Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON VOLTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Femtosecond mega-electron-volt electron microdiffraction

To understand and control the basic functions of physical, chemical and biological processes from micron to nano-meter scale, an instrument capable of visualizing transient structural changes of inhomogeneous materials with atomic spatial and temporal resolutions, is required. One such technique is femtosecond electron microdiffraction, in which a short electron pulse with femtosecond-scale duration is focused into a micron-scale spot and used to obtain diffraction images to resolve ultrafast structural dynamics over a localized crystalline domain. In this letter, we report the experimental demonstration of time-resolved mega-electron-volt electron microdiffraction which achieves a 5 μm root-mean-square (rms) beam size on the sample and a 110 fs rms temporal resolution. Using pulses of 10k electrons at 4.2 MeV energy with a normalized emittance 3 nm-rad, we obtained high quality diffraction from a single 10 μm paraffin ( C 44 H 90 ) crystal. The phonon softening mode in optical-pumped polycrystalline Bi was also time-resolved, demonstrating the temporal resolution limits of the instrument. In conclusion, this new characterization capability will open many research opportunities in material and biological sciences.

36 MATERIALS SCIENCE↗

Photodissociation of aqueous I3− observed with liquid-phase ultrafast mega-electron-volt electron diffraction

Developing femtosecond resolution methods for directly observing structural dynamics is critical to understanding complex photochemical reaction mechanisms in solution. We have used two recent developments, ultrafast mega-electron-volt electron sources and vacuum compatible sub-micron thick liquid sheet jets, to enable liquid-phase ultrafast electron diffraction (LUED). We have demonstrated the viability of LUED by investigating the photodissociation of tri-iodide initiated with a 400 nm laser pulse. This has enabled the average speed of the bond expansion to be measured during the first 750 fs of dissociation and the geminate recombination to be directly captured on the picosecond time scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction

Abstract A real-time, nondestructive, Bragg-diffracted electron beam energy, energy-spread and spatial-pointing jitter monitor is experimentally verified by encoding the electron beam energy and spatial-pointing jitter information into the mega-electron-volt ultrafast electron diffraction pattern. The shot-to-shot fluctuation of the diffraction pattern is then decomposed to two basic modes, i.e., the distance between the Bragg peaks as well as its variation (radial mode) and the overall lateral shift of the whole pattern (drift mode). Since these two modes are completely decoupled, the Bragg-diffraction method can simultaneously measure the shot-to-shot energy fluctuation from the radial mode with 2·10 −4 precision and spatial-pointing jitter from the drift mode having wide measurement span covering energy jitter range from 10 −4 to 10 −1 . The key advantage of this method is that it allows us to extract the electron beam energy spread concurrently with the ongoing experiment and enables online optimization of the electron beam especially for future high charge single-shot ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) experiments. Furthermore, real-time energy measurement enables the filtering process to remove off-energy shots, improving the resolution of time-resolved UED. As a result, this method can be applied to the entire UED user community, beyond the traditional electron beam diagnostics of accelerators used by accelerator physicists.

43 PARTICLE ACCELERATORS↗

Femtosecond gas-phase mega-electron-volt ultrafast electron diffraction

The development of ultrafast gas electron diffraction with nonrelativistic electrons has enabled the determination of molecular structures with atomic spatial resolution. It has, however, been challenging to break the picosecond temporal resolution barrier and achieve the goal that has long been envisioned—making space- and-time resolved molecular movies of chemical reaction in the gas-phase. Recently, an ultrafast electron diffraction (UED) apparatus using mega-electron-volt (MeV) electrons was developed at the SLAC National Accelerator Laboratory for imaging ultrafast structural dynamics of molecules in the gas phase. The SLAC gas-phase MeV UED has achieved 65 fs root mean square temporal resolution, 0.63 Å spatial resolution, and 0.22 Å−1 reciprocal-space resolution. Such high spatial-temporal resolution has enabled the capturing of real-time molecular movies of fundamental photochemical mechanisms, such as chemical bond breaking, ring opening, and a nuclear wave packet crossing a conical intersection. In this paper, the design that enables the high spatial-temporal resolution of the SLAC gas phase MeV UED is presented. The compact design of the differential pump section of the SLAC gas phase MeV UED realized five orders-of-magnitude vacuum isolation between the electron source and gas sample chamber. The spatial resolution, temporal resolution, and long-term stability of the apparatus are systematically characterized.

74 ATOMIC AND MOLECULAR PHYSICS↗

Liquid-phase mega-electron-volt ultrafast electron diffraction

The conversion of light into usable chemical and mechanical energy is pivotal to several biological and chemical processes, many of which occur in solution. To understand the structure–function relationships mediating these processes, a technique with high spatial and temporal resolutions is required. Here, we report on the design and commissioning of a liquid-phase mega-electron-volt (MeV) ultrafast electron diffraction instrument for the study of structural dynamics in solution. Limitations posed by the shallow penetration depth of electrons and the resulting information loss due to multiple scattering and the technical challenge of delivering liquids to vacuum were overcome through the use of MeV electrons and a gas-accelerated thin liquid sheet jet. To demonstrate the capabilities of this instrument, the structure of water and its network were resolved up to the 3rd hydration shell with a spatial resolution of 0.6 Å; preliminary time-resolved experiments demonstrated a temporal resolution of 200 fs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A terahertz pump mega-electron-volt ultrafast electron diffraction probe apparatus at the SLAC Accelerator Structure Test Area facility

Here, we describe a new experimental setup capable of measuring structural dynamics following intense terahertz excitation. This system, developed at the SLAC Accelerator Structure Test Area facility, uses a high-energy ultrafast laser to produce intense terahertz pulses and femtosecond electron bunches that are accelerated to mega-electron-volt kinetic energies. The focused terahertz pulses have electric fields in excess of 600 kV/cm, and the resulting structural dynamics can be followed by electron diffraction. We also present some examples demonstrating its implementation where interactions between the THz pulses and the electron bunch are used to characterize the spatial and temporal characteristics of the THz field.

42 ENGINEERING↗

Tracking dissociation pathways of nitrobenzene via mega-electron-volt ultrafast electron diffraction

As the simplest nitroaromatic compound, nitrobenzene is an interesting model system to explore the rich photochemistry of nitroaromatic compounds. Previous investigations of nitrobenzene's photochemical dynamics have probed structural and electronic properties. These investigations paint, at times, a convoluted and sometimes contradictory description of the photochemical landscape. Here, we investigate the ultrafast dynamics of nitrobenzene triggered by photoexcitation at 267 nm for the first time using a structural probe with femtosecond time resolution. Our probe complements previous measurements of nitrobenzene's electronic structure evolution and aids in determining the photochemical dynamics with less ambiguity. We employ megaelectronvolt ultrafast electron diffraction to follow nitrobenzene's structural evolution within the first 5 ps after photoexcitation. We observe ground state recovery within 160 ± 60 fs through nonadiabatic dynamics. Based on comparisons of the experimental signal with molecular dynamics simulations, we exclude a significant population of the triplet manifold. Furthermore, we do not observe fragmentation of nitrobenzene within the investigated time window, which indicates that previously observed photofragmentation reactions take place in the vibrationally 'hot' ground state on timescales considerably beyond 5 ps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Forecasting Megaelectron-Volt Electrons Inside Earth's Outer Radiation Belt: PreMevE 2.0 Based on Supervised Machine Learning Algorithms

We present the recent progress in upgrading a predictive model for megaelectron-volt (MeV) electrons inside the Earth's outer Van Allen belt. This updated model, called PreMevE 2.0, provides improved forecasts, particularly at outer L-shells, by adding upstream solar wind speeds to the model's input parameter list that originally includes precipitating electrons observed at low Earth orbits and MeV electron fluxes in situ measured by a geosynchronous satellite. Furthermore, based on several kinds of linear and artificial neural networks algorithms, a list of models was constructed, trained, validated, and tested with 42-month MeV electron observations from Van Allen Probes. Out-of-sample test results from these models show that, with optimized model hyperparameters and input parameter combinations, the top performer from each category of models has the similar capability of making reliable 1-day (2-day) forecasts of 1-MeV electron flux distributions with performance efficiency values ~0.87 (~0.82) averaged over the L-shell range of 2.8–6.6, significantly outperforming the previous version of PreMevE particularly at L-shells > ~4.5. Interestingly, the linear regression model is often the most successful when compared to other models, which suggests the relationship between dynamics of trapped 1-MeV electrons and precipitating electrons is dominated by linear components. Results also show that PreMevE 2.0 can reasonably well predict the onsets of MeV electron events in 2-day forecasts. PreMevE 2.0 is designed to be driven by observations from longstanding space infrastructure to make high-fidelity forecasts for MeV electrons, thus can be an invaluable space weather forecasting tool for the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute differential cross sections for electron capture and loss by kilo-electron-volt hydrogen atoms

This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H2, N2, O2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02-2 deg, with an angular, resolution of 0.02 deg. The high angular resolution allows observation of the structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.

Smith, G. J.↗