Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMYOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Power spectral density analysis of the electromyogram from a work task performed in a full pressure suit

Surface electromyograms (EMG) taken from three upper torso muscles during a push-pull task were analyzed by a power spectral density technique to determine the utility of the spectral analysis for identifying changes in the EMG caused by muscular fatigue. The results confirmed the value of the frequency analysis for identifying fatigue producing muscular performance. Data revealed reliable differences between muscles in fatigue induced responses to various locations in the reach envelope at which the subjects were required to perform the push-pull exercise, and the differential sensitivity of individual muscles to the various reach positions; i.e., certain reach positions imposed more fatigue related shifts in EMG power than did others. It was found that a pressurized space suit changed the pattern of normal shirtsleeve muscle fatigue responses in all three of the muscles.

Lafevers, E. V.↗

A stochastic model of the electromyogram

The quantitative regularities of interference pattern formation by motor unit action potentials is investigated. The parameters of a single motor unit and how they relate to the Fourier transform analysis of an EMG are considered. The Fourier transform of the simulated electromyogram is compared with the Fourier transform of the actual EMG recorded from various human muscles using surface electrodes.

Agarwal, G. C.↗

Evaluation of localized muscle fatigue using power spectral density analysis of the electromyogram

Surface electromyograms (EMGs) taken from three upper torso muscles during a push-pull task were analyzed by a power spectral density technique to determine the operational feasibility of the technique for identifying changes in the EMGs resulting from muscular fatigue. The EMGs were taken from four subjects under two conditions (1) in shirtsleeves and (2) in a pressurized space suit. This study confirmed that frequency analysis of dynamic muscle activity is capable of providing reliable data for many industrial applications where fatigue may be of practical interest. The results showed significant effects of the pressurized space suit on the pattern of shirtsleeve fatigue responses of the muscles. The data also revealed (1) reliable differences between muscles in fatigue-induced responses to various locations in the reach envelope at which the subjects were required to perform the push-pull exercise and (2) the differential sensitivity of muscles to the various reach positions in terms of fatigue-related shifts in EMG power.

Lafevers, E. V.↗

Short time Fourier analysis of the electromyogram - Fast movements and constant contraction

Short-time Fourier analysis was applied to surface electromyograms (EMG) recorded during rapid movements, and during isometric contractions at constant forces. A portion of the data to be transformed by multiplying the signal by a Hamming window was selected, and then the discrete Fourier transform was computed. Shifting the window along the data record, a new spectrum was computed each 10 ms. The transformed data were displayed in spectograms or 'voiceprints'. This short-time technique made it possible to see time-dependencies in the EMG that are normally averaged in the Fourier analysis of these signals. Spectra of EMGs during isometric contractions at constant force vary in the short (10-20 ms) term. Short-time spectra from EMGs recorded during rapid movements were much less variable. The windowing technique picked out the typical 'three-burst pattern' in EMG's from both wrist and head movements. Spectra during the bursts were more consistent than those during isometric contractions. Furthermore, there was a consistent shift in spectral statistics in the course of the three bursts. Both the center frequency and the variance of the spectral energy distribution grew from the first burst to the second burst in the same muscle. The analogy between EMGs and speech signals is extended to argue for future applicability of short-time spectral analysis of EMG.

Hannaford, Blake↗

Physiological response to submaximal isometric contractions of the paravertebral muscles

STUDY DESIGN: Brief (30-second) isometric trunk extensions at 5%, 20%, 40%, 60%, and 80% of maximal voluntary contraction (MVC) and 3 minutes of prolonged trunk extension (20% MVC) in erect position were studied in nine healthy male subjects. OBJECTIVES: To investigate the intercorrelation between intramuscular pressure and tissue oxygenation of the paravertebral muscles during submaximal isometric contractions and further, to evaluate paravertebral electromyogram and intramuscular pressure as indicators of force development. SUMMARY OF BACKGROUND DATA: Local physiologic responses to muscle contraction are incompletely understood. METHODS: Relative oxygenation was monitored with noninvasive near-infrared spectroscopy, intramuscular pressure was measured with a transducer-tipped catheter, and surface electromyogram was monitored at three recording sites. RESULTS: The root mean square amplitudes of the paravertebral electromyogram (L4, left and right; T12, right) and intramuscular pressure measured in the lumbar multifidus muscle at L4 increased with greater force development in a curvilinear manner. A significant decrease in the oxygenation of the lumbar paravertebral muscle in response to muscle contraction was found at an initial contraction level of 20% MVC. This corresponded to a paravertebral intramuscular pressure of 30-40 mm Hg. However, during prolonged trunk extension, no further decrease in tissue oxygenation was found compared with the tissue oxygenation level at the end of the brief contractions, indicating that homeostatic adjustments (mean blood pressure and heart rate) over time were sufficient to maintain paravertebral muscle oxygen levels. CONCLUSION: At a threshold intramuscular pressure of 30-40 mm Hg during muscle contraction, oxygenation in the paravertebral muscles is significantly reduced. The effect of further increase in intramuscular pressure on tissue oxygenation over time may be compensated for by an increase in blood pressure and heart rate. Surface electromyogram amplitudes and intramuscular pressure can be used as indicators of paravertebral muscle force.

