Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Modular 512-Channel Neural Signal Acquisition ASIC for High-Density 4096 Channel Electrophysiology

The complexity of information processing in the brain requires the development of technologies that can provide spatial and temporal resolution by means of dense electrode arrays paired with high-channel-count signal acquisition electronics. In this work, we present an ultra-low noise modular 512-channel neural recording circuit that is scalable to up to 4096 simultaneously recording channels. The neural readout application-specific integrated circuit (ASIC) uses a dense 8.2 mm × 6.8 mm 2D layout to enable high-channel count, creating an ultra-light 350 mg flexible module. The module can be deployed on headstages for small animals like rodents and songbirds, and it can be integrated with a variety of electrode arrays. The chip was fabricated in a TSMC 0.18 µm 1.8 V CMOS technology and dissipates a total of 125 mW. Each DC-coupled channel features a gain and bandwidth programmable analog front-end along with 14 b analog-to-digital conversion at speeds up to 30 kS/s. Additionally, each front-end includes programmable electrode plating and electrode impedance measurement capability. We present both standalone and in vivo measurements results, demonstrating the readout of spikes and field potentials that are modulated by a sensory input.

47 OTHER INSTRUMENTATION↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The 6-minute walk test predicts mortality in a pulmonary nontuberculous mycobacteria-predominant bronchiectasis cohort

Background: Bronchiectasis is a chronic lung condition frequently associated with nontuberculous mycobacteria pulmonary (NTM) disease. Persons with these conditions are at increased risk of mortality. Patient reported outcome (PRO) instruments and the 6-minute walk test (6MWT) have been shown to predict mortality for several lung conditions, but these measures have not been fully evaluated for bronchiectasis and NTM. Methods: We conducted a retrospective cohort study among adult patients enrolled in a natural history study of bronchiectasis at the National Heart, Lung, and Blood Institute. Electronic medical records were queried for demographic, clinical, microbiologic, radiographic, and PRO instrument data: St. George’s Respiratory Questionnaire (SGRQ), Medical Research Council Dyspnea Scale, and the Pulmonary Symptom Severity Score (PSSS). The study baseline date was defined as the patient’s first visit after January 1st, 2015 with a SGRQ or 6MWT completed. Follow-up was defined as the interval between the study baseline visit and date of death or December 31st, 2019. Sex-stratified Cox proportional-hazards regression was conducted to identify predictors of mortality. Separate models were run for each PRO and 6MWT measure, controlling for age, body mass index (BMI), fibrocavitary disease status, and M. abscessus infection. Results: In multivariable Cox proportional-hazards regression models, the PSSS-severity (aHR 1.29, 95% CI 1.04–1.59), the 6MWT total distance walked (aHR 0.938, 95% CI 0.896–0.981) and distance saturation product (aHR 0.930, 95% CI 0.887–0.974) independently predicted mortality. In addition, BMI was significantly predictive of mortality in all models. Conclusions: The 6MWT and a PRO instrument capturing symptom severity are independently predictive of mortality in our cohort of bronchiectasis patients.

6-minute walk test↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Quantitative approaches for multiscale structural analysis with atomic resolution electron microscopy

Atomic-resolution imaging with scanning transmission electron microscopy is a powerful tool for characterizing the nanoscale structure of materials, in particular features such as defects, local strains, and symmetry-breaking distortions. In addition to advanced instrumentation, the effectiveness of the technique depends on computational image analysis to extract meaningful features from complex datasets recorded in experiments, which can be complicated by the presence of noise and artifacts, small or overlapping features, and the need to scale analysis over large representative areas. Here, we present image analysis approaches which synergize real and reciprocal space information to efficiently and reliably obtain meaningful structural information with picometer scale precision across hundreds of nanometers of material from atomic-resolution electron microscope images. Damping superstructure peaks in reciprocal space allows symmetry-breaking structural distortions to be disentangled from other sources of inhomogeneity and measured with high precision. Real-space fitting of the wavelike signals resulting from Fourier filtering enables absolute quantification of lattice parameter variations and strain, as well as the uncertainty associated with these measurements. Implementations of these algorithms are made available as an open source python package.

