Search NASASearch

SEARCH · Search NASA

Results for “ELECTROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of The Performance of The Mars Environmental Compatibility Assessment Electrometer

The Mars Environmental Compatibility Assessment (MECA) electrometer is an instrument that was designed jointly by researchers at the Jet Propulsion Laboratory and the Kennedy Space Center, and is intended to fly on a future space exploration mission of the surface of Mars. The electrometer was designed primarily to study (1) the electrostatic interaction between the Martian soil and five different types of insulators, which are attached to the electrometer, as the electrometer is rubbed over the Martian soil. The MECA/Electrometer is also capable of measuring (2) the presence of charged particles in the Martian atmosphere, (3) the local electric field strength, and (4) the local temperature. The goal of the research project described in this report was to test and evaluate the measurement capabilities of the MECA/Electrometer under simulated Martian surface conditions using facilities located in the Labs and Testbeds Division at the Kennedy Space Center. The results of this study indicate that the Martian soil simulant can triboelectrically charge up the insulator surface. However, the maximum charge buildup did not exceed 18% of the electrometer's full-range sensitivity when rubbed vigorously, and is more likely to be as low as 1% of the maximum range when rubbed through soil. This indicates that the overall gain of the MECA/Electrometer could be increased by a factor of 50 if measurements at the 50% level of full-range sensitivity are desired. The ion gauge, which detects the presence of charged particles, was also evaluated over a pressure range from 10 to 400 Torr (13 to 533 mbar). The electric field sensor was also evaluated. Although the temperature sensor was not evaluated due to project time constraints, it was previously reported to work properly.

Mantovani, James G.

Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer

The Mars Environmental Compatibility Assessment (MECA) electrometer is an instrument that was designed jointly by researchers at the Jet Propulsion Laboratory and the Kennedy Space Center, and is intended to fly on a future space exploration mission of the surface of Mars. The electrometer was designed primarily to study (1) the electrostatic interaction between the Martian soil and five different types of insulators, which are attached to the electrometer, as the electrometer is rubbed over the Martian soil. The MECA/Electrometer is also capable of measuring (2) the presence of charged particles in the Martian atmosphere, (3) the local electric field strength, and (4) the local temperature. The goal of the research project described in this report was to test and evaluate the measurement capabilities of the MECA/Electrometer under simulated Martian surface conditions using facilities located in the Labs and Testbeds Division at the Kennedy Space Center. The results of this study indicate that the Martian soil simulant can triboelectrically charge up the insulator surface. However, the maximum charge buildup did not exceed 18% of the electrometer's full-range sensitivity when rubbed vigorously, and is more likely to be as low as 1% of the maximum range when rubbed through soil. This indicates that the overall gain of the MECA/Electrometer could be increased by a factor of 50 if measurements at the 50% level of full-range sensitivity are desired. The ion gauge, which detects the presence of charged particles, was also evaluated over a pressure range from 10 to 400 Torr (13 to 533 mbar). The electric field sensor was also evaluated. Although the temperature sensor was not evaluated due to project time constraints, it was previously reported to work properly.

Mantovani, James G.

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Initial Flight Results

The Electrostatic Regolith Interaction Experiment (ERIE) is a suborbital flight payload studying electrostatically charged dust particle dynamics under microgravity, jointly developed by University of Central Florida (UCF) and NASA Kennedy Space Center (KSC). ERIE combines components from two systems, the COLLisions Into Dust Experiment (COLLIDE) from UCF and the Wheel Electrostatic Spectrometer (WES) from NASA KSC, to advance understanding of charged grain behavior on low gravity bodies such as the Moon and asteroids. ERIE slides a door containing an electrometer system monitoring various insulating disks across the surface of a regolith simulant bed. The experiment is activated when the payload enters the microgravity potion of the flight. The grains in the simulant bed tribocharge via agitation during launch as well as through frictional interactions with the door and its protruding insulators. As the retention door retracts, particles are allowed to loft into an open volume, achieving motion due to electrostatic repulsion. The electrometer system measures the charge transfer between the granular material and the insulators. As the charged grains exit the bed, they travel through an applied electric field and a camera observes the kinematics of the individual grains whose trajectories are determined by their net charges. The design of the ERIE electrometer instrument and initial results from the first flight was presented at the 2021 AGU Fall Meeting under P55E-2002. Shortly after microgravity was achieved and the retaining door began to open, the rate of charge acquisition measured by the electrometer increased, indicating the insulators were accumulating triboelectric charge. Charged grains were observed in the video data to traverse across the external electric field and become deflected from a linear path due to their charges. Pairs of grains were also observed to orbit one another as expected from two oppositely charged bodies in proximity to one another. Improvements to the design of the instrument and preliminary results obtained from the second flight scheduled for Q3 2022 will be presented at this meeting.

