A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