36 MATERIALS SCIENCE↗

Doping engineering: Next step toward room temperature performance of terahertz quantum cascade lasers

We hereby offer a comprehensive analysis of various factors that could potentially enable terahertz quantum cascade lasers (THz QCLs) to achieve room temperature performance. We thoroughly examine and integrate the latest findings from recent studies in the field. Our work goes beyond a mere analysis; it represents a nuanced and comprehensive exploration of the intricate factors influencing the performance of THz QCLs. Through a comprehensive and holistic approach, we propose novel insights that significantly contribute to advancing strategies for improving the temperature performance of THz QCLs. This all-encompassing perspective allows us not only to present a synthesis of existing knowledge but also to offer a fresh and nuanced strategy to improve the temperature performance of THz QCLs. We draw new conclusions from prior works, demonstrating that the key to enhancing THz QCL temperature performance involves not only optimizing interface quality but also strategically managing doping density, its spatial distribution, and profile. This is based on our results from different structures, such as two experimentally demonstrated devices: the spit-well resonant-phonon and the two-well injector direct-phonon schemes for THz QCLs, which allow efficient isolation of the laser levels from excited and continuum states. In these schemes, the doping profile has a setback that lessens the overlap of the doped region with the active laser states. Our work stands as a valuable resource for researchers seeking to gain a deeper understanding of the evolving landscape of THz technology. Furthermore, we present a novel strategy for future endeavors, providing an enhanced framework for continued exploration in this dynamic field. This strategy should pave the way to potentially reach higher temperatures than the latest records reached for T max of THz QCLs.

47 OTHER INSTRUMENTATION↗

AMIA KDDM Working Group Collaborative Workshop: Enriching Electronic Health Records with Social Determinants of Health to Improve Outcomes and Health Equity

Prior research has demonstrated that social determinants of health (SDoH) are major drivers of health outcomes and contributors to widespread health inequities. It was estimated that, in the United States, SDoH could be responsible for up to 40% of all preventable deaths, significantly higher than the 10-15% for which better medical care is responsible. Public health interventions that target SDoH are instrumental for improving health outcomes and reducing long-standing health inequities. Currently, most mainstream EHR vendors have implemented SDoH screeners in their EHR systems. However, the utility of the screeners is low, rendering patient-level SDoH still widely unavailable in the structured fields. SDoH are sometimes mentioned in free-text clinical notes (e.g., social context section) where natural language processing (NLP) can be applied to extract relevant information. Contextual-level SDoH can be identified from multiple data sources, many of which are publicly available and spatiotemporally linked to EHR data. As such, there is an opportunity for the KDDM research community to create innovative solutions to draw meaningful insights by creating and using rich data with SDoH to improve health outcomes while reducing disparities. In this workshop organized by AMIA Knowledge Discovery and Data Mining Working Group (AMIA KDDM WG), we will invite world-leading experts from academia, national laboratories, and life science industry with varied backgrounds in biomedical informatics, epidemiology, data science, machine learning, natural language processing, and pediatric cardiology to discuss the best practice of capturing, standardizing, and using SDoH information in various applications aiming at improving outcomes and health equity.

He, Zhe↗

Two-well injector direct-phonon terahertz quantum cascade lasers

We present an experimental study on a terahertz quantum cascade laser (THz QCL) design that combines both two-well injector and direct-phonon scattering schemes, i.e., a so-called two-well injector direct-phonon design. As a result of the two-well injector direct-phonon scheme presented here, the lasers benefit from both a direct phonon scattering scheme for the lower laser level depopulation and a setback for the doping profile that reduces the overlap of the doped region with active laser states. Additionally, our design also has efficient isolation of the active laser levels from excited and continuum states as indicated by negative differential resistance behavior all the way up to room temperature. This scheme serves as a good platform for improving the temperature performance of THz QCLs as indicated by the encouraging temperature performance results of the device with a relatively high doping level of 7.56 × 10 10 cm −2 and T max ∼ 167 K. With the right optimization of the molecular beam epitaxy growth and interface quality, the injection coupling strength, and the doping density and its profile, the device could potentially reach higher temperatures than the latest records reached for the maximum operating temperature (T max ) of THz QCLs.

