Apollo experience report: Electrical wiring subsystem

The general requirements of the electrical wiring subsystems and the problem areas and solutions that occurred during the major part of the Apollo Program are detailed in this report. The concepts and definitions of specific requirements for electrical wiring; wire-connecting devices; and wire-harness fabrication, checkout, and installation techniques are discussed. The design and development of electrical wiring and wire-connecting devices are described. Mission performance is discussed, and conclusions and recommendations for future programs are presented.

White, L. D.↗

Deep Koopman Neural Network for Analyzing High-Energy-Density Simulations of Electrical Wire Explosions

Megaampere-scale electrical wire experiments (EWEs) provide a platform for studying magnetohydrodynamic (MHD) instability growth in magneto-inertial fusion (MIF) devices. Even when nonlinear simulations of these experiments can digitally reproduce much of the experimentally observed instability growth, interpreting the results and understanding mode growth and evolution can be non-trivial. As a first step toward providing better interpretation of these simulation features, this work investigates the use of a deep neural network that uses Koopman operator theory to analyze the dynamics of pulsed-power-driven explosions of EWEs. This deep neural network is trained on 1-D resistive MHD simulations of EWEs. This neural network learns to transform the nonlinear data into a lower-dimensional representation where the time dynamics are linear. Layers of this neural network are shown to learn features of the simulations, including the locations of shock waves and different physical regimes of the simulation. Using the learned features, the network can compress a time state of the simulation consisting of 5120 data point into a 36-parameter lower-dimensional latent space embedding. Furthermore, these embeddings are shown to be clustered in the latent space by initial radius and time state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Materials for the Repair of Polyimide Electrical Wire Insulation

Two viable polyimide backbone materials have been identified that will allow the repair of polyimide electrical wire insulation found on the Space Shuttle and other aging aircraft. This identification is the outcome of ongoing efforts to assess the viability of using such polyimides and polyimide precursors (polyamic acids [PAAs]) as repair materials for aging polyimide electrical wire insulation. These repair materials were selected because they match the chemical makeup of the underlying wire insulation as closely as possible. This similarity allows for maximum compatibility, coupled with the outstanding physical properties of polyimides. The two polyimide backbone materials allow the polymer to be extremely flexible and to melt at low temperatures. A polymer chain end capping group that allows the polymer to crosslink into a nonflowable repair upon curing at around 200 C was also identified.

Source record↗

Integrated Electrical Wire Insulation Repair System

An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

Williams, Martha↗

Methods for Anticipating Problems with Electrical Wiring

Passive and active methods for anticipating problems with electrical wiring are provided. An insulative material in contact with an electrical conductor has at least one impurity that is impregnated in the insulative material and/or disposed thereon. An environment around the electrical conductor is monitored for the presence or the level of the impurity(ies) emanating from the insulative material in the form of a gaseous effluent. An alarm signal is generated when a predetermined level of the gaseous effluent is detected.

William T Yost↗

Marking Electrical Wiring With Condition Indicators

A method is provided for marking electrical Wiring with condition indicators. One or more markers are added to one or both of the insulative material and a surface of an electrical conductor such that it bonds thereto. Each marker is capable of emanating into a surrounding atmospheric environment as a gaseous effluent in response to a specific condition experienced by the electrical conductor.

Yost, William T.↗

Rating of electrical wires in vacuum environments

Electric conductors used in vacuum environments have smaller cross sections. This report provides data on the correct size wire for a required current load in free-air, low-pressure oxygen, and vacuum environments.

Schaefer, J. L.↗

Reaction and Protection of Electrical Wire Insulators in Atomic-oxygen Environments

Atomic-oxygen erosion on spacecraft in low Earth orbit is an issue which is becoming increasingly important because of the growing number of spacecraft that will fly in the orbits which have high concentrations of atomic oxygen. In this investigation, the atomic-oxygen durability of three types of electrical wire insulation (carbon-based, fluoropolymer, and polysiloxane elastomer) were evaluated. These insulation materials were exposed to thermal-energy atomic oxygen, which was obtained by RF excitation of air at a pressure of 11-20 Pa. The effects of atomic-oxygen exposure on insulation materials indicate that all carbon-based materials erode at about the same rate as polyamide Kapton and, therefore, are not atomic-oxygen durable. However, the durability of fluoropolymers needs to be evaluated on a case by case basis because the erosion rates of fluoropolymers vary widely. For example, experimental data suggest the formation of atomic fluorine during atomic-oxygen amorphous-fluorocarbon reactions. Dimethyl polysiloxanes (silicone) do not lose mass during atomic-oxygen exposure, but develop silica surfaces which are under tension and frequently crack as a result of loss of methyl groups. However, if the silicone sample surfaces were properly pretreated to provide a certain roughness, atomic oxygen exposure resulted in a sturdy, non-cracked atomic-oxygen durable SiO2 layer. Since the surface does not crack during such silicone-atomic oxygen reaction, the crack-induced contamination by silicone can be reduced or completely stopped. Therefore, with proper pretreatment, silicone can be either a wire insulation material or a coating on wire insulation materials to provide atomic-oxygen durability.

Hung, Ching-Cheh↗

Means for accommodating large overstrain in lead wires

An electrical wire is reported along whose length loops are formed at intervals and retained in a plastic capsule that allows unfolding of the loop when tension is exerted on the opposite ends of the wire. The capsule is formed by encompassing each loop with a sleeve of heat shrinkable synthetic plastic material which overlaps the loop and heat shrinking the overlapping portions. Thus, a length of electrical wire is formed which stores extra lengths of wire in the quantity needed to match the expected stretching of materials or elements such as ropes, cords and the like of high elongation to which the electrical wire may be attached.

Rumble, C. V.↗

Single-Step Shear-Based Deformation Processing of Electrical Conductor Wires

Commercial electrical conductor wires are currently produced from aluminum alloys by multi-step deformation processing involving rolling and drawing. These processes typically require 10 to 20 steps of deformation, since the plastic strain or reduction that can be imposed in a single step is limited by material workability and process mechanics. Here, we demonstrate a fundamentally different, single-step approach to produce flat wire aluminum products using machining-based deformation that also ensures adequate material workability in the formed product. Two process routes are proposed: (1) chip formation by free-machining (FM), with a post-machining, light drawing reduction (<20%) to achieve desired finish and (2) constrained chip formation by large strain extrusion machining (LSEM). Using commercially pure aluminum conductor alloys (Al 1100 and EC1350) as representative material systems, we demonstrate key features of the machining-based processing, including (a) single-step processing to achieve flat wire geometries, (b) surface finish (Ra = 0.2 to 1.0 μm) comparable to that of commercial wire products made by drawing/rolling, (c) deformation control independent of wire size, and (d) hardness increases of 50–150% over that of annealed wires, while retaining high electrical conductivity (>56% IACS). Here, the wire microstructure, which can also be varied via the large-strain deformation parameters, is correlated with mechanical and electrical properties. Implications for commercial manufacture of flat wire products are discussed.