramers, and octamers. These findings differ from previous studies, which reported active dimers in homologous counterparts with available crystallographic structures, or trimers observed exclusively in solution for SfC12DO and its homologous isoA C12DO from Acinetobacter radioresistens under low ionic strength conditions. In some cases, tetramers were also reported, such as for the Rodococcus erythropolis C12DO. The combined results of Small-Angle X-ray Scattering, Dynamic Light Scattering, and Transmission Electron Microscopy experiments provided additional insights into these active oligomers’ shape and molecular organization in an aqueous solution. These results highlight the oligomeric structural plasticity of SfC12DO, proving that it can exist in different oligomeric forms depending on the physicochemical characteristics of the solutions in which the experiments were performed. Remarkably, regardless of its oligomeric state, SfC12DO maintains its enzymatic activity even after prior lyophilization. All these characteristics make SfC12DO a putative candidate for bioremediation applications in polluted soils or waters.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic Light Scattering From Colloidal Gels

We present a brief, preliminary account of the interpretation of dynamic light scattering from fractal colloidal gels. For small scattering angles, and for high initial colloid particle volume fractions, the correlation functions exhibit arrested decay, reflecting the non-ergodic nature of these systems and allowing us to directly determine the elastic modulus of the gels. For smaller initial volume fractions, the correlation functions decay completely. In all cases, the initial decay is not exponential, but is instead described by a stretched exponential. We summarize the principles of a model that accounts for these data and discuss the scaling behavior of the measured parameters.

Krall, A. H.↗

Dynamic Light Scattering With Improved Fiber-Optic Probes

Improved fiber-optic probes developed for use in dynamic light-scattering measurements. Intended for measuring dynamic backscattering of laser light from concentrated suspensions of particles in liquids, for purpose of determining statistical distributions of sizes of particles. Offers advantages of compactness and ruggedness, and more suitable for industrial environments. Probes immersed in suspensions characterized. Associated lasers, photodetectors, and signal-processing circuits located remotely in safer environments, coupled to probes via optical fibers.

Dhadwal, Harbans Singh↗

Method and apparatus for determining the physical properties of materials using dynamic light scattering techniques

A system for determining the physical properties of materials through the use of dynamic light scattering is disclosed. The system includes a probe, a laser source for directing a laser beam into the probe, and a photodetector for converting scattered light detected by the probe into electrical signals. The probe includes at least one optical fiber connected to the laser source and a second optical fiber connected to the photodetector. Each of the fibers may adjoin a gradient index microlens which is capable of providing a collimated laser beam into a scattering medium. The position of the second optical fiber with respect to the optical axis of the probe determines whether homodyne or self-beating detection is provided. Self-beating detection may be provided without a gradient index microlens. This allows a very small probe to be constructed which is insertable through a hypodermic needle or the like into a droplet extending from such a needle. A method of detecting scattered light through the use of a collimated, Gaussian laser beam is also provided. A method for controlling the waist and divergence of the optical field emanating from the free end of an optical fiber is also provided.

Dhadwal, Harbans S.↗

Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice

The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Review↗

A New Clinical Instrument for The Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered fight and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

Ansari, Rafat R.↗