47 OTHER INSTRUMENTATION↗

Record quantum efficiency from strain compensated superlattice GaAs/GaAsP photocathode for spin polarized electron source

Photocathodes based on GaAs and other III–V semiconductors are capable of producing highly spin-polarized electron beams. GaAs/GaAsP superlattice photocathodes exhibit high spin polarization; however, the quantum efficiency (QE) is limited to 1% or less. To increase the QE, we fabricated a GaAs/GaAsP superlattice photocathode with a Distributed Bragg Reflector (DBR) underneath. This configuration creates a Fabry–Pérot cavity between the DBR and GaAs surface, which enhances the absorption of incident light and, consequently, the QE. These photocathode structures were grown using molecular beam epitaxy and achieved record quantum efficiencies exceeding 15% and electron spin polarization of about 75% when illuminated with near-bandgap photon energies.

47 OTHER INSTRUMENTATION↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaching Angstrom-Scale Resolution in Lithography Using Low-Molecular-Mass Resists (<500 Da)

Resists that enable high-throughput and high-resolution patterning are essential in driving the semiconductor technology forward. The ultimate patterning performance of a resist in lithography is limited because of the trade-off between resolution, line-width roughness, and sensitivity; improving one or two of these parameters typically leads to a loss in the third. As the patterned feature sizes approach angstrom scale, the trade-off between these three metrics becomes increasingly hard to resolve and calls for a fundamental rethinking of the resist chemistry. Low-molecular-mass monodispersed metal-containing resists of high atom economy can provide not only very high resolution but also very low line-width roughness without sacrificing sensitivity. Here we describe a modular metal-containing resist platform (molecular mass <500 Da) where a molecular resist consists of just two components: a metal and a radical initiator bonded to it. This simple system not only is amenable to high-resolution electron beam lithography (EBL) and extreme ultraviolet lithography (EUVL) but also unites them mechanistically, giving a consolidated perspective of molecular and chemical processes happening during exposure. Irradiation of the resist leads to the production of secondary electrons that generate radicals in the initiator bonded to metal. This brings about an intramolecular rearrangement and causes solubility switch in the exposed resist. We demonstrate record 1.9–2.0 nm isolated patterns and 7 nm half-pitch dense line-space features over a large area using EBL. With EUVL, 12 nm half-pitch line-space features are shown at a dose of 68 mJ/cm 2 . In both of these patterning techniques, the line-width roughness was found to be ≤2 nm, a record low value for any resist platform, also leading to a low-performance trade-off metric, Z factor, of 0.6 × 10 –8 mJ·nm 3 . With the ultimate resolution limited by instrumental factors, potential patterning at the level of a unit cell can be envisaged, making low-molecular-mass resists best poised for angstrom-scale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Erratum: Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV [Phys. Rev. Lett. 116, 122301 (2016)]

We previously reported jet-production rates in 𝑝 + 𝑝 and 𝑑 + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Subsequently, we found that electronic noise in the electromagnetic calorimeter was not completely removed by the tower-timing cuts used in the analysis. We have conducted an independent re-analysis of the data that eliminated noisy towers by removing them completely from the analysis. These cuts remove any contributions from instrumental noise, but reduce the overall acceptance for electromagnetic clusters by ≈16% and hence the overall statistical power of the data. Finally, this re-analysis found that instrumental noise in the electromagnetic calorimeter led to an artificial increase in the jet yield for both the 𝑝 + 𝑝 and 𝑑 + Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