Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC APPLIANCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang↗

Defining Power Efficient Residential Electric Appliances and Equipment

While the long-established concept of "energy efficiency" has successfully reduced energy consumption and bills in homes, it is no longer sufficient to address the modern challenges of electrical load growth, infrastructure upgrades and associated affordability challenges. We introduce the concept of “power efficiency” for household appliances and equipment, providing a framework to support affordable home modernization and grid management. Energy efficiency is the measure of energy used (kWh) to provide comfort/conveniences, power efficiency is the measure of power used (kW) to provide those same comforts/conveniences. Energy efficiency was needed because energy is a limited resource and expensive. Now power efficiency is needed because power delivery into a building is a limited resource and expensive. We propose a new set of metrics for defining and measuring power efficiency by investigating how current appliance nameplate ratings are established, and assessing the availability and use of existing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantitative analysis of cost savings and occupants’ preferences in grid-interactive smart home operation

Many utility companies in the United States have introduced time-of-use (TOU) rates for homeowners with the goal of regulating electricity consumption during peak hours. The electrical appliances in homes include various thermostatically controlled devices, such as air conditioners (AC) for thermal comfort, and nonthermostatically controlled devices such as clothes washers. As a result, homeowners face the complicated challenge of economically operating multiple electrical appliances in their homes while maintaining comfort and convenience. This is usually due to the lack of an explicit understanding of the correlation between cost saving and the users’ comfort. To understand the correlation, this article is designed to construct a framework by integrating three major components: a multi-objective optimization method accommodating multiple competing goals with different weights, a learning-based system modeling approach describing the dynamics and thermal coupling effects of appliances, and a novel comfort index method differentiating preferred and acceptable thermal comfort. Our proposed framework can allow the indoor air temperature to fall into the "preferred" range with a marginal cost increase. Furthermore, the simulation result shows that an additional 8 h for the preferred thermal comfort can be achieved with a cost increase of only 1.77%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Depollution benchmarks for capacitors, batteries and printed wiring boards from waste electrical and electronic equipment (WEEE)

Highlights: • We’ve analysed data on the dismantling of electronic and electrical appliances. • Ten years of mass balance data of more than recycling companies have been considered. • Percentages of dismantled batteries, capacitors and PWB have been studied. • Threshold values and benchmarks for batteries and capacitors have been identified. • No benchmark for the dismantling of printed wiring boards should be set. - Abstract: The article compiles and analyses sample data for toxic components removed from waste electronic and electrical equipment (WEEE) from more than 30 recycling companies in Switzerland over the past ten years. According to European and Swiss legislation, toxic components like batteries, capacitors and printed wiring boards have to be removed from WEEE. The control bodies of the Swiss take back schemes have been monitoring the activities of WEEE recyclers in Switzerland for about 15 years. All recyclers have to provide annual mass balance data for every year of operation. From this data, percentage shares of removed batteries and capacitors are calculated in relation to the amount of each respective WEEE category treated. A rationale is developed, why such an indicator should not be calculated for printed wiring boards. The distributions of these de-pollution indicators are analysed and their suitability for defining lower threshold values and benchmarks for the depollution of WEEE is discussed. Recommendations for benchmarks and threshold values for the removal of capacitors and batteries are given.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of appliance ownership and electricity consumption determinants in urban Ghanaian households

The residential sector in Ghana accounts for about 40% of aggregate electricity consumption out of which urban centers contribute 70%. The high weighted share of residential electricity use is attributed to high appliance ownership and use, and other household/building factors. The ability to determine how changes in the pattern of these factors influence electricity demand is critical if efforts to reduce consumption are to be effective. Here this study combines a residential electricity consumption survey (RECS) with electricity end-use monitoring of 60 households in Tema city Ghana, to yield the first ever comprehensive investigation of city-scale electricity consumption in urban Ghanaian homes. A multiple linear regression analysis is used to identify the most statistically significant indicators of appliance ownership and household electricity consumption. Results indicate that ownership of air conditioner, freezer, fan, refrigerator and television; and changes in socio-economic and building factors such as energy efficiency awareness and practice; income; household size and floor space show high statistical significance, and collectively explain 57% variance in households’ total electricity consumption. The presence of dependent children increases ownership of television, iron, washing machine and small kitchen appliances. This work provides a solid foundation for developing more tailored energy-saving policy interventions targeted at households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Gas-Electric Energy System Decarbonization Planning

As energy utilities implement climate change mitigation policies, system planners require strategies for achieving affordable emissions reductions. Coordinated planning of electric power and natural gas systems will allow synergistic investments to address cross-sector operational constraints, competing uses for net-zero emissions fuels, and shifts in energy demands across energy carriers. In this study, we develop a novel optimization program that finds the cost-minimizing mix of infrastructure expansion or reduction across gas and electric systems to satisfy sector-specific emissions constraints. Alongside energy supply resources, our framework allows for central-planning of end-use equipment stocks to allow switching between gas and electric appliances upon failure or premature replacement. The proposed model is used to simulate case study scenarios for a benchmark 24-pipe gas network coupled to a 24-node power system test network. We find that electrification of greater than 80% of core gas demands is a component of the least-cost solution for modeled energy systems. Despite this substitution, the gas system is maintained to service difficult-to-electrify customers and to deliver net-zero emissions gas to electricity generators in times of peak electricity demand. Restricting electrification of gas appliances increases reliance on power- to-gas technologies and increases annual costs by 15% in 2040. Neglecting constraints on pipeline blending of hydrogen can produce a misleading result that relies on hydrogen blend fractions of greater than 50%. In all cases, we find the average costs of delivered gas increase nearly 5-fold across the decarbonization transition, highlighting the importance of future work investigating cost-allocation strategies for ensuring an equitable energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Effect of Cr{sup 3+} Ions Substitution on Structural and Magnetic Properties of Co Ferrite Nanoparticles

A series of polycrystalline nanoferrite having the chemical formula CoCr{sub x}Fe{sub 2−x}O{sub 4} (x = 0.0, 0.2, 0.4, 0.6, 0.8, and 1.0) were synthesized by sol-gel autocombustion method. X-ray diffraction (XRD) analysis was used to investigate the structural parameters and also to check the phase purity of all prepared samples. The analysis of XRD patterns revealed the formation of single-phase cubic spinel structure for all samples. The average particle size of the synthesized ferrites was identified by X-ray diffraction and scanning electron microscopy technique. The magnetic properties of Co-Cr nanoferrites were measured using a hysteresis loop tracer at room temperature and magnetic field of 5 KOe. Saturation magnetization (M{sub s}) and coercivity (H{sub c}) decrease with the increasing Cr{sup 3+} ions concentration in the Co-Cr ferrite, indicating that lesser magnetic Cr{sup 3+} ions substitute Fe{sup 3+} ions in the octahedral sublattice of the ferrite. Such materials are useful to reduce the energy loss in AC electrical appliances.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Concentrations of organophosphate flame retardants and plasticizers in urine from young children in Queensland, Australia and associations with environmental and behavioural factors

Highlights: • Eight OPFRs and eleven metabolites were measured in the urine of Australian kids. • Age was positively associated with BBOEP and negatively associated with BCIPP. • Mouthing activities were associated with higher concentrations of TBOEP, and TPHP. • Children living with window AC units had higher concentrations of BCIPHIPP and DBP. In recent years, the production and usage volumes of organophosphate flame retardants (OPFRs) has increased substantially. Certain OPFRs are suspected reproductive toxins, carcinogenic, and neurotoxic. Insufficient information is available on human exposure pathways to these chemicals, particularly in Australia. We aim to assess the association between OPFR concentrations in the urine of children to environmental and behavioural risk factors. Concentrations of eight OPFRs and eleven metabolites were measured in the urine of 51 children, aged 3–29 months, in Southeast Queensland, Australia and compared to their behavioural and environmental risk factor data obtained by an online questionnaire. Of the 11 OPFR metabolites analysed, 55% were frequently detected in the majority (> 80%) of samples. The most frequently detected metabolite was bis(1,3-dichloroisopropyl) phosphate (BDCIPP) (detected in 100% of samples), followed by 1-hydroxy-2-propyl bis(1-chloro-2-propyl) phosphate (BCIPHIPP) (96%), diphenyl phosphate (DPHP) (94%) and bis(1-chloroisopropyl) phosphate (BCIPP) (86%). In multivariable modelling, age was positively associated with concentrations of bis(2-butoxyethyl) phosphate (BBOEP) and negatively associated with concentrations of BCIPP and BCIPHIPP. Other non-age related factors, including vacuuming frequency, hand-washing frequency and presence and number of some electrical appliances in the home were also associated with concentrations of OPFR metabolites.

54 ENVIRONMENTAL SCIENCES↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EFFORT (EFFectiveness Of Rate sTructure for enabling demand response)

This tool helps utilities evaluate potential time of use price-plans and find effective hours for price plan on peak periods and the potential price-elastic demand response. An optimization model can be used to find tiered prices for the time of use tariffs and analyze the impact on load profiles, energy consumption, utility, and customer savings. The tool is equipped with an optimization model to determine the energy consumption of electric appliances that can leverage survey data containing information on the number of appliances owned by customers. Lastly, a statistical model can be used to predict system-level load based on exogenous parameters such as weather, time of day, month, type of day, and year. The tool is scripted in Python and uses the Pyomo python optimization language.

Duwadi, Kapil↗

Integrated Transmission and Distribution Control

Distributed, generation, demand response, distributed storage, smart appliances, electric vehicles and renewable energy resources are expected to play a key part in the transformation of the American power system. Control, coordination and compensation of these smart grid assets are inherently interlinked. Advanced control strategies to warrant large-scale penetration of distributed smart grid assets do not currently exist. While many of the smart grid technologies proposed involve assets being deployed at the distribution level, most of the significant benefits accrue at the transmission level. The development of advanced smart grid simulation tools, such as GridLAB-D, has led to a dramatic improvement in the models of smart grid assets available for design and evaluation of smart grid technology. However, one of the main challenges to quantifying the benefits of smart grid assets at the transmission level is the lack of tools and framework for integrating transmission and distribution technologies into a single simulation environment. Furthermore, given the size and complexity of the distribution system, it is crucial to be able to represent the behavior of distributed smart grid assets using reduced-order controllable models and to analyze their impacts on the bulk power system in terms of stability and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