Search NASASearch

SEARCH · Search NASA

Results for “Dyson mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Equilibrium spin polarization arising from chirality

Chirality-induced spin selectivity (CISS) describes how chiral molecules and materials generate spin polarization even at thermal equilibrium. This observation has challenged established principles of microscopic reversibility and Onsager reciprocity. We resolve this paradox by formulating a pseudo-Hermitian quantum framework that separates thermodynamic equilibrium from time-reversal symmetry. Within this approach, structural chirality and electron correlations, irrespective of their microscopic origin, are sufficient to produce CISS observables. Chirality enters through a non-local metric η that couples spin and spatial motion, leading to real spectra, unitary evolution, and thermodynamic consistency. The framework predicts a chirality-induced spin magnetic ordering characterized by a spin-displacement order, which reconciles equilibrium spin polarization with detailed balance and explains the persistence of CISS in materials composed of light elements. We derive generalized Onsager-Casimir relations that respect the observed CISS symmetry, i.e., parity $(\mathscr{P})$-odd and time-reversal $(\mathscr{T})$-odd, but exhibiting $\mathscr{PT}$-even symmetry. This approach establishes a coherent foundation for equilibrium CISS and provides a route to link chemical chirality with measurable spin-to-charge conversion effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Europa Environmental Testing of Thermal Hardware for the Mapping Imaging Spectrometer for Europa (MISE) Instrument

The Europa Clipper spacecraft, scheduled for launch in June 2022, hosts a suite of instruments including the Mapping Imaging Spectrometer for Europa (MISE). MISE is a high-optical through-put pushbroom infrared imaging spectrometer that can collect measurements within Europa’s challenging radiation environment. It is externally mounted to the spacecraft and as a result is exposed to high radiation levels and cold temperatures. The instrument consists of a scan mirror assembly, an optical bench including a Dyson spectrometer and a telescope, and a structure that supports a cryocooler and a radiator. The cryocooler is used to actively cool the focal plane array and the spectrometer. The heat from the cryocooler is rejected through pyrolytic graphite sheet thermal straps to a honeycomb radiator. MISE will implement thermal hardware that will either not be used on other parts of the spacecraft or have a more extreme environment than the spacecraft. As a result, the MISE instrument performed numerous environmental tests on its thermal hardware. This paper discusses the results of the thermal cycling and radiation tests performed on the MISE thermal hardware including a Lockheed Martin Micro1-2 cryocooler, Pyrolytic graphite sheet thermal straps, Annealed pyrolytic graphite K-Core, Rosemount Platinum Resistance Thermometers, Tayco Kapton Thermofoil heaters, Dale Ohm resistors, and aluminum honeycomb and facesheets.

Strong, Patrick

Overview of Multi-Kilowatt Free-Piston Stirling Power Conversion Research at Glenn Research Center

As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors and a pair of commercially available pressure wave generators (which will be plumbed together to create a high power Stirling linear alternator test rig) have been procured for in-house testing at Glenn Research Center (GRC). Delivery of both the Stirling convertors and the linear alternator test rig is expected by October 2007. The 1 kW class free-piston Stirling convertors will be tested at GRC to map and verify performance. The convertors will later be modified to operate with a NaK liquid metal pumped loop for thermal energy input. The high power linear alternator test rig will be used to map and verify high power Stirling linear alternator performance and to develop power management and distribution (PMAD) methods and techniques. This paper provides an overview of the multi-kilowatt free-piston Stirling power conversion work being performed at GRC.

Geng, Steven M.

Overview of Multi-kilowatt Free-Piston Stirling Power Conversion Research at GRC

As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors and a pair of commercially available pressure wave generators (which will be plumbed together to create a high power Stirling linear alternator test rig) have been procured for in-house testing at Glenn Research Center. Delivery of both the Stirling convertors and the linear alternator test rig is expected by October, 2007. The 1 kW class free-piston Stirling convertors will be tested at GRC to map and verify performance. The convertors will later be modified to operate with a NaK liquid metal pumped loop for thermal energy input. The high power linear alternator test rig will be used to map and verify high power Stirling linear alternator performance and to develop power management and distribution (PMAD) methods and techniques. This paper provides an overview of the multi-kilowatt free-piston Stirling power conversion work being performed at GRC.

Geng, Steven M.

WISE-2005: Adrenergic Responses Before and After 60 Days of 6 Degree Head-Down Bed-Rest in Women

Sixteen women who participated in the WISE-2005 headdown bed rest (HDBR) were studied before and on day 56 of bed rest to test the hypothesis that chronic changes in circulating norepinephrine (NOR) would change the response to adrenergic receptor agonists. Five minute infusions of 2 doses of isoproterenol (ISO), and 2 doses of NOR were administered while heart rate (HR), mean arterial pressure (MAP) and total peripheral resistance (TPR) were measured. Before HDBR, the higher dose of ISO increased HR by 13 beats/min (P<O.OOl) and decreased TPR by -50% (P<O.OOl) with no changes in MAP, the higher dose of NOR increased MAP by 8 mmHg (P<O.OOl) and increased TPR -20% (P=0.007) with no change in HR. On HDBR day 56, subjects who took part in daily exercise+lower body negative pressure (EX+LBNP) countermeasures had no change in HR response to ISO while the control group (CON) had greater increases in HR. MAP tended to be lower post-HDBR in CON but not in EX+LBNP, while TPR was higher in both groups. In response to NOR, MAP increased with elevated TPR with no change in HR. Post-HDBR TPR increased more in the EX+LBNP group. These studies indicate that HDBR alters the HR response to IS0 but that EX+LBNP countermeasure prevented this change. The greater TPR response to NOR in the post-HDBR for the EX+LBNP group might reflect enhanced peripheral vasoconstrictor response that could reduce the risk of orthostatic intolerance after this countermeasure.

Edgell, H.

Long-Lived Venus Lander Conceptual Design: How To Keep It Cool

Surprisingly little is known about Venus, our neighboring sister planet in the solar system, due to the challenges of operating in its extremely hot, corrosive, and dense environment. For example, after over two dozen missions to the planet, the longest-lived lander was the Soviet Venera 13, and it only survived two hours on the surface. Several conceptual Venus mission studies have been formulated in the past two decades proposing lander architectures that potentially extend lander lifetime. Most recently, the Venus Science and Technology Definition Team (STDT) was commissioned by NASA to study a Venus Flagship Mission potentially launching in the 2020- 2025 time-frame; the reference lander of this study is designed to survive for only a few hours more than Venera 13 launched back in 1981! Since Cytherean mission planners lack a viable approach to a long-lived surface architecture, specific scientific objectives outlined in the National Science Foundation Decadal Survey and Venus Exploration Advisory Group final report cannot be completed. These include: mapping the mineralogy and composition of the surface on a planetary scale determining the age of various rock samples on Venus, searching for evidence of changes in interior dynamics (seismometry) and its impact on climate and many other key observations that benefit with time scales of at least a full Venus day (Le. daylight/night cycle). This report reviews those studies and recommends a hybrid lander architecture that can survive for at least one Venus day (243 Earth days) by incorporating selective Stirling multi-stage active cooling and hybrid thermoacoustic power.

Dyson, Ridger W.

A Road Map for the Exploration of Neighboring Planetary Systems (ExNPS)

A brown dwarf star having only 20-50 times the mass of Jupiter is located below and to the left of the bright star GL 229 in this image from the Hubble Space Telescope. At the 19 light year distance to GL 229, the 7.7-arcsec separation between the star and the brown dwarf corresponds to roughly the separation between Pluto and the Sun in our Solar System. The goal of the program described in this report is to detect and characterize Earth-like planets around nearby stars where conditions suitable for life might be found. For a star like the Sun located 30 light years away, the appropriate star-planet separation would be almost 100 times closer than seen here for GL 229B.

Elachi, Charles

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing