Search NASASearch

SEARCH · Search NASA

Results for “ELECTRON MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resolving the Electron Plume within a Scanning Electron Microscope

Scanning electron microscopy (SEM), a century-old technique, is today a ubiquitous method of imaging the surface of nanostructures. However, most SEM detectors simply count the number of secondary electrons from a material of interest, and thereby overlook the rich material information contained within them. Here, by simple modifications to a standard SEM tool, we resolve the momentum and energy information on secondary electrons by directly imaging the electron plume generated by the electron beam of the SEM. Leveraging these spectroscopic imaging capabilities, our technique is able to image lateral electric fields across a prototypical silicon p–n junctions and to distinguish differently doped regions, even when buried beyond depths typically accessible by SEM. Intriguingly, the subsurface sensitivity of this technique reveals unexpectedly strong surface band bending within nominally passivated semiconductor structures, providing useful insights for complex layered component designs, in which interfacial dynamics dictate device operation. Further, these capabilities for noninvasive, multimodal probing of complicated electronic components are crucial in today’s electronic manufacturing but is largely inaccessible even with sophisticated techniques. These results show that seemingly simple SEM can be extended to probe complex and useful material properties.

36 MATERIALS SCIENCE

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo

Single Electron Self-coherence and Its Wave/Particle Duality in the Electron Microscope

Intensities in high-resolution phase-contrast images from electron microscopes build up discretely in time by detecting single electrons. A wave description of pulse-like coherent-inelastic interaction of an electron with matter implies a time-dependent coexistence of coherent partial waves. Their superposition forms a wave package by phase decoherence of 0.5 - 1 radian with Heisenbergs energy uncertainty ΔE H = $\hbar$/2 Δt -1 matching the energy loss ΔE of a coherent-inelastic interaction and sets the interaction time Δt. In these circumstances, the product of Planck's constant and the speed of light hc is given by the product of the expression for temporal coherence λ 2 /Δλ and the energy loss ΔE. Experimentally, the self-coherence length was measured by detecting the energy-dependent localization of scattered, plane matter waves in surface proximity exploiting the Goos–Hänchen shift. Chromatic-aberration Cc-corrected electron microscopy on boron nitride (BN) proves that the coherent crystal illumination and phase contrast are lost if the self-coherence length shrinks below the size of the crystal unit cell at ΔE > 200 eV. Finally, in perspective, the interaction time of any matter wave compares with the lifetime of a virtual particle of any elemental interaction, suggesting the present concept of coherent-inelastic interactions of matter waves might be generalizable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O

Magnon spectroscopy in the electron microscope

Abstract The miniaturization of transistors is approaching its limits owing to challenges in heat management and information transfer speed 1 . To overcome these obstacles, emerging technologies such as spintronics 2 are being developed, which make use of the electron’s spin as well as its charge. Local phenomena at interfaces or structural defects will greatly influence the efficiency of spin-based devices, making the ability to study spin-wave propagation at the nanoscale and atomic scale a key challenge 3,4 . The development of high-spatial-resolution tools to investigate spin waves, also called magnons, at relevant length scales is thus essential to understand how their properties are affected by local features. Here we detect bulk THz magnons at the nanoscale using scanning transmission electron microscopy (STEM). By using high-resolution electron energy-loss spectroscopy with hybrid-pixel electron detectors, we overcome the challenges posed by weak signals to map THz magnon excitations in a thin NiO nanocrystal. Advanced inelastic electron scattering simulations corroborate our findings. These results open new avenues for detecting magnons and exploring their dispersions and their modifications arising from nanoscale structural or chemical defects. This marks a milestone in magnonics and presents exciting opportunities for the development of spintronic devices.

Science & Technology - Other Topics

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods

Enabling the Acquisition of Electron Beam-Induced Current (EBIC) Images in Conventional SEM and STEM Instruments

Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING

Progress in the development of an ultrafast pulsed ponderomotive phase plate for cryo-electron tomography

Cryo-electron tomography (cryo-ET) is a powerful modality for resolving cellular structures in their native state. While single-particle cryo-electron microscopy excels in determining protein structures purified from recombinant or endogenous sources due to an abundance of particles, weak contrast issues are accentuated in cryo-ET by low copy numbers in crowded cellular milieux. Continuous laser phase plates offer improved contrast in cryo-ET; however, their implementation demands exceptionally high-peak optical intensities. Instead, a novel experimental approach to enhance contrast in cryo-ET is to manipulate the phase of scattered pulsed electrons using ultrafast pulsed photons. Here, we outline the experimental design of a proof-of-concept electron microscope and demonstrate synchronization between electron packets and laser pulses. Furthermore, we show ultrabright photoemission of electrons from an alloy field emission tip using femtosecond ultraviolet pulses. These experiments pave the way toward exploring the utility of the ponderomotive effect using pulsed radiation to increase phase contrast in cryo-ET of subcellular protein complexes in situ, thus advancing the field of cell biology.

Du, Daniel X. [Columbia Univ., New York, NY (Unite

Effect of stress on Laves phase precipitation in creep ruptured Grade 92 ferritic martensitic steel characterized by a novel accessible method

At high temperature conditions relevant to fossil and nuclear energy plants, Laves phase (Fe 2 X, X=Mo, W) precipitation is observed in common ferritic martensitic (FM) structural steels, with various reported effects on creep behavior. Despite being valuable metrics to correlate with mechanical properties and other precipitate phases, the volume fraction and number density of Laves phase precipitates has been difficult to quantify accurately using common techniques such as transmission electron microscopy (TEM) due to the relatively large size (∼0.25 μm) and low number density (∼10 11 cm −3 ) of Laves precipitates. Here, to address this characterization challenge, we developed and demonstrated a high-throughput and widely accessible method to quantify the volume fraction and number density of the Laves phase based on scanning electron microscope (SEM) images with a backscattered electron signal and the information depth (ID) of backscattered electrons. We applied this new technique in creep ruptured Grade 92 FM steel to study the effect of Laves phase on creep properties and determine the influence of stress on Laves phase precipitation. The quantitative accuracy of the SEM-based volume fraction and number density values was verified using synchrotron high energy X-ray diffraction and serial sectioning tomography. Stress did not significantly affect the Laves phase size or volume fraction during creep testing at 550 – 650°C and stress levels of 90 – 260 MPa (vs. unstressed conditions). Conversely, a moderate but statistically significant stress-enhanced increase in Laves phase number density, corresponding to an increase in nucleation rate, occurred during creep exposure above 110 MPa.

Creep

In situ self-ion (Fe + ) irradiation of ODS-FeCrAl alloy fuel cladding materials with different Cr contents: The early stages of Cr-rich α’ phase precipitation

Oxide-dispersion-strengthened FeCrAl (ODS-FeCrAl) alloys are candidate accident-tolerant fuel cladding materials for light water reactors because they demonstrate satisfactory resistance to materials degradation effects such as high-temperature oxidation, radiation-induced swelling, and creep. Their perspective deployment to market is challenged, however, by their inherent susceptibility to irradiation embrittlement caused by the precipitation of the brittle Cr-rich α’ phase at relatively low temperatures (≤475 °C). This work used in situ self-ion irradiation (150 keV Fe + ) in a transmission electron microscope to elucidate the early stages of Cr-rich α’ phase precipitation in three candidate ODS-FeCrAl alloy fuel cladding materials with different Cr contents (10, 12, and 20 wt.%) and microstructures. The early stages of the process resulting in the precipitation of the Cr-rich α’ phase in these three ODS-FeCrAl alloys under Fe + irradiation were investigated at room temperature and 300 °C up to total fluences of 1.7 × 10 15 ions·cm -2 (2 dpa) and 3.4 × 10 15 ions·cm -2 (4 dpa), using three damage dose rates (5 × 10 –5 , 3.3 × 10 –4 , and 2 × 10 –3 dpa·s -1 ). Post-irradiation examination via scanning transmission electron microscopy, energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy suggested that the precipitation of the Cr-rich α’ phase might be promoted by the phase separation of the alloy matrix into Cr-rich and Fe-rich regions. Interestingly, oxygen impurities segregated preferentially in the Cr-rich regions, possibly promoting the radiation-assisted formation of the Cr-rich α’ phase. α’ phase precipitation was more pronounced at room temperature when compared to 300 °C, and it was clearly promoted by the progressive increase in the Cr content of the ODS-FeCrAl alloy.

36 MATERIALS SCIENCE

Crystal Orientation and Defect Mapping in Electron-Beam-Sensitive Zeolites with Near-Axis Transmission Kikuchi Diffraction

Porous materials are vital in catalysis, energy conversion, and environmental remediation. Understanding structural heterogeneity in zeolites is key to linking synthesis, framework intergrowths, and catalytic performance, yet current methods for phase identification and spatial mapping lack sufficient resolution or throughput. We present a high-throughput approach using near-axis transmission Kikuchi diffraction in a scanning electron microscope, achieving high phase and spatial resolution for electron-beam-sensitive zeolites, including ZSM-5 and, for the first time, Zeolite A. Here, this method enables direct visualization of intergrowth features that critically affect catalytic and adsorption behavior, bridging the gap between ensemble-averaged X-ray diffraction and high-resolution but low-throughput transmission electron microscopy. Combining nanoscale mapping with statistical sampling is highly suited for machine-learning pipelines guiding new structure function understanding and could be extended to other beam-sensitive porous materials such as metal–organic or covalent–organic frameworks.

crystallography