Electrostatics

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Initial Flight Results

The Electrostatic Regolith Interaction Experiment (ERIE) is a suborbital flight payload studying electrostatically charged dust particle dynamics under microgravity, jointly developed by University of Central Florida (UCF) and NASA Kennedy Space Center (KSC). ERIE combines components from two systems, the COLLisions Into Dust Experiment (COLLIDE) from UCF and the Wheel Electrostatic Spectrometer (WES) from NASA KSC, to advance understanding of charged grain behavior on low gravity bodies such as the Moon and asteroids. ERIE slides a door containing an electrometer system monitoring various insulating disks across the surface of a regolith simulant bed. The experiment is activated when the payload enters the microgravity potion of the flight. The grains in the simulant bed tribocharge via agitation during launch as well as through frictional interactions with the door and its protruding insulators. As the retention door retracts, particles are allowed to loft into an open volume, achieving motion due to electrostatic repulsion. The electrometer system measures the charge transfer between the granular material and the insulators. As the charged grains exit the bed, they travel through an applied electric field and a camera observes the kinematics of the individual grains whose trajectories are determined by their net charges. The design of the ERIE electrometer instrument and initial results from the first flight was presented at the 2021 AGU Fall Meeting under P55E-2002. Shortly after microgravity was achieved and the retaining door began to open, the rate of charge acquisition measured by the electrometer increased, indicating the insulators were accumulating triboelectric charge. Charged grains were observed in the video data to traverse across the external electric field and become deflected from a linear path due to their charges. Pairs of grains were also observed to orbit one another as expected from two oppositely charged bodies in proximity to one another. Improvements to the design of the instrument and preliminary results obtained from the second flight scheduled for Q3 2022 will be presented at this meeting.

Electrostatics

Electrometer system measures nanoamps at high voltage

Floating electrometer eliminates major source of error since any leakage from electrometer case, which is at high voltage, appears only as load on high voltage supply and not as part of current being measured. Commands to and data from floating electrometer are transferred across high voltage interface by means of optical channels.

Sturman, J. C.

MECA Electrometer: An Old Instrument Finds a New Application

The Mars '01 binder contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith (soil) and atmosphere. The electrometer is part of MECA (Mars Environmental Compatibility Assessment) project. The objective is to gain a better understanding of the hazards related to the human exploration of Mars. The electrometer was designed to fit into the heel of the scoop of the robotic arm. The instrument has four sensor types: (a) triboelectric field, (b) electric-field, (c) ion current, and (d) temperature. The triboelectric field sensor array contains five insulating materials to determine material charging effects as the scoop is dragged through the Martian regolith. The sensor has an electric field sensitivity of 35 kV/cm-V and room temperature drift of approx.3 micro V/sec. The sensor has been operated as low as -60 C where the drift is undetected. This talk with focus on the operating principles of the triboelectric sensors and present some of test results.

Buehler, Martin

Electrometer has automatic zero bias control

Zero biasing circuit in a vibrating reed type electrometer counterbalances residual potential. It charges a capacitor to the residual potential and connects that capacitor in series with the vibrating reed so that the voltages cancel. This enables the electrometer to read zero output potential in the absence of an input current.

Source record

Three-terminal shielded resistors for fast electrometers

The design of electrometer feedback resistors for use at frequencies up to the kilohertz range is discussed. It is shown experimentally that the addition of capacitive coupling between the electrometer output and the center of the feedback resistor, combined with suitable shielding, gives substantially better performance at high frequencies than is obtainable with more conventional designs.

Kendall, B. R. F.

MECA Electrometer: Initial Experimental Results

The Mars '01 lander contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith (soil) and atmosphere. The electrometer is part of MECA (Mars Environmental Compatibility Assessment) project. The objective is to gain a better understanding of the hazards related to the human exploration of Mars The sensor has an electric field sensitivity of 35 kV/cm-V and room temperature drift of about 3 microV/sec. The sensor has been operated as low as -60 C where the drift is undetected.

Buehler, M.

MECA Electrometer: Initial Experimental Results

The Mars '01 lander contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith (soil) and atmosphere. The electrometer is part of MECA (Mars Environmental Compatibility Assessment) project. The objective is to gain a better understanding of the hazards related to the human exploration of Mars The sensor has an electric field sensitivity of 35 kV/cm V and room temperature drift of approx. 3 micro V/sec. The sensor has been operated as low as - 60 C where the drift is undetected. Additional information is contained in the original extended abstract.

Buehler, M.

Floating-diffusion electrometer with adjustable sensitivity

The effective capacitance of the floating diffusion in a floating-diffusion electrometer is modified to adjust electrometer sensitivity. This is done by changing the direct potential applied to a gate electrode proximate to the floating diffusion.

Tower, John R.

Wheel Electrometer System

Two documents describe a prototype system of electrometers for measuring electrostatic fields and electrostatic responses of soils on Mars and the Moon. The electrodes of this electrometer are embedded in a wheel of an exploratory robotic vehicle, utilizing the wheel motion to bring the electrodes into proximity or contact with the soil. Each electrode resides in one of two types of sensor modules: electric-field (ELF) or triboelectric (TRIBO). In either type, what is measured is simply the electric charge induced on the electrode by exposure to the external distribution of electrostatic charge. In an ELF module, the electrode is bare and recessed radially from the wheel surface. The ELF sensor provides a measure of the charge on a small patch of undisturbed soil as the wheel rolls forward. In a TRIBO module, the electrode is only slightly recessed and covered with a polymeric insulator flush with the wheel surface. Through contact electrification, the insulator exchanges charge with the soil. There are five TRIBO sensors, each containing an insulator made of a different polymer. The charge data gathered by the five TRIBO sensors can be used to determine how the soil fits into a triboelectric series.

Calle, Carlos I.

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.

Put FETs to Work in Electrometers

Field-effect transistors, with their high impedance and low noise, can effectively measure very low currents. To bring the FET up to electrometer standards (so that it can measure currents of, say, 10 (sup -13) amp) the designer must know where the noise is and what to do about it.

ELECTROMETER