NASA Center ARC↗

Impact of resistance exercise during bed rest on skeletal muscle sarcopenia and myosin isoform distribution

Because resistance exercise (REx) and bed-rest unloading (BRU) are associated with opposing adaptations, our purpose was to test the efficacy of REx against the effects of 14 days of BRU on the knee-extensor muscle group. Sixteen healthy men were randomly assigned to no exercise (NoEx; n = 8) or REx (n = 8). REx performed five sets of leg press exercise with 80-85% of one repetition maximum (1 RM) every other day during BRU. Muscle samples were removed from the vastus lateralis muscle by percutaneous needle biopsy. Myofiber distribution was determined immunohistochemically with three monoclonal antibodies against myosin heavy chain (MHC) isoforms (I, IIa, IIx). MHC distribution was further assessed by quantitative gel electrophoresis. Dynamic 1-RM leg press and unilateral maximum voluntary isometric contraction (MVC) were determined. Maximal neural activation (root mean squared electromyogram) and rate of torque development (RTD) were measured during MVC. Reductions (P < 0.05) in type I (15%) and type II (17%) myofiber cross-sectional areas were found in NoEx but not in REx. Electrophoresis revealed no changes in MHC isoform distribution. The percentage of type IIx myofibers decreased (P < 0.05) in REx from 9 to 2% and did not change in NoEx. 1 RM was reduced (P < 0.05) by 9% in NoEx but was unchanged in REx. MVC fell by 15 and 13% in NoEx and REx, respectively. The agonist-to-antagonist root mean squared electromyogram ratio decreased (P < 0.05) 19% in REx. RTD slowed (P < 0.05) by 54% in NoEx only. Results indicate that REx prevented BRU-induced myofiber atrophy and also maintained training-specific strength. Unlike spaceflight, BRU did not induce shifts in myosin phenotype. The reported benefits of REx may prove useful in prescribing exercise for astronauts in microgravity.

NASA Discipline Musculoskeletal↗

Tiny biomedical amplifier combines high performance, low power drain

Transistorized, portable, high performance amplifier with low power drain facilitates biomedical studies on mobile subjects. This device, which utilizes a differential input to obtain a common-mode rejection, is used for amplifying electrocardiogram and electromyogram signals.

Deboo, G. J.↗

Implanted telemeter for electrocardiogram and body temperature

Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.

Barrows, W. F.↗

Development of techniques for measuring pilot workload

An objective method of assessing information workload based on physiological measurements was developed. Information workload, or reserve capacity, was measured using a visual discrimination secondary task and subjective rating of task difficulty. The primary task was two axis (pitch and roll) tracking, and the independent variables in this study were aircraft pitch dynamics and wind gust disturbances. The study was structured to provide: (1) a sensitive, nonloading measure of reserve capacity, and (2) an unencumbering reliable measurement of the psychophysiological state. From these, a measured workload index (MWI) and physiological workload index (PWI) were extracted. An important measure of the success of this study was the degree to which the MWI and PWI agreed across the 243 randomly-presented, four-minute trials (9 subjects X 9 tasks X 3 replications). The electrophysiological data collected included vectorcardiogaram, respiration, electromyogram, skin impedance, and electroencephalogram. Special computer programs were created for the analysis of each physiological variable. The digital data base then consisted of 82 physiological features for each of the 243 trials. A prediction of workload based on physiological observations was formulated as a simultaneous least-squares prediction problem. A best subset of 10 features was chosen to predict the three measures of reserve capacity. The cannonical correlation coefficient was .754 with a chi squared value of 91.3 which allows rejection of the null hypothesis with p of .995.

Spyker, D. A.↗

Miniature biotelemeter giving 10 channels of wideband biomedical data.

A miniature biotelemeter has been developed for sensing and transmitting multiple channels of wideband biomedical data over a radio link. Its small size and weight make it capable of being carried by free-moving laboratory animals as small as rats. Ten data channels each of 5-kHz data bandwidth are provided to permit monitoring of a wide variety of physiological signals. Multichannel telemetry of electroencephalograms, electrocardiograms, electromyograms, state functions, and dynamic processes such as blood flow and body chemistry are possible applications. Utilization of newly available monolithic chip components, low-power COS/MOS MSI digital logic, and state-of-the-art hybrid mounting techniques makes this novel device useful for both research and clinical bioinstrumentation.

Carraway, J.↗

Effects of low frequency vibration of a limb

Low frequency oscillations were applied on the ankle joint in plantarflexion/dorsiflexion rotation using a torque motor. The torque, the angular rotation and the evoked electromyogram from the gastronemius soleus and the anterior tibial muscles were recorded. Significant nonlinearities were observed in the angular rotation from 8 to 12 Hz. The following methods are used for data analysis: (1) Two cycle averaged response; (2) Fourier transform; and (3) Fourier analysis at the driving frequency. Important observations are: (1) resonance near 6 to 8 Hz; (2) slowly increasing amplitudes of oscillation near resonance; (3) self sustaining oscillations after the motor is turned off, particularly in the fatigued limb; and (4) distortion of angular rotation during which there are spontaneous recurrences of oscillation at the driving frequency.

Agarwal, G. C.↗

Spectral analysis of skeletal muscle changes resulting from 59 days of weightlessness in Skylab 2

During stressful exercise of the m. gastrocnemius, preflight and postflight surface electromyograms (EMG) were taken from each of the Skylab II astronauts. Measurements on the muscle were made once 5 days before launch, and four times postflight on recovery day, 4 days after recovery, 16 days after recovery and 29 days after recovery. It was hypothesized that the disused gastrocnemius would exhibit dysfunction characteristics similar to those found in laboratory studies on disuse and of pathologically astrophied muscle, and that physical stress would be associated with heightened fatigability in the muscle. Both hypotheses were sustained. The results showed significant shifts of the predominant frequency of the gastrocnemius into higher than normal bands which suggests a relationship between muscle disuse characteristics and pathologic dysfunction characteristics. It was concluded that the spectrally analyzed EMG is a sensitive measure of muscle dsyfunction that is associated with disuse. Antigravity muscles exhibit heightened susceptibility to fatigue when subjected to lengthy weightlessness.

Lafevers, E. V.↗

Report of 14-day bedrest simulation of Skylab

Part one of a two-phase bedrest project in which the physiological effects of weightlessness were simulated is presented. The project was designed to approximate the medical testing and dietary control of Skylab. The test period included a three week pre-flight period, a two week bedrest period and a two week post-flight period. The test subjects ate measured amounts of the Skylab diet and drank deionized water to recreate the metabolic balance studies of Skylab. The medical testing program, pre- and postbedrest, was similar to that of Skylab including: lower body negative pressure testing the orthostatic intolerance noted after both spaceflights and bedrest, bicycle ergometry testing the cardiovascular response to graded exercise, postural equilibrium, vestibular studies and electromyograms. Fluid and electrolyte shifts and balance were documented with intake and output records and radionuclide studies. The subjects were observed by a psychiatrist who watched for signs of mental stress in the test environment and changes in mental status.

Johnson, P. C.↗

Electromyographic analysis of skeletal muscle changes arising from 9 days of weightlessness in the Apollo-Soyuz space mission

Both integration and frequency analyses of the electromyograms from voluntary contractions were performed in one crewman of the Apollo-Soyuz Test Project mission. Of particular interest were changes in excitability, electrical efficiency, and fatigability. As a result of 9 days of weightlessness, muscle excitability was shown to increase; muscle electrical efficiency was found to decrease in calf muscles and to increase in arm muscles; and fatigability was found to increase significantly, as shown by spectral power shifts into lower frequencies. It was concluded from this study that skeletal muscles are affected by the disuse of weightlessness early in the period of weightlessness, antigravity muscles seem most affected by weightlessness, and exercise may abrogate the weightlessness effect. It was further concluded that electromyography is a sensitive tool for measuring spaceflight muscle effects.

Lafevers, E. V.↗

Operator performance and localized muscle fatigue in a simulated space vehicle control task

Fourier transforms in a special purpose computer were utilized to obtain power spectral density functions from electromyograms of the biceps brachii, triceps brachii, brachioradialis, flexor carpi ulnaris, brachialis, and pronator teres in eight subjects performing isometric tracking tasks in two directions utilizing a prototype spacecraft rotational hand controller. Analysis of these spectra in general purpose computers aided in defining muscles involved in performing the task, and yielded a derived measure potentially useful in predicting task termination. The triceps was the only muscle to show significant differences in all possible tests for simple effects in both tasks and, overall, was the most consistently involved of the six muscles. The total power monitored for triceps, biceps, and brachialis dropped to minimal levels across all subjects earlier than for other muscles. However, smaller variances existed for the biceps, brachioradialis, brachialis, and flexor carpi ulnaris muscles and could provide longer predictive times due to smaller standard deviations for a greater population range.

Lewis, J. L., Jr.↗

Optimal use of electrophysiological indicators of muscular effort and fatigue

Electromyograms (EMG) from working muscles convey information on effort and fatigue. Their application, e.g., to assess the demands of vehicle control tasks, is complicated by the cooperative action of sets of muscles, by both intrinsic and imposed filtering, and by numerous other sources of variation. Fourier analyses of these noise like signals offer one approach to interpretation; downward spectral shifts accompany fatigue. Techniques are being sought (in both time and frequency domains) for further condensing the wideband EMG signals, while retaining essential information, into a concise 'state vector' usable in comparing control system designs.

Updike, O. L.↗