Integrated Strategies for Overcoming Resolution Limits in Electron Beam Lithography of Chemically Amplified Resists

Electron beam lithography (EBL) of chemically amplified resists (CARs) faces fundamental challenges, including stochastic electron scattering and acid diffusion, that limit resolution and reproducibility. Using SU-8 as a model CAR, this study systematically investigated complementary strategies to address these challenges, combining multipass exposure, proximity effect correction (PEC) with midrange correction factors, base quencher incorporation, and post-exposure bake (PEB) suppression. Monte Carlo simulations and calibrated PEC modeling revealed that extending the point spread function to include a midrange scattering component significantly improved critical dimension (CD) control across varying pattern densities, correcting deviations that conventional two-term PEC failed to capture. Multipass exposure, particularly 4-pass writing with a 25% offset, redistributed the dose to average stochastic beam and scattering fluctuations, reducing line-width roughness by more than 50% and yielding more uniform nanoscale features. Photoacid confinement was investigated by adding urea as a base quencher, which successfully reduced acid diffusion but introduced substantial sensitivity penalties without improving ultimate resolution or Z-factor performance, underscoring the trade-offs of chemical versus physical confinement. Suppressing PEB most directly minimized acid diffusion, resulting in improved Z-factors and reproducible 30 nm half-pitch dense line/space patterns. Overall, these results demonstrated that PEC with midrange correction, multipass strategies, quencher additives, and PEB-free processing addresses different aspects of the EBL process window and that their integration provides a comprehensive framework for managing stochastic scattering, diffusion, and chemical amplification effects. This framework advances dense nanoscale patterning in CARs and establishes guiding principles for optimizing resist design and process strategies in high-resolution EBL and potentially other advanced lithographies, such as extreme ultraviolet (EUV) lithography.

36 MATERIALS SCIENCE

Coherent Control over Nuclear Hyperpolarization Using an Optically Initializable Chromophore-Radical System

Chromophore radicals (CR) are emerging as important components for molecular quantum information science (QIS), especially in the context of quantum sensing. Here, we demonstrate that the optically hyperpolarized electrons in a 1,6,7,12-tetrakis(4-tert-butylphenoxy)-perylene-3,4,9,10-bis(dicarboximide) (tpPDI) covalently linked to a partially deuterated 1,3-bis(diphenylene)-d 16 -2-phenylallyl radical (BDPA-d 16 ) can be coherently manipulated via pulsed dynamic nuclear polarization (DNP) methods to transfer polarization to nuclear spins and back. Under light illumination at 85 K, electron hyperpolarization in BDPA is enhanced 2.1- to 2.4-fold over thermal polarization and lasts for more than 100 ms. By applying nuclear orientation via electron spin-locking (NOVEL) DNP, this optically amplified electron hyperpolarization was successfully transferred to a 1 H nuclear spin within the CR system and efficiently returned to the electron spin for readout via reverse-NOVEL. The NOVEL transfer efficiency of 65% amounts to a 688-fold nuclear spin hyperpolarization of the target nuclear spin, considering the 2.1-fold electron spin hyperpolarization. This reversible coherent manipulation of hyperpolarization transfer highlights the utility of CR systems to initialize and read out nuclear spin states in a disordered matrix at moderate cryogenic temperatures. Coupled with CRs’ environmental compatibility, tunability, and precise state initialization, these results highlight the promising role of nuclear spins in CRs for QIS applications, including quantum sensing and memory.

charge transfer

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers

Fermilab 2025 Summer Internship: Repairing Pre-Amplifiers with Mu2e Electronics Installation Team

The author spent nine weeks over summer 2025 working on the tracker electronics installation team for the Mu2e experiment. One of her main responsibilities was repairing high voltage (HV) and calibration (Cal) pre-amplifiers (pre-amps). During installation, the fragile wires connecting the two sockets to the pre-amp board must be bent, often leading to breakage. During production, the sockets and wires were initially soldered to the board at UC Berkely, then the whole pre-amp was coated in parylene before transport to Fermilab. The interns were able to expedite the repairs, and thus whole installation process, by using an alternative method on-site with epoxy. Another task they were responsible for, not included in the original project specifications, was attaching copper clips to specific vias on the Cals to reduce noise. The talk will give listeners insight into the daily problem-solving required by the novel technologies in the Mu2e project. The author would like to acknowledge her fellow Monmouth College undergraduate interns, Lizzie Durfee and Gianna Maughan, advisor and PI of the DOE RENEW Grant Dr. Christopher G. Fasano, and the Mu2e team lead by co-spokesperson Dr. Bob Bernstein and tracker L2 manager Dr. Brendan Kiburg.

de Zwart, Bronte [Monmouth Coll.]

Electron correlation and incipient flat bands in the Kagome superconductor CsCr 3 Sb 5

Correlated kagome materials exhibit a compelling interplay between lattice geometry, electron correlation, and topology. In particular, the flat bands near the Fermi level provide a fertile playground for novel many-body states. Here we investigate the electronic structure of CsCr 3 Sb 5 using high-resolution angle-resolved photoemission spectroscopy and ab-initio calculations. Our results suggest that Cr 3d electrons are intrinsically incoherent, showing strong electron correlation amplified by Hund’s coupling. Notably, we identify incipient flat bands close to the Fermi level, which are expected to significantly influence the electronic properties of the system. Across the density-wave-like transition at 55 K, we observe a drastic enhancement of the electron scattering rate, which aligns with the semiconducting-like property at high temperatures. These findings establish CsCr 3 Sb 5 as a strongly correlated Hund’s metal with incipient flat bands near the Fermi level, which provides an electronic basis for understanding its novel properties compared to the weakly correlated AV 3 Sb 5 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Bldg. 7930 Cell G Neutron Detector New Electronics Testing

The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.

Taylor, Neil [Oak Ridge National Laboratory (ORNL)

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A simulation framework for evaluating electronic order workflows in integrated health records

Electronic health record (EHR) systems are critical to modern healthcare delivery, yet the dynamic workflows that govern electronic order processing remain underexplored. Inefficiencies in these digital pathways can cause delays in care, repetitive workloads, and even patient harm. This study presents a discrete-event simulation framework used to reconstruct and evaluate EHR-based order workflows in a large integrated healthcare system. Using real-world data extracted from the Veterans Health Administration’s Corporate Data Warehouse, the authors mapped order events to standardized state transitions and modeled their progression across different facilities of varying complexity levels. After being calibrated with empirical distributions of transition times and validated against observed time-in-system metrics, the simulation demonstrates close alignment with historical performance. Scenario analyses reveal that resource capacity constraints significantly amplify the impact of electronic order surges, which are reflected in the disproportionate growth in backlogs and processing delays. Adjustments in transition probabilities further increased recirculation and extended workflow paths. Network-based analysis identified Reserved, InProgress, and Completed as structurally critical states that function as hubs within the process network but the transitions in-between also act as major bottlenecks. These results showcased the effectiveness of simulation-based approaches in monitoring EHR order processing performance and evaluating consequences of workflow changes on healthcare network resources planning. The proposed simulation framework provides a scalable data-driven tool to support operational decision-making and improve the efficiency of electronic order management in complex healthcare environments.

Engineering

X-ray free-electron lasing in a flying-focus undulator

Laser-driven free-electron lasers (LDFELs) replace magnetostatic undulators with the electromagnetic fields of a laser pulse. Because the undulator period is half the wavelength of the laser pulse, LDFELs can amplify X rays using lower electron energies and over shorter interaction lengths than a traditional free-electron laser. In LDFELs driven by conventional laser pulses, the undulator uniformity required for high gain necessitates large laser-pulse energies. Here, we show that a flying-focus pulse provides the undulator uniformity required to reach high gain with a substantially lower energy than a conventional pulse. The flying-focus pulse features an intensity peak that travels in the opposite direction of its phase fronts. This enables an LDFEL configuration where an electron beam collides head-on with the phase fronts and experiences a near-constant undulator strength as it co-propagates with the intensity peak. Three-dimensional simulations of this configuration demonstrate the generation of megawatts of coherent X-ray radiation with 20 × less energy than a conventional laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)

Sensing Few Electrons Floating on Helium with High-Electron-Mobility Transistors

We report on low-frequency measurements of few electrons floating on superfluid helium using a bespoke cryogenic cascode amplifier circuit built with off-the-shelf GaAs high-electron-mobility transistors (HEMTs). We integrate this circuit with a charge-coupled device (CCD) to transport the electrons on helium and characterize its performance. Here, we show that this circuit has a signal-to-noise ratio (SNR) of ~ 2 $\frac{e}{√Hz}$ at 102 kHz, an order of magnitude improvement from previous implementations, and provides a compelling alternative to few electron sensing with high-frequency resonators.

Charge-Coupled Devices

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors

Three-dimensional higher-order saddle-point-induced flatbands in Co-based kagome metals

The saddle point (Van Hove singularity) exhibits a divergent density of states in two-dimensional systems, leading to fascinating phenomena such as strong correlations and unconventional superconductivity, yet it is seldom observed in three-dimensional (3D) systems. In this work we find two types of 3D higher-order saddle points (HOSPs) in emerging 3D kagome metals YbCo 6⁢ Ge 6 and MgCo 6 ⁢Ge 6 . Both HOSPs exhibit a singularity in their density of states, which is significantly enhanced compared to the ordinary saddle point. The HOSP near the Fermi energy generates a flatband extending a large area in the Brillouin zone, potentially amplifying the correlation effect and fostering electronic instabilities. Two types of HOSPs exhibit distinct robustness upon element substitution and lattice distortions in these kagome compounds. Our work paves the way for engineering exotic band structures, such as saddle points and flatbands, and exploring interesting phenomena in Co-based kagome materials.

36 MATERIALS SCIENCE

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Large exciton binding energy in a bulk van der Waals magnet from quasi-1D electronic localization

Excitons, bound electron-hole pairs, influence the optical properties in strongly interacting solid-state systems and are typically most stable and pronounced in monolayer materials. Bulk systems with large exciton binding energies, on the other hand, are rare and the mechanisms driving their stability are still relatively unexplored. Here, we report an exceptionally large exciton binding energy in single crystals of the bulk van der Waals antiferromagnet CrSBr. Utilizing state-of-the-art angle-resolved photoemission spectroscopy and self-consistent ab-initio GW calculations, we present direct spectroscopic evidence supporting electronic localization and weak dielectric screening as mechanisms contributing to the amplified exciton binding energy. Furthermore, we report that surface doping enables broad tunability of the band gap offering promise for engineering of the optical and electronic properties. Our results indicate that CrSBr is a promising material for the study of the role of anisotropy in strongly interacting bulk systems and for the development of exciton-based optoelectronics.

36 MATERIALS SCIENCE

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)