High-Frequency Metal-Oxide Varistor Modeling Response to Early-time Electromagnetic Pulses.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The effects of a low-power electromagnetic pulse on the grain size and cooling curve of high-strength aluminum alloy 7A04 were investigated for various pulse duty cycles. This electromagnetic pulse treatment was found to effectively produce fine grains with globular crystals and a uniform microstructure for pulse duty cycles between 20 and 40%. The key factors that affected grain refinement under the electromagnetic pulse included the electromagnetic energy and the conversion frequency between B and E. The nucleation rate increased as the nucleation period was extended. A new kinetic condition of magnetic nucleation was explored by decreasing the critical Gibbs free energy in the electromagnetic pulse, which was more sensitive under low undercooling. In addition, the crystal orientation was controlled in such a solidification environment.
Electromagnetic Pulse (EMP) poses a significant threat to the normal operation of power systems, especially with the increasing penetration of renewable energy. Without adequate protection, EMP can severely damage equipment or result in circuit breakdowns or short circuits. Solar photovoltaic (PV) facilities are particularly susceptible to EMP since PV systems are outdoors and exposed to EMP radiation. To assess and mitigate this threat, this paper summarizes various models and tests used to study the effects of EMP on PV systems, assesses the nature of the threat, and identifies measures to mitigate it. The paper provides a comprehensive review by categorizing analytical methods based on their pros and cons, introducing and describing EMP-related events, and providing a taxonomy of analytical methods for studying EMP. This paper compares the processes of modeling, testing, and mitigating EMP at both the component and system levels of PV systems. Furthermore, it also presents a case study that reveals the vulnerability of solar inverters to EMP using the pulse current injection method. Finally, the paper discusses some of the remaining challenges that should be considered in future solar PV system design and deployment.
The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.
A new method is suggested for generating quasi-unipolar electromagnetic IR and terahertz pulses. The method is based on synchronous acceleration of electrons combined to a dense bunch with a charge of up to several tens nanocoulombs, which are forced out from a nanoscale target under an action of a high-power, sharp-leading edge laser pulse. The electromagnetic bunch moving in a field of laser radiation can generate high-power electromagnetic pulses with various spectral composition including terahertz and IR ranges. A physical mechanism underlying the formation of generated quasi-unipolar pulses of electromagnetic radiation is determined and numerically studied. The pulse characteristics are found by numerical simulation, such as amplitude and duration dependences on the angle between the pulse propagation direction and laser beam axis. It is established that in modern laser installations, the amplitudes of quasi-unipolar pulses may reach relativistic values. Reflection of a unipolar pulse from an ideally reflecting surface is numerically analysed. It is shown that the pulse retains its unipolar profile in this case. (paper)
Based on the analytical solution of the Schrödinger equation, we have considered the reemission of attosecond and shorter electromagnetic pulses by multielectron atoms in the sudden perturbation approximation. We have developed a technique of calculating the spectra for the reemission of attosecond and shorter electromagnetic pulses by neutral multielectron atoms with nuclear charges from 1 to 92. The results are presented in the form of analytical formulas dependent on several coefficients and screening parameters tabulated for all of the atoms whose electron densities are described by the well-known Dirac–Hartree–Fock–Slater model. As examples we have calculated the spectra for the reemission by lithium, carbon, calcium, and iron atoms for two types of incident pulse: Gaussian and “sombrero.”.
In inertial confinement fusion, electromagnetic pulses (EMPs) can be produced during high-power laser interacting with solid targets, which are intimately related to laser intensity and laser energy. In this study, EMPs generated by hybrid laser pulses coupling with targets are recorded and analyzed. The results indicate that a single picosecond laser gives birth to the most intense EMPs, but they are remarkably suppressed when a nanosecond laser-shooting target is triggered before the picosecond and femtosecond laser. One possible hypothesis is proposed based on x-rays inducing pre-ablation that generates pre-plasma at the surfaces of the picosecond target and femtosecond target, leading to a sharp drop both in the energy and number of the emitting hot electrons and protons. Here, the findings will deepen our understanding of the mechanism of EMPs' generation and will also open a new avenue to regulate EMPs by hybrid laser pulses.
Nonstationary perturbation theory is used to study generation of quantum vortices resulting from ionization of hydrogen-like atom by an ultrashort pulse of classical electromagnetic field. It is shown that the vortices are determined by quantum interference effects.
The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.
The problem of collisionless absorption of ultrawideband electromagnetic pulses in the ionosphere is studied analytically. It is shown that absorption has a resonance character if the repetition rate of a train of pulses is equal to the frequency of the excited plasma waves.
A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.
The study focuses on source region electromagnetic pulse (EMP), and provides considerations regarding the impact from an EMP due to a low-altitude nuclear denotation.
Laser–target interactions generate intense electromagnetic pulses (EMPs) that can interfere with measurements and damage equipment. In this paper we show that applying a magnetic field to nanosecond pulse laser–target interactions decreases the magnitude of EMPs. We demonstrate this effect in two experiments with different geometries (spherical versus planar), laser intensities ( ∼10 13 versus ∼10 15 W/cm 2 ) and applied field strength (12 versus 0.1 T) that both observed suppression of EMPs in approximately the 1 GHz band (by factors of 0.65× and 0.32×, respectively). We then observe the opposite effect at high intensities with a picosecond pulse: for planar experiments with laser intensities of approximately 10 19 W/cm 2 and magnetic fields of 6–10 T, the magnitude of EMPs is increased by a factor of 1.75×. These results provide a benchmark for models of EMP generation, but suggest that magnetic fields are not a viable solution for mitigating EMPs in the high-intensity laser facilities where they are most damaging.
Sandia National Laboratories sponsored a three-year internally funded Laboratory Directed Research and Development (LDRD) effort to investigate the vulnerabilities and mitigations of a high-altitude electromagnetic pulse (HEMP) on the electric power grid. The research was focused on understanding the vulnerabilities and potential mitigations for components and systems at the high voltage transmission level. Results from the research included a broad array of subtopics, covered in twenty-three reports and papers, and which are highlighted in this executive summary report. These subtopics include high altitude electromagnetic pulse (HEMP) characterization, HEMP coupling analysis, system-wide effects, and mitigating technologies.
This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.
Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.
A systematic approach is presented to evaluate the effects of high-altitude electromagnetic pulse (HEMP) signals on the equipment located inside a power generation facility. The approach uses a combination of practical measurement and simulation efforts to characterize the radio wave propagation behavior and the device immunity profile. Of particular interest in this work was estimating the vulnerability level of equipment that is connected to long cables. As an example application, a detailed study was conducted for one common class of facility equipment, and its frequency- and time-domain HEMP coupling properties were investigated as a function of terminal loading condition and cable attachment configuration. Overall, the proposed method can be generalized and applied to other electronic components and systems found in the facility environment.
This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